NuPower
TM
12B01A User Manual
Rev 1.1
3
Parameter
Specification
Supply Voltage
+11 to +32 VDC
Current Consumption
1.5 A @ +28 VDC (typ)
Power Amplifier Enable
GND On
Nominal Input Drive Level
0 dBm
Maximum Input Drive Level
(No damage)
+10 dBm
Impedance
50
Ω
Table 2: NuPower 12B01A Environmental Specifications
Operating Conditions
Specification
Operating Temperature for
Continuous Operation
(>5 minutes)
‐30 to +55
o
C (ambient)
‐30 to +60
o
C (baseplate)
Operating Temperature for 20%
Duty Cycle
‐30 to +60
o
C (ambient)
‐30 to +65
o
C (baseplate)
Storage Temperature
‐40 to +85
o
C
Table 3: NuPower 12B01A Mean Time Between Failure (MTBF)
Conditions
Hours
Ground Benign (GB)
126,690
Airborne Inhabited Cargo (AIC)
14,800
Airborne Inhabited Fighter (AIF)
10,650
Airborne Uninhabited Cargo (AUC)
8,400
Airborne Uninhabited Fighter (AUF)
5,800