NUPOWER C30R01 PA SPECIFICATIONS
The subsequent tables in this section outline the NuPower C30R01’s performance specifications.
Table 1: NuPower C30R01 Electrical Specifications
Parameter
Specification
Frequency Range
5030 to 5090 MHz
RF Output Power
30 Watts (min)
Output Power @ 1 dB Compression
28 dBm @ 5030 MHz
29 dBm @ 5060 MHz
29 dBm @ 5090 MHz
RF Gain
45 dB
Input VSWR
2.3 (typ)
Output Mismatch
(No Damage)
10:1
Nominal Input Drive Level
0 dBm
Maximum Input Drive Level
(No damage)
+15 dBm
Harmonic
2
nd
: ≤
-70 dBc
3
rd
: ≤
-70 dBc
Third Order Intercept Point
(Two tone test at 1 MHz spacing,
Pout = 20 dBm / tone)
40 dBm @ 5.03 GHz
Switching Speed
2 µS
Operating Voltage
+27 to +30 VDC
Operating Current
4.1 A @ +28 VDC (typ)
Module Efficiency
30%
Power Amplifier Enable
RF Enable Grounded
Impedance
50
Ω