4. Registration
Scanner Quick Reference Card
A.
Download one of the NutriOpt or AgroCares mobile apps from the Google Play Store. In order to use
the app, you need a valid license key. You can purchase your license from the AgroCares webshop
(webshop.agrocares.com).
B.
Register your account in the app and login with the same credentials (email and password) that were
used for the webshop, or register directly in app. After logging in, you can enter the license key.
B.
The device name of your Scanner is on the
back side of the handle. The device name
should follow this scheme: ‘SC_xxxxX’.
C.
Navigate to Account and select your Scanner from ‘Device Settings’. After the app and the Scanner are connected, you
can proceed with scanning. Follow the instructions that are given in the app.
The ‘reset’ icon is located on the side of the Scanner. Reset the Scanner by touching the ‘reset’ icon with the magnet part
of the charger cable. You will hear a soft click. Press the ‘Scan’ button for 3 seconds to start it up again.
6. Resetting your Scanner
Lo
5. Starting-up and connecting the Scanner
A.
Turning the Scanner ON. Press the SCAN
button (1A) for 3 seconds. The Scanner will
initiate its start-up sequence indicated by the
blinking green battery icon. The Scanner is
ready to be connected via Bluetooth when the
battery icon (1C) turns continuously green and
the Bluetooth indicator (1B) starts blinking.
IR
IR
De
vic
e n
ame :
SC_1
34C
ser
ial n
umber
:
R5
22GH2
34
in
pu
t:
DC = 5
V/1
.6A
design
an
d pr
odu
ction
loc
ation
:
The Netherlands
De
vic
e name :
SC_134C
serial