14.0 Power Requirements
Never use extension cords to provide power to your compressor system. The system must be
properly wired according to national and local electrical codes by a qualified electrician. Improper
wiring may lead to fires, which can cause serious personal injury or death.
Electrical wiring and connections should be made by a qualified electrician in accordance with all national and
local electrical codes. Check all system specifications provided in this manual when working on the
compressor system
the main breaker at the power source must be “locked out” in the off position.
14.1 Amperage System Load
Voltage
Phases
Hertz
Amperage
Horsepower
Kilowatts
208-230
3
60
48
20
15
380-415
3
50
29
20
15
440-480
3
60
25
20
15
14.2 Rotation Check
Always turn on (bump) starter and run motor very briefly to check for proper
direction of rotation. A sticker (Figure 33) indicates proper rotation direction. A
directional arrow is also stamped into the fan cover.
Operation in reverse direction for extended periods of time will cause a reciprocating compressor to
run hot and perform poorly and may cause permanent damage.