nuVent NXMD1AB Installation Instructions Download Page 1

1.  Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction and standards.  Turn OFF power 

and lock out service panel before installing or wiring this product.  If 

you are unfamiliar with methods of installing electrical wiring, secure 

the services of a qualified electrician.

4.  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to 

prevent backdrafting.  Follow the heating equipment manufacturer's 

guideline and safety standards such as those published by the 

National Fire Protection Association (NFPA) and the American 

Society of Heating, Refrigeration and Air Conditioning Engineers 

(ASHRAE) and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.

7.  NEVER place a switch where it can be reached from a tub or 

shower.

8.  This unit must be grounded.

9.  This unit is UL listed.  Type I.C. inherently protected.

10. This fan is not for use in kitchens.

11. Acceptable for use over a bathtub or shower when installed in a 

GFCI protected circuit.

12. Install fan at least 1.5m (5 feet) above the floor.

CAUTION: FOR GENERAL VENTILATING USE ONLY!

1.  Do not use to exhaust hazardous or explosive materials and 

vapors.

2.  This product is designed for installation in flat ceilings only.  Do 

not mount this product in a wall.

3.  The light fixture assembly must be mounted to the NuVent 

M2000 housing or to a wiring outlet box.

The NuVent Designer Light for use with Bath Fan listed in these 

instructions is designed for use as a fan-light in the bathroom with 

any pre-installed NuVent MR or MS Series fan-light (all of which 

use the M2000 Universal Housing™).  The NuVent Designer Light 

may also be used as a separate light fixture.

Designer Light 

for use with Bath Fan

Models:

NXMD1AB

NXMD1OB

NXMD1WH

INSTALLATION INSTRUCTIONS

1.  The NuVent Designer 

Light has a pre-installed 

quick connector that will not 

be used when the Designer 

Light is used as a separate 

light fixture.  Before 

beginning installation, the 

quick connector must be 

removed.  (

IMPORTANT! 

 

Do not cut these wires if you 

intend to use the designer 

light with a fan.  For that use, 

follow instructions on the 

3.  Using a wire stripper, remove approximately 1/2" of insulation 

from the black and white wires on the Designer Light.

WIRING

:  This product requires 120v AC standard house wiring (with 

ground) from the power source through a standard wall switch.  Turn 

OFF power and lock out service panel before installing or wiring this 

product.  If you are unfamiliar with methods of installing electrical 

wiring, secure the services of a qualified electrician.

4.  Connect the supply wiring to the designer light wiring using UL 

approved connectors: black to black and white to white. Connect 

ground wire from the supply to the Designer Light frame using 

grounding screw removed in Step 2.

2.  Remove the ground wire (green) from the Designer Light frame by 

removing the grounding screw.  Store screw safely until needed in 

Step 4 below.

INSTALLATION INSTRUCTIONS

FOR USE AS A SEPARATE LIGHT FIXTURE 

SAFETY INSTRUCTIONS WARNING: TO REDUCE THE 

RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO 

PERSONS OBSERVE THE FOLLOWING:

• Screwdriver
• Electric drill
• 1/8" drill bit
• Wire cutters
• Wire stripper
• UL approved wire nuts/connectors

TOOLS REQUIRED FOR INSTALLATION

PARTS LIST:

1  Designer Light frame
1  Glass dome
1  Mounting bracket
2  2

1/2

" Philips pan head screws

1/2

" Philips pan head screws

NuVent is the Bath and Kitchen Ventilation product line from Ventamatic, Ltd., 100 Washington St, Mineral Wells, TX 76067   (Phone: 800.433.1626  Fax:  940.325.9311)

Note:  Not all of these parts will 

be used in these installations.  If 

you are missing parts, please 

phone 800.433.1626 and ask for 

Customer Service.

FIGURE 1

5.  Mount Designer Light frame to ceiling box using the two mounting 

screws provided.

reverse side of this page.)  Using a wire cutter, cut each of the three 

wires (white, black, and green) next to the quick connector. (See Figure 1).