MCH36 Silent Touch
Nuvair
Page 25
www.Nuvair.com
•
The extension, supplied as an optional, must be
connected to the intake connector (
“a,” Figure
•
Connect extension pipe to fitting.
•
Pass the pipe through the hole on the side panel
(
“b,” Figure 15).
•
Fit the supplementary intake filter on the
extremity of the extension pipe.
•
Position the end of the extension with the air
intake filter in a properly ventilated area
sheltered from weather and exhaust fumes.
•
Point the air intake against the wind.
•
Check that there are no kinks or breaks along the pipe. If it is damaged replace it.
8.3
Electrical Connection
•
Please read all information supplied before connecting electricity to the compressor system.
•
You should hire a licensed electrician to install any electric compressors purchased from Nuvair.
•
The compressor is delivered with raw leads ready to be installed into a junction box.
•
In the event a plug is needed, Nuvair recommends that the licensed electrician doing the install
determines the plug necessary.
•
An efficient compressor grounding system is an essential compressor safety requisite.
•
Make sure your electrician follows approved and compliant standards for your location.
9.0
Checks for the Start of Each Working Day
Inspect the exterior of the compressor (couplings, pipes, pneumatic components, etc.) and check for any oil
leaks. Replace parts where necessary or contact
Nuvair
.
9.1
Lubricating Oil Level Check
Check that the level of lubricating oil is within acceptable limits (i.e.,
between minimum and maximum on the oil level viewer). Note that
an excessive quantity of oil can leave deposits on the valves while
too low a level prevents proper lubrication and could cause
compressor seizure.
If the oil level is not within the minimum and maximum limits of the
oil level viewer, top up or drain as described in section 13.6,
“Checking and Changing the Lubricating Oil & Filter.”
9.2
Check Refill Hoses
Inspect the refill hoses and make sure there are no cuts, holes, abrasions, leaks etc. If necessary, replace with
new hoses.
9.3
Check the Safety Valves
Figure 15. Air extension connection diagram.