Nuvo Simplese NV-A4DS-DC Installation Manual Download Page 9

1. Setup:

The setup button is used to place the 
remote control in program/learn mode.

2. Whole-Home Control: 

This section automatically performs the 
basic Essentia keypad functions.

3. Transport Buttons: 

The transport buttons perform basic 
source specific functions, such as play, 
stop, pause, forward and reverse.

4. Video Source Control:

These buttons are typically used by 
video equipment for menu navigation 
and selection.

5. Source Volume:

This is source specific volume control, 
such as a TV or stereo receiver. This is not 
used for NuVo zone volume.

6. Numeric Buttons:

These buttons provide source specific 
direct numeric access.

7. Power Button:

This power button is for source specific 
power on and off. It is not for NuVo zone   
on and off.

8. Channel up and down: 

This button provides source specific 
channel scrolling.

9. Macro Buttons: 

These buttons do not perform a given 
source function. They can be used for 
programming multiple function macro 
commands.

1

2

3

4

5

6

MUTE

VOL-

VOL+

ON/OFF

HOME CONTR

LE-

OL

HO

W

SOURCE

NV-LRC1

M1

M2

M3

M4

M6

M5

M7

M8

1

3

4

2

5

6

7  

8  

9  

LRC1 Learning Remote Control

7

Summary of Contents for Simplese NV-A4DS-DC

Page 1: ......

Page 2: ......

Page 3: ...enclosure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the 0ther A grounding type plug has two blades and a third...

Page 4: ...ar exemple baignoires éviers piscine sous sol humides Etc 6 Utiliser exclusivement un chiffon sec pour nettoyer ce produit 7 Ne bloquér aucune ouverture de ventilation Ne pas placer le produit tout contre un mur ou dans une enceinte fernée cela gênerait le flux d air nécessaire au refroidissement 8 Ne pas placer le produit près de toute source de chaeur telle que radiateurs arrivées d air chaud fo...

Page 5: ... amplification The integrated infrared repeater in each keypad means you can control all of your audio sources wirelessly from any zone of your home Enjoying quality audio throughout the home is simple and affordable with Simplese This installation manual is designed to provide a sequential step by step guide to making full use of the many features and capabilities of the Simplese System Package C...

Page 6: ...V MUTE 0V SPEAKER AND DATA SIGNALS ALL PORT CONNECTION Simplese CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 3033118 C US RT E E T K N I CM NuVo Technologies Cincinnati Ohio USA D RT E E T K N I FOUR SOURCE FOUR ZONE 100 240V 50 60Hz 85W USE FOR SAT OR CABLE NORMAL USE 56KHz 38KHz 1 2 Simplese D Wiring Diagram MUTE CD HD TNR1 TNR2 MUTE CD HD TNR1 TNR2 MUTE CD HD TNR1 TNR2 MUTE CD HD TNR...

Page 7: ...plification to the zone 4 audio outputs 3 IR OUT These outputs are designed to be used with the included IR Infrared emitters to transfer IR function commands from the zone keypads to the appropriate audio source equipment see IR Outputs pg 9 4 MUTE This 3 5mm mono connection is designed to be used in conjunction with the NV MI1 mute interface see Mute Input and the NV MI1 pg 13 5 STATUS This 3 5m...

Page 8: ... under the volume button for wireless control of the audio source equipment 4 Power The power button turns that keypad s zone on and off independently of the other zones Pressing and holding the power button turns all the zones off simultaneously 5 Mute The mute button temporarily silences any audio playing in that keypad s zone 6 Source Selection The source buttons independently select any of the...

Page 9: ...urce specific volume control such as a TV or stereo receiver This is not used for NuVo zone volume 6 Numeric Buttons These buttons provide source specific direct numeric access 7 Power Button This power button is for source specific power on and off It is not for NuVo zone on and off 8 Channel up and down This button provides source specific channel scrolling 9 Macro Buttons These buttons do not p...

Page 10: ...ange the wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their correct order and trim them evenly across the top Most crimp tools have a wire trimmer built in It is best to trim the wires to about in length 4 While holding the wires flat between your thumb and forefinger insert the wires into the Rj45 connector so each is in its own slot Push the wire into the RJ45 so ...

Page 11: ...air of speakers per zone could cause damage to the amplifier output III Allport Termination and Installation Both the speaker wire and Cat 5 cables for each zone terminate into the back side of the Allport The order of Cat 5 plug ins is irrelevant to the operation of the system but it is recommended that you label the individual Cat 5 cables for future reference Follow the zone and polarity labeli...

Page 12: ...ource input number The outputs work individually with each source to allow independent source control Simply plug the emitter into the appropriate IR output on the back of the Simplese amplifier and attach the flasher end over the IR receiver equipment fig 5 VI Keypad and Zone Setup Each keypad requires a specific zone setting to establish the keypad s location This setting is made on the back of ...

Page 13: ...l retain individual volume and on off control This is achieved by pressing Mute and Source 3 Volume Up enables the group function and Volume Down disables the group function and causes the keypad to operate independently of all other groups fig 8 Volume Reset The Simplese System keypads automatically reset the listening volume to a low level when all zones have been turned off and a zone is turned...

Page 14: ...vel and source selection for all other zones To place a keypad in Master Mode function simply press the Mute and Source 4 buttons simultaneously This will cause the volume indicator LED for that zone s keypad to flash continuously All other zones will then turn on to the same relative volume level and increase or decrease with the volume adjustment on the master keypad Any of the other zone keypad...

Page 15: ... 4 L R ZONE 4 FIXED VAR LINE OUT IR OUT 1 3 2 4 SYSTEM LINK RS232 STATUS ON 5V MUTE 0V SPEAKER AND DATA SIGNALS ALL PORT CONNECTION Simplese CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 3033118 C US RT E E T K N I CM NuVo Technologies Cincinnati Ohio USA D RT E E T K N I FOUR SOURCE FOUR ZONE 100 240V 50 60Hz 85W USE FOR SAT OR CABLE NORMAL USE 56KHz 38KHz 1 2 R L SENSITIVITY OdBV 1 0RM...

Page 16: ...SPEAKER AND DATA SIGNALS ALL PORT CONNECTION Simplese CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 3033118 C US RT E E T K N I CM NuVo Technologies Cincinnati Ohio USA D RT E E T K N I FOUR SOURCE FOUR ZONE 100 240V 50 60Hz 85W USE FOR SAT OR CABLE NORMAL USE 56KHz 38KHz 1 2 R L SENSITIVITY OdBV 1 0RMS 12 6 0 LEFT 6 12 RIGHT 0 AUDIO INPUT 2 INPUT OUTPUT CONTROL SPEAKER MODEL NV P2100 HI...

Page 17: ...ront of the MI1 The back of the MI1 will accept up to two AC or DC voltages from two different doorbell chimes This connection is done with two conductor wire from the terminals on the doorbell chime to the Doorbell A or Doorbell B inputs on the back of the MI1 Polarity is not important for this connection Up to two phone lines can be brought into the RJ 11 connection on the back of the MI1 The vo...

Page 18: ...onsumption average 30W Variable output 0 600mV operating conditions Fixed output 600mV Power Consumption no signal Less than10W Impedance 600 Ohms Physical Specifications Source Inputs 1 4 Unit Size Millimeters 44 x 430 x 270 input Impedance 10K Unit Size Inches 1 75 x 17 x 10 625 Input Sensitivity for rated power 300mV RMS Unit Weight Kilograms 2 95 Input Overload 3V RMS Unit Weight Pounds 6 5 Em...

Page 19: ......

Page 20: ...NuVo Technologies 4940 Delhi Pike Cincinnati Ohio 45238 USA www nuvotechnologies com Ph 513 347 2180 SMP 510 05 0650 420NA4DS011 ...

Reviews: