5

 

 

2.3

 

HEAT SINKING 

The

 

NuPower

 

12B01A

02

 

is

 

offered

 

as

 

a

 

stand

alone

 

module

 

or

 

with

 

a

 

kit,

 

which

 

also

 

includes

 

a

 

fan

cooled

 

heatsink

 

with

 

an

 

AC

 

/

 

DC

 

adapter,

 

and

 

an

 

interface

 

cable.

  

 

 

Figure 3: The NuPower PA Kit offers “out

of

the

box” operation for the user. The fan

cooled heatsink 

with an AC/DC adapter is shown with an example PA (NuPower 12B01A

02 not shown).  

 

 

 

Caution:

 

The

 

use

 

of

 

external

 

heat

sinking

 

is

 

required

 

especially

 

for

 

those

 

applications

 

requiring

 

high

 

duty

 

cycle

 

operation

 

(e.g.

 

continuous

 

wave)

 

or

 

for

 

extended

 

on

time

 

testing.

 

Operation

 

without

 

a

 

proper

 

heat

 

sink

 

under

 

these

 

conditions

 

will

 

cause

 

permanent

 

damage

 

to

 

the

 

product

 

and

 

will

 

void

 

the

 

product

 

warranty.

 

 

The

 

external

 

heatsink

 

thermal

 

resistance

 

requirements

 

are:

 

 

<0.25

 

˚

C/W

 

for

 

operation

 

up

 

to

 

60

 

˚

C

 

ambient

 

 

<0.7

 

˚

C/W

 

for

 

operation

 

up

 

to

 

40

 

˚

C

 

ambient

 

 

 

 

Summary of Contents for NUPOWER 12B01A-02

Page 1: ...USER MANUAL NUPOWERTM 12B01A 02 L BAND POWER AMPLIFIER PART NUMBER NW PA 12B01A 02 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 www nuwaves com product sales nuwaves com ...

Page 2: ...is Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer significant value for the OEM user or the Systems Integrator User Friendly Reverse Voltage Over Voltage protection and regulator thermal shutdown provide defenses against user interface issues High Reliability N...

Page 3: ...MHz NuPower PAs feature over voltage and reverse voltage protection in addition to a simple control line interface allowing the user to easily place the module into transmit or standby mode of operation A kit is available for purchase which includes a fan cooled heatsink with AC DC power adapter and upgraded interface cable with labeled banana plugs Figure 1 NuPower 12B01A 02 Functional Diagram 2 ...

Page 4: ...ns Operating Conditions Specification Operating Temperature for Continuous Operation 5 minutes 30 to 55 o C ambient 30 to 60 o C baseplate Operating Temperature for 20 Duty Cycle 30 to 60 o C ambient 30 to 65 o C baseplate Storage Temperature 40 to 85 o C Table 3 NuPower 12B01A 02 Mean Time Between Failure MTBF Conditions Hours Ground Benign GB 126 690 Airborne Inhabited Cargo AIC 14 800 Airborne ...

Page 5: ...AL SPECIFICATIONS Figure 2 NuPower 12B01A 02 Mechanical Outline Table 4 NuPower 12B01A 02 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 9 Pin Micro D socket Dimensions L x W x H 3 00 x 2 00 x 0 65 Weight 3 7 oz ...

Page 6: ...AC DC adapter is shown with an example PA NuPower 12B01A 02 not shown Caution The use of external heat sinking is required especially for those applications requiring high duty cycle operation e g continuous wave or for extended on time testing Operation without a proper heat sink under these conditions will cause permanent damage to the product and will void the product warranty The external heat...

Page 7: ...Connecting to a proper antenna through a 50 Ω transmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 Ω power attenuator with minimum 20 dB attenuation Connecting to a load capable of dissipating the RF power from the PA module Loads capable of handling 20 Watts min are recommended 3 3 PO...

Page 8: ...r is the antenna connection This connection should always be loaded into 50 Ω otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of the NuPower 12B01A 02 is made up of 9 wires Table 5 NuPower 12B01A 02 Interface Pin Out Definitions Pin No Pin Name I 0 Description 1 2 V Supply I Primary Power 11 to 32 VDC ...

Page 9: ...fault to standby mode Grounding the pin i e a voltage below 0 2 VDC places the unit in transmit mode The user can either connect the RF Enable line to pins 3 4 on the CTRL PWR interface connector or an open drain logic line capable of sinking 500 µA to place the unit in transmit mode 4 5 TEMP FLAG This signal is a logic level output to indicate an over temperature condition in the NuPower 12B01A 0...

Page 10: ...posing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipal waste Do not export e waste outside of the original destination country for recycling Utilize an e Steward or ISO14001 certified e waste recycler Consider export controls during recycler selection...

Page 11: ... and Sales Email product sales nuwaves com Phone 513 360 0800 NuWaves Home Page https www nuwaves com Product Warranty https nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL INFORMATION Copyright 2006 2020 NuWaves Ltd All rights reserved The information contained in this user manual is copyright protected NuWaves reserves the right to make periodic modifications and product i...

Reviews: