Nuvap N2Health ProSystem Series User Manual Download Page 3

 

 

 

Nuvap N2Health Manual 

Ver 1.7 

 

1.

 

Introduction 

This user manual provides instructions for the correct installation and use of the Nuvap N2Health device - 

ProSystem series. 

Both the manual and the product described are copyrighted; all rights reserved. Therefore, the user 

manual cannot be reproduced in whole or in part without the formal permission of Nuvap. 

 

2.

 

Device 

Nuvap N2Health is a multisensor device that allows continuous monitoring of 11 environmental parameters: 

-

 

Temperature (resolution 0,1°C, range from -40 to +120 °C) 

-

 

Relative Humidity (resolution 1% Rh, range from 0 to 100 %Rh) 

-

 

TVOC volatile organic compound (resolution 1 ppb up to 2008 ppb, range da 0 to 60000 ppb) 

-

 

Carbon dioxide (resolution 50 ppm up to 5000 ppm, range from 0 to 10000 ppm) 

-

 

Carbon monoxide (resolution 1 ppm, range from 0 to 5000 ppm) 

-

 

Particulate matter, (resolution 1 ug/m3, range from 0 to 1000 ug/m3), granularity: 

o

 

PM 1 

o

 

PM 2,5 

o

 

PM 10 

-

 

Ozone (resolution 0,5 ppm , range from 0 to 5 ppm) 

-

 

Nitrogen dioxide (resolution 0,1 ppm , range from 0 to 30 ppm) 

-

 

Formaldehyde (resolution 0,5 ppm , range from 0 to 10 ppm) 

In addition to detecting the parameters listed above, the device performs a calculation based on Nuvap 
algorithms to build the synthetic Nuvap Index indicator. The Nuvap Index allows to identify the level of 
healthiness of the environment in which the device is placed, with a value between one and ten (one indicates 
the "Poor" air quality level and ten indicates an "Excellent” quality). 

The device continuously measures the detected parameters. Approximately every 15 minutes it transmits the 
aggregate data (5 values per each parameter) to the Nuvap cloud platform: 

-

 

Minimum value of the last 15 minutes 

-

 

Maximum value of the last 15 minutes 

-

 

Average value (depending of the parameter the average is weighted based over previous sampled 
values)  

-

 

Value at the beginning of the sampling period 

-

 

Value at the end of the sampling period 

The data, in addition to being transmitted to the cloud, can be saved in the internal memory of the device, 
which allows to keep up to 30 days of historical data. In case of lack of connectivity, the data are locally 
stored, until they are transmitted to the cloud (when the connectivity is restored). 

The device is equipped with two connectivity technologies for data transmission: 

-

 

WiFi 2.4Ghz 802.11 b/g authentication WPA PSK 

-

 

LTE Cat M1/Cat NB1/EGPRS 850/900/1800/1900MHz (micro SIM - pre-installed) 

The BTLE connectivity protocol is used only for the configuration and commissioning phase of the device. 

Summary of Contents for N2Health ProSystem Series

Page 1: ...Nuvap N2Health Manual Ver 1 7 1 Nuvap N2Health ProSystem Series User Manual...

Page 2: ...on 3 2 Device 3 3 Nuvap platform and smartphone application 4 4 Device installation 5 5 Device configuration 5 6 Device Reset 6 7 Sound and light emissions 6 8 Maintenance 7 9 Disposal 7 10 Certificat...

Page 3: ...alculation based on Nuvap algorithms to build the synthetic Nuvap Index indicator The Nuvap Index allows to identify the level of healthiness of the environment in which the device is placed with a va...

Page 4: ...uvap services and devices by the ProSystem solution s users The platform provides the following main services Device management User management Collection and elaboration of the sensors data Value add...

Page 5: ...hentication password The device supports the types of WiFi networks indicated in the The Device section of this manual Configuration with mobile connectivity the SIM is supplied pre installed by Nuvap...

Page 6: ...ough the following procedure If already powered turn the device off and on again using the power button Wait 2 minutes for the device to activate the features With the palm of your hand press the touc...

Page 7: ...to your sales representative for more information about this service For each device the calibration certificate issued by the manufacturer may be requested by sending an email to support nuvap com i...

Page 8: ...EU It is stated that the following standards and or specifications have been applied IEC 61010 1 2010 e EN 61010 1 2010 EN 61326 1 2013 ETSI EN 301 489 1 V2 1 1 ETSI EN 301 489 17 V3 1 1 ETSI EN 300 3...

Page 9: ...k via the supplied AC DC power supply It must be used in environments with temperatures between 5 C 25 f and 40 c 105 f It has been designed to be used indoors at work or in residential areas it is no...

Reviews: