background image

10

IV.  Installing the Simplese Amplifier

The Simplese amplifier component is designed to be 
placed on a shelf or in a component rack. Rack ear 
mounts are supplied with the system. If you are 
using the rack ears and mounting the amplifier with 
other components, you should remove the feet. 
Remove the two screws at the front of each side of 
the lid and use the longer screws included with the 
rack ears to attach the ears to the Simplese 
amplifier.

The audio sources are plugged into the four source 
inputs on the back panel of the Simplese amplifier 
using stereo RCA cables, fig. 4.

V.  IR Outputs

The Simplese System ships with four IR emitters for 
transferring IR data from the keypad receivers 
(located under the volume button) to the IR receiver 
on each piece of source equipment. There are two 
separate IR output sections on the back panel. The 
38Khz outputs are used for most audio sources. The 
exception to this is cable and satellite boxes, which 
operate at a higher IR carrier frequency closer to 
56Khz. A second source one and two 56Khz output is 
available for these devices. It is important that the 
output being used for each source matches the 
source input number. The outputs work individually 
with each source to allow independent source 
control. Simply plug the emitter into the appropriate 
IR output on the back of the Simplese amplifier and 
attach the flasher end over the IR receiver of the 
source equipment, fig. 5.

VI.  Keypad and Zone Setup

Each keypad requires a specific zone setting to 
establish the keypad's location. This setting is made 
on the back of the keypad using an eight-position 
rotary switch. To set the switch, place a small slot-
head screwdriver in the slot in the switch and turn it 
clockwise to the appropriate zone number 1-4, fig. 
6. The remaining switch positions, 5-8, allow for an 
additional keypad in each zone. Position 5 
corresponds to zone 1, 6 to zone 2, 7 to zone 3, and 8 
to zone 4. The additional letters do not apply to 
Simplese. Note that the Allport only has four RJ45 
jacks, so additional keypads require the use of a 
CAT5 splitter.  

Fig. 4

Fig. 5

Fig. 6

SOURCE  INPUT 

L

R

L

R

1

2

3

4

L

R

ZONE 4

FIXED

VAR

LINE OUT 

Source 1
Tuner 1

Audio
Out

SOURCE  INPUT 

L

R

L

R

1

2

3

4

L

R

ZONE 4

FIXED

VAR

LINE OUT 

IR OUT

1

3

2

4

USE FOR SAT

OR CABLE

NORMAL

USE

56KHz

38KHz

1

2

Network

Zone

Address

Connection

Use only with

NuVo Simplese System

WARNING:

AVIS:

Utiliser uniquement avec

NuVo Simplese System

NuVo Technologies LLC Hebron, Kentucky USA
                www.nuvtoechnologies.com

Local Source

Simplese Keypad

Model NV-A4DKP-UK

0

12

F

3

E

4

D

5

C

6

7

B

8

A

9

Summary of Contents for Simplese NV-A4DS-UK

Page 1: ...SimpleseTM NV A4DS UK Installation Manual...

Page 2: ......

Page 3: ...nclosure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that...

Page 4: ...pr s d eau comme par exemple baignoires viers piscine sous sol humides Etc 6 Utiliser exclusivement un chiffon sec pour nettoyer ce produit 7 Ne bloqu r aucune ouverture de ventilation Ne pas placer l...

Page 5: ...e Amplifier Page 10 V IR Outputs Page 10 VI Keypad and Zone Setup Page 10 Zone EQ Control and Source Grouping Page 11 Volume Reset Page 11 All Off Page 11 Master Mode All On Page 12 VII Using the Fixe...

Page 6: ...itional analog amplification The integrated infrared repeater in each keypad means you can control all of your audio sources wirelessly from any zone of your home Enjoying quality audio throughout the...

Page 7: ...Out Source 2 Tuner 2 Audio Out Source 4 DVD Audio Out Source 3 CD Audio Out SOURCE INPUT L R L R 1 2 3 4 L R ZONE 4 FIXED VAR LINE OUT IR OUT 1 3 2 4 SYSTEM LINK RS232 STATUS ON 5V MUTE 0V SPEAKER AND...

Page 8: ...cation to the zone 4 audio outputs 3 IR OUT These outputs are designed to be used with the included IR Infrared emitters to transfer IR function commands from the zone keypads to the appropriate audio...

Page 9: ...te button temporarily silences any audio playing in that keypad s zone 4 Source Selection The source buttons independently select any of the four sources connected to the Simplese amplifier The select...

Page 10: ...rce specific volume control such as a TV or stereo receiver This is not used for NuVo zone volume 6 Numeric Buttons These buttons provide source specific direct numeric access 7 Power Button This powe...

Page 11: ...the wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their correct order and trim them evenly across the top Most crimp tools have a wire trimmer built in It is best to tr...

Page 12: ...eakers per zone Using more than one pair of speakers per zone could cause damage to the amplifier output III Allport Termination and Installation Both the speaker wire and CAT5 cables for each zone te...

Page 13: ...rk individually with each source to allow independent source control Simply plug the emitter into the appropriate IR output on the back of the Simplese amplifier and attach the flasher end over the IR...

Page 14: ...ource 3 Volume Up enables the group function and Volume Down disables the group function and causes the keypad to operate independently of all other groups fig 8 Volume Reset The Simplese System keypa...

Page 15: ...at zone s keypad to flash continuously All other zones will then turn on to the same relative volume level and increase or decrease with the volume adjustment on the master keypad Any of the other zon...

Page 16: ...4 L R ZONE 4 FIXED VAR LINE OUT IR OUT 1 3 2 4 SYSTEM LINK RS232 STATUS ON 5V MUTE 0V SPEAKER AND DATA SIGNALS ALL PORT CONNECTION Simplese CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 3033...

Page 17: ...MUTE 0V SPEAKER AND DATA SIGNALS ALL PORT CONNECTION Simplese CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 3033118 C US RT E E T K N I CM NuVo Technologies Cincinnati Ohio USA D RT E E T K...

Page 18: ...ont of the MI1 The back of the MI1 will accept up to two AC or DC voltages from two different doorbell chimes This connection is done with two conductor wire from the terminals on the doorbell chime t...

Page 19: ...4 FIXED VAR LINE OUT IR OUT 1 3 2 4 SYSTEM LINK RS232 STATUS ON 12V MUTE 0V SPEAKER AND DATA SIGNALS ALL PORT CONNECTION Simplese CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 3033118 C US...

Page 20: ...com L L L L R R R R MODEL NV LSA40 LOCAL SOURCE AMPLIFIER 28VDC TO KEYPAD 1 5A TO AMPLIFIER TO SPEAKER WIRE STRIP 5 16 8MM Designed In USA Made In China NuVo Technologies LLC Cincinnati Ohio USA www...

Page 21: ...keypad has the ability to be set as a source group or remain independent Use the Mute button and the Source 3 button to turn the Source Group feature on and off see Section VI Source Grouping page 11...

Page 22: ...ly control the audio source equipment One or more of the IR emitters are not properly placed over the IR receiver on the audio source equipment or the IR output on the Simplese does not correspond wit...

Page 23: ...mption average 30W Variable output 0 600mV operating conditions Fixed output 600mV Power Consumption no signal Less than10W Impedance 600 Ohms Physical Specifications Source Inputs 1 4 Unit Size Milli...

Page 24: ...Addendum 21...

Page 25: ...22...

Page 26: ...23...

Page 27: ...24...

Page 28: ...25...

Page 29: ...NuVo Technologies 2395 Arbor Tech Drive Hebron Kentucky USA www nuvotechnologies com Ph 859 817 7200 0730...

Reviews: