background image

NuPower

TM

 12D05A User Manual    

 

 

Rev 1.1 

 

3

 

SETUP AND OPERATION 

This  section  provides  specific  details  for  proper  operation  of  the  NuPower  12D05A  module.  Following 
these guidelines will prevent damage to the power amplifier or external equipment. 

3.1

 

POWER SUPPLY REQUIREMENTS 

To operate the NuPower 12D05A, ensure that the power supply has adequate overhead to source the 
current demand of the RF power amplifier. The power supply source must provide a typical voltage of 
+28 VDC with greater than 3 amps capability.  

3.2

 

CONNECTING A PROPER LOAD TO THE ANTENNA TERMINAL 

To prevent damage to the PA, the antenna terminal must be terminated into a 50 

Ω

 load. Examples of a 

proper load include: 
 

 

Directly  connecting  to  an  antenna  specified  for  the  frequency  range  (800  MHz  to  2000  MHz). 
Connecting to an inappropriate antenna may result in damage to the PA module.  

 

Connecting to a proper antenna through a 50 

Ω

 transmission line or coaxial cable. Avoid using 

damaged cables or corroded connectors while attaching the unit to an antenna. 

 

Terminating  the  antenna  terminal  into  a  50 

Ω

  power  attenuator  with  minimum  20  dB 

attenuation. 

 

Connecting to a load capable of dissipating the RF power from the PA module. Loads capable of 
handling 50 Watts (min) are recommended.  

3.3

 

POWERING‐UP THE NUPOWER 12D05A 

The NuPower 12D05A must be terminated to a proper load before power is applied. Refer to Section 3.2 
for the specifications of the proper load. After the PA is properly terminated, the interface cable can be 
connected to the unit and power can be applied. The PA is now ready for operation.  

3.4

 

TRANSMIT TURN‐ON TIME 

 

Caution: Do not apply transmit data until the PA module is at full power. This will prevent 
loss of data at the beginning of a message. 

 

The  NuPower  12D05A  is  at  full  power  approximately  1  µS  after  the  RF  Enable  line  goes  low  (ground). 
Therefore, transmit data can be applied to the input after 1 µS without loss of data. 

3.5

 

RF OUTPUT POWER VS. SUPPLY VOLTAGE 

The NuPower 12D05A was designed for +28 VDC operation. 
 

Summary of Contents for NuPower 12D05A

Page 1: ...ANUAL NUPOWERTM 12D05A L S BAND POWER AMPLIFIER PART NUMBER NW PA 12D05A NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sales nuwav...

Page 2: ...he chassis Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer sig...

Page 3: ...GaN technology NuPower L Band power efficiency and 10 in3 cubic inch form factor make it ideal for size weight and power constrained broadband RF telemetry and tactical communication systems The NuPo...

Page 4: ...15 Watts min 2300 2400 MHz Output Power 1 dB Compression 33 dBm 2000 MHz 31 dBm 2300 MHz RF Gain 44 dB typ Input VSWR 1 9 typ 2 3 max Output Mismatch No Damage 10 1 Nominal Input Drive Level 0 dBm Max...

Page 5: ...Temperature 40 to 60 o C ambient 40 to 85 o C baseplate Storage Temperature 55 to 85 o C Table 3 NuPower 12D05A Mean Time Between Failure MTBF Conditions Hours Ground Benign GB 292 657 Airborne Inhab...

Page 6: ...NICAL SPECIFICATIONS Figure 2 NuPower 12D05A Mechanical Outline Table 4 NuPower 12D05A Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 9 Pi...

Page 7: ...nana plugs Figure 3 The NuPower PA Kit offers out of the box operation for the user The 28 VDC fan cooled heatsink is shown with the NuPower 12D05A mounted Caution The use of external heat sinking is...

Page 8: ...nsmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB...

Page 9: ...ed into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of the NuPower 12D05A is made up of 9 wires...

Page 10: ...in transmit mode The user can either connect the RF Enable line to pins 1 2 6 8 on the CTRL PWR interface connector or an open drain logic line capable of sinking 500 A to place the unit in transmit m...

Page 11: ...sing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipa...

Page 12: ...Sales Phone 513 360 0800 Email support nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL INFOR...

Reviews: