Nuvo Cocerto NV-I8GXS Installation Manual Download Page 34

      Grand Concerto
          Control Pad

LOCAL SOURCE

SWITCH

NV-LSI24

CONNECT TO
   AMPLIFIER

RLY+
RLY-

L-

L+

R-

R+

T

o

 A

m

p

lif

ie

r

To Control Pad

T

o

 S

p

e

a

k

e

rs L-

L+
R-

R+

Model NV-LSI24

Mute Interface Module

The connection from the LSI24 is made through the 
NV-IG8LSA RJ45 port on the back of the Control Pad 
terminated with standard 568A. The connection at 
the LSI24 requires the use of the Brown lead for 
positive and Brown Stripe for negative.

NV-I8GLSA

NuVoNet

32

NV-LSI24 Local Source Interrupt (Fig. 52)

The Local Source Interrupt enables an amplified local audio source to override the Grand Concerto System and play through the 
local zone in-wall speakers. The most common scenario for this is a television that would benefit from higher-quality speakers.

The back of the Grand Concerto Control Pad has two CAT5 inputs. One is labeled NuVoNet and is the CAT5 that runs to the EZ Port at 
the head end. The other is labeled NV-I8GLSA. This is intended to react to the LSI24 accessory. It requires an RJ45 connection at 
the Control Pad end and the Brown and Brown Stripe pair as a voltage trigger.

Note that the Local Source Interrupt is a passive non-amplified device. The signal sent to it must be amplified.

R

OUTPUT POWER

OUTPUT POWER

20W/6OHM X2

20W/6OHM X2

SYS ON

EXT. MUTE

L

L

R

VARIABLE

OUTPUT

FIXED

OUTPUT

SUM1

3033118

C

US

CONFORMS TO

UL STD.6500

CERTIFIED TO

CAN/CSA STD.E60065

NuVo Technologies Cincinnati Ohio USA

FUSE:T5 A

120V       60Hz  500W

MODEL  NV-I8DM

SIX SOURCE EIGHT ZONE

AUDIO DISTRIBUTION SYSTEM

www.nuvotechnologies.com

OUTPUT POWER

OUTPUT POWER

OUTPUT POWER

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

TIP=L

RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

VARIABLE

OUTPUT

VARIABLE

OUTPUT

FIXED

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

   TIP=L
RING=R

1

2

3

4

5

6

1

2

3

4

5

6

2

3

4

1

2

3

RS-232

CONNECT TO

NV-I8X

USE NV-SLC1

CABLE

CONNECT TO

NV-I8X

USE NV-SLC1

CABLE

CONNECT TO

NV-I8EZP1

USE NV-NC1

CABLE

USE CNLY WITH 250V FUSE

4

5

6

SUM2

6

7

8

OUTPUT POWER

20W/6OHM X2

ZONE 6

ZONE 6

ZONE 7&8

SYSTEM

ZONE TRIGGER OUTPUTS

SOURCE LINK

SOURCE INPUTS 

ZONE 1

NETWORK

EMITTER OUTPUTS

DIGITAL LINK

ZONE 3

ZONE 4

ZONE 5

ZONE 2

PROGRAM

1

1

6

4

5

3

2

SOURCE STATUS INPUTS

R

R

R

R

5

1

MENU

OK

drift

SVR

1 of 9

Follow the Day

3:09 PM

3:48

1:28

Edge of Tomorr

Fig. 52

The positive and negative connection on the 
LSI24 act as a relay relay switch between the 
local source input and the audio coming from 
the Grand Concerto System. When zone is 
turned off, is routed to the speakers. When 
the zone is on, the Grand Concerto audio goes 
to the speakers.

Two or four conductor speaker wire from the 
LSI24 to the zone speakers.

Speaker input from Grand Concerto

Amplified signal from the local zone source

The selected zone speaker output of the Grand Concerto 
amplifier is wired directly to the LSI24

Summary of Contents for Cocerto NV-I8GXS

Page 1: ......

