NUVE FR 290 User Manual Download Page 20

20 

 

6.1.5.

 

E-MAIL 

 

“E-Mail”  submenu  is  selected  on  the  menu page 
by the value increase (F1) and decrease (F2) keys. 
The  page  shown on the left  appears  when  enter 
key (F4) is pushed. The choice of submenus on e-
mail page is changed by pushing increase (F1) and 
decrease  (F2)  keys.  After  choosing  a  submenu, 
the  adjustments  for  this  submenu  is  made  by 
pushing  enter  key  (F4).  If  you  want  to  exit  this 
page, push the backspace key (F3). 

 

Activation or deactivation of e-mail function can be adjusted from “E-mail” submenu. If you 
want  to  activate  this  function,  choose  “on”  by  pushing  the  enter  key  (F4).  If  you  want  to 
deactivate e-mail function, choose “off” by pushing the enter key (F4).  

 

Ethernet  settings  should  be  adjusted  by  technical  service  staff  for  the  first  usage. 
Otherwise, this function does not work. 

 

“E-Mails” is the page which e-mail addresses will be written on. 

 

 “Login” is the adjustments for the e-mail addresses. 

 

“E-Mails”  is  selected  on  the  e-mail  page  by  the 
value  increase  (F1)  and  decrease  (F2)  keys.  The 
page  on  the  left  appears  when  enter  key  (F4)  is 
pushed. The e-mail addresses can be typed in this 
page and e-mail is sent to these addresses in case 
of any failure.  

 

Each  character  of  e-mail  addresses  is  typed  one  by  one.  The  first  character  is  entered  by 
pushing value increase (F1) and decrease keys (F2) and tab key (F3) is pushed to enter the 
second  character.  The  second  character  is  written  by  pushing  value  increase  (F1)  and 
decrease keys (F2) and tab key (F3) is pushed to enter the next character. After all characters 
are  written  completely in  this  way,  push  the enter  key  (F4)  to  enter the mail  server. After 
mail server is written in the same way, push the enter key (F4) to write next e-mail address. 
After third email address is written, push enter key (F4) to enter other e-mail addresses. 

 

After all e-mail addresses are written as mentioned above, push enter key (F4) and return to 
main page. 

 

Tab key (F3) is used for changeover from one character of address to another. 

 

Summary of Contents for FR 290

Page 1: ...N VE SANAY MALZEMELER MALAT VE T CARET A FR 290 FR 490 FR 590 DEEP FREEZER USER S MANUAL 1984 Z14 K 25 275 Rev No 08 Rev Date 01 2016...

Page 2: ...ate damaged instrument 4 do not operate the instrument with a damaged cable 5 do not move the instrument during operation In case of a problem contact your N ve agent for an authorized service or main...

Page 3: ...nditions use of the product in non standard environmental conditions including but not limited to failure to meet requirements of ambient temperature lubrication humidity or magnetic field influences...

Page 4: ...5 5 POSITIONING 10 5 6 GENERAL PRESENTATION 11 5 6 1 CHAMBER DIMENSIONS 12 5 7 CONTROL PANEL 12 5 8 PRIOR TO OPERATION 14 6 OPERATING PRINCIPLES 14 6 1 PROGRAMMING 14 6 1 1 OPERATING MODE 14 6 1 2 SET...

Page 5: ...4 10 1 AlerText GSM MODULE 24 10 2 N veWARN REMOTE ALARM SYSTEM 25 10 2 1 MOUNTING REMOTE ALARM 25 10 3 CHART RECORDER 26 11 ELECTRICAL CIRCUIT DIAGRAM 27 11 1 FR 290 FR 490 AND FR 590 ELECTRICAL CIRC...

Page 6: ...emperature conditions open door power failure temperature sensor failure and other faults associated with the microprocessor control system The alarm system is fed by an automatically re chargeable ba...

Page 7: ...mpartments internal isolation doors 3 3 4 4 Control System N SmArt Programmable microprocessor system Temperature Indicator Colorful LCD Temperature Recorder Circular Battery operated 7 day chart with...

Page 8: ...mm A 08 159 9 x 9 Divider for up to 13 6 mm tubes Divider height 65 mm A 08 196 Rack with two drawers FR 590 A 08 197 Rack with three drawers FR 590 A 08 198 Rack for 133 x 133 x 75 mm cryoboxes FR 59...

Page 9: ...instructions This symbol refers to important circumstances Labels on the device Earthed Wall Sockets Remote alarm output Normally closed contact output FR 290 490 590 Fuses 2 x 13 A 5 INSTALLATION 5 1...

Page 10: ...hat the supplied mains matches the required power ratings which are written on the name plate of the instrument located at the back of the instrument Always plug in the instrument to correctly grounde...

Page 11: ...11 5 6 GENERAL PRESENTATION Figure 1 Figure 2 CONDENSER FILTER USB PORT 1 USB PORT 2 ETHERNET RS 232 CO2 BACK UP OUTPUT FUSES POWER CORD POWER LED NC CONTACT OUTPUT REMOTE ALARM OUTPUT POWER KEY...

Page 12: ...mpartments different from FR 490 and FR 590 Figure 3 5 7 CONTROL PANEL Figure 4 The functions of F1 F2 F3 and F4 buttons depend on the meaning of the corresponding symbol appearing on the display The...

Page 13: ...return the previous page or exit from the page by pushing the button corresponding to this symbol This symbol denotes the value increase key You can increase the value by pushing the button correspon...

Page 14: ...tely in 3 hours if the chamber is not loaded This period depends on the ambient temperature 6 OPERATING PRINCIPLES 6 1 PROGRAMMING At most 70 of the surface area of the shelves should be loaded in ord...

Page 15: ...2 SETTINGS Settings page appears when settings submenu is selected from the menu page by the value increase F1 and decrease F2 keys The required submenu is chosen by using the value increase and decr...

Page 16: ...shing the value increase F1 and decrease F2 If the option of open is selected activation time of screen saver is adjusted on screen saver time in minutes If you want to exit this page without any chan...

Page 17: ...ng the value increase and decrease keys Push the enter key F4 to access the table Temperature values corresponding to the selected date are shown on three pages Push the value increase F1 and decrease...

Page 18: ...age there are three options Copy History Instant Record and Copy Failure History Copy History As USB stick is connected to the device all data in the internal memory is transferred to USB stick when C...

Page 19: ...crease F1 and decrease F2 keys The page on the left appears when enter key F4 is pushed The phone numbers can be entered in this page and SMS notifications are delivered to these phone numbers in case...

Page 20: ...the e mail addresses E Mails is selected on the e mail page by the value increase F1 and decrease F2 keys The page on the left appears when enter key F4 is pushed The e mail addresses can be typed in...

Page 21: ...is used for changes from one character of address to another 6 1 6 SET TEMPERATURE When the setting key F2 is pushed in the operation mode password page appears This password is the user s password Th...

Page 22: ...enser filter should be cleaned once in a month To access condenser filter pull out the front panel of the compressor compartment See Figure 5 Take out the filter and clean the filter with compressed a...

Page 23: ...st be disposed off according to the regulations for the disposal of electronic components Batteries power packs and similar power source have to be dismounted from electric electronic parts and dispos...

Page 24: ...se contact with an authorized N ve agent to seek technical help 9 2 FUSE REPLACEMENT The fuses shall always be replaced by authorized personnel 10 OPTIONS 10 1 AlerText GSM MODULE In case of error FR...

Page 25: ...ppears in the error history If the GSM module is connected and cannot send messages SMS error code appears in the error history Modem and SMS errors do not appear when SMS submenu on the SMS page is s...

Page 26: ...unit and take it out Put on the battery supplied with device to the hole at the back of the unit by paying attention to and poles Always use leak protected high quality batteries Put the battery unit...

Page 27: ...27 11 ELECTRICAL CIRCUIT DIAGRAM 11 1 FR 290 FR 490 AND FR 590 ELECTRICAL CIRCUIT DIAGRAM...

Reviews: