The condensate tank must be drained daily or every 6 working hours.
You may run a hose from the condensate tank into a larger receiver and leave
the ball valve in the open position.
•
Manually open auto drain valves each day
to check for condensate and that the auto
drains are functioning properly.
14.0 Power Requirements
Never use extension cords to provide power to your compressor system. The system must be
properly wired according to national and local electrical codes by a qualified electrician. Improper
wiring may lead to fires, which can cause serious personal injury or death.
Electrical wiring and connections should be made by a qualified electrician in accordance with all national and
local electrical codes. Check all system specifications provided in this manual when working on the
compressor system the main breaker at the power source must be “locked out” in the off position.
14.1 Amperage Load for System
14.2 Rotation Check
Always turn on (bump) starter and run motor very briefly to check for proper direction of
rotation. A sticker indicates proper rotation direction.
Operation in reverse direction for extended periods of time will cause a Reciprocating Compressor to
run hot and perform poorly and may cause permanent damage.
15.0 Storage
Should the compressor not be used, it must be stored in a dry sheltered area at an ambient temperature of
b32°F and +104°F (0°C and +40°C). Store the compressor away from sources of heat, flames or
explosive.
208-230 V / E3 / 60 Hz
380-415 V / E3 / 50 Hz
440-480 V / E3 / 60 Hz
38 A 15 hp (11 kW)
×
2
21 A 15 hp (11 kW)
×
2
17 A 15 hp (11 kW)
×
2
Condensate
Tank
Manual Bleed Valve for
Condensate Tank
Auto Drain Valves with
Manual Bleed Valves
Summary of Contents for MCH60
Page 1: ...Operation Manual MCH60...
Page 2: ...MCH60 Nuvair Page 1 www Nuvair com Notes...
Page 3: ...MCH60 Nuvair Page 2 www Nuvair com Notes...
Page 37: ...MCH60 Nuvair Page 36 www Nuvair com 19 0 Service Log Date Technician Name Service Performed...
Page 41: ...MCH60 Nuvair Page 40 www Nuvair com Notes...