Page 2: ...closure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that...

Page 3: ...r s d eau comme par exemple baignoires viers piscine sous sol humides Etc 6 Utiliser exclusivement un chiffon sec pour nettoyer ce produit 7 Ne bloqu r aucune ouverture de ventilation Ne pas placer le...

Page 4: ...nding Grand Concerto to 16 Zones Page 11 IX Using the Grand Concerto Configurator Software Page 11 1 Main Startup Page 11 2 IR Libraries Page 12 3 Defining Sources Page 15 4 Macros Page 16 5 Zones Pag...

Page 5: ...The new OLED organic light emitting diode display allows up to eight lines of text for easily scrolling through music titles and menu selections Capacitive touch controls provide immediate access to t...

Page 6: ...stereo RCA cables 4 Speaker Output Six of the Grand Concerto s eight zones are amplified These outputs accept 16 gage two conductor speaker wire and provide 40 watts per channel of power 5 Source Lin...

Page 7: ...setting parameters 7 Power This button turns the local zone on and off and turns all zones off simultaneously 8 Play Pause This IR programmable button toggles between the play and pause functions of t...

Page 8: ...he first twelve are directly accessible using the RC1 Favorites buttons 6 DISP This button allows access to the Display dim menu available at each Control Pad 7 Function LED This LED Light Emitting Di...

Page 9: ...wires into the correct color scheme as shown in Fig 1 3 Flatten the wires in their correct order and trim them evenly across the top Most crimp tools have a wire trimmer built in It is best to trim th...

Page 10: ...in and the power button on the front panel should be engaged before proceeding with the rest of the installation This activates the internal protective circuitry of the Grand Concerto System IV Insta...

Page 11: ...corresponding audio output on the source equipment and to the desired source input on the back of the Grand Concerto amplifier The numbered input for each source is important in the configuration of t...

Page 12: ...mands to a variety of components NuVo T2G Tuner Direct Numeric Access Fig 7 The NuVo T2G Tuners have the ability for direct IR access to numeric station tuning This can be done through the T2G remote...

Page 13: ...OHM X2 20W 6OHM X2 SYS ON EXT MUTE L R L R L R VARIABLE OUTPUT FIXED OUTPUT SUM1 3033118 C US CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 12...

Page 14: ...see a dialog box asking if you wish to overwrite the existing file If this file is not stored in your computer this box will not appear Fig 10 Fig 12 2 1 IR Libraries Fig 11 The IR Library is a list...

Page 15: ...above Double click on the desired component from the IR Library page This will open the IR Library Editor This window lists the complete set of functions for that type of device To initiate the IR rec...

Page 16: ...iate the On command when a zone is turned on and in turn initiate the Off command when the zone All Off function holding the Power button for three seconds is initiated from any of the Control Pads Fi...

Page 17: ...ource will open the Select Source window This window assigns the appropriate source number input The Display Name is the text that will be read on the Control Pad when that source is selected in any z...

Page 18: ...ssigned Even though the components are assigned you must still set the NuVoNet source inputs on each of the components see Setting Up the T2G Tuners M3 Audio Server and NuVoDock for iPod pg 9 Fig 19 F...

Page 19: ...o string on the right Up to 255 codes can be added to a single macro and the codes will fire in the order in which they are added to the string Once the desired macro string is complete click done and...

Page 20: ...0 entries for zone Control Pads The system can accommodate a total of 20Control Pads by using the slave function in the Edit Zone Properties window A slave Control Pad is homerun to the EZ Port but au...

Page 21: ...e refer to the ability to turn all zones on simultaneously In some zones you may not want this function Bass and Treble Both bass and treble can be adjusted individually on a zone by zone basis The EQ...

Page 22: ...ds This is a useful feature for large rooms where more than one Control Pad is desired If slave Control Pads are used we suggest that you disable the IR pass through on those to prevent cross communic...

Page 23: ...zone mute when the Control Pad power button is tapped When it is held a second menu will appear with the options to turn the zone off or turn all the zones off Tap Zone Off Hold for Group All Off Menu...

Page 24: ...e finished configuration is now ready to be downloaded to the Grand Concerto amplifier While downloading a progress box will show download progress Once complete the configuration is permanently store...

Page 25: ...n Within the main menu of each zone go to Setup Within the Setup options scroll to Advanced Settings and to Zone Number All the used addresses will be grayed out Any available addresses will be access...

Page 26: ...cally reset when an All Off command is issued from a Control Pad Fig 37 Lock Zone Off Adv Zone Control Party Mode Do Not Disturb Lock Zone Sleep 90 Minutes 120 Minutes Sleep Off 15 Minutes 60 Minutes...

Page 27: ...al favorites can be defined for easy access from within the Main Menu or from the twelve numeric favorites from the Grand Concerto remote control Any favorites which include M3 and iPod play lists tun...

Page 28: ...ols this level Maximum Volume is an overall zone volume limit and is set in the same manner as Initial Volume Page Volume controls the level at which a page is amplified in each zone and Party Volume...

Page 29: ...er or specific zone address This is done by scrolling to the desired zone and selecting it All used zone addresses will be grayed out If you have defined zones in the Configurator Software the actual...

Page 30: ...six seconds before the advanced functions are accessible Fig 50 External Mute Page The EXT MUTE input on the back panel of the Grand Concerto has a dual function In normal mode it is designed for the...

Page 31: ...uded in the Learning Station Package This will supply the necessary AC power for IR learning and testing 2 CONNECT TO PC Using one of the supplied RS232 cables connect from the RS232 port on your comp...

Page 32: ...S232 cable to the back of the Interface box into the CONNECT TO PC input At this point it is not necessary to have the Interface box connected to the Grand Concerto amplifier When setting up a new sou...

Page 33: ...Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV I8DM SIX SOURCE EIGHT ZONE AUDIO DISTRIBUTION SYSTEM www nuvotechnologies com OUTPUT POWER OUTPUT POWER OUTPUT POWER 20W 6OHM X2 20W...

Page 34: ...N CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 500W MODEL NV I8DM SIX SOURCE EIGHT ZONE AUDIO DISTRIBUTION SYSTEM www nuvotechnologies com OUTPUT POWER OUTPUT POWER OUTPUT...

Page 35: ...ers When the zone is turned off the internal amplifier of the LSA40 is automatically engaged LSA40 Back LSA40 Front 50 Watt AC power adapter supplied with the LSA40S AC Power Source Any stereo line le...

Page 36: ...X2 20W 6OHM X2 SYS ON EXT MUTE L L R VARIABLE OUTPUT FIXED OUTPUT SUM1 3033118 C US CONFORMS TO UL STD 6500 CERTIFIED TO CAN CSA STD E60065 NuVo Technologies Cincinnati Ohio USA FUSE T5 A 120V 60Hz 5...

Page 37: ...eo to RCA patch cable There are two methods for triggering the P2100 from the Grand Concerto outputs One is to set the POWER MODE switch on the P2100 to AUDIO extreme left position and allow an incomi...

Page 38: ...amplifier Outputs Power Requirements Variable output 0 600mV Power Supply 120VAC 240VAC 50 60Hz Fixed output 600mV Power Consumption all channels 600VA 480W Impedance 600 Ohms driven to full rated pow...

Page 39: ...will display when that cable is connected to the system A damaged MCU must be replaced by NuVo With the Control Pads plugged in the POWER LED on the front of the amplifier will not turn on One or more...

Page 40: ...gh or in the Advanced Zone Setup menu see pg 27 Remote Controls at any Control Pad you have the ability by zone to Disable the IR receiver This will prevent direct sunlight or possibly plasma and fluo...

Page 41: ...www nuvotechnologies com NuVo Technologies LLC Hebron Kentucky USA I8G 0742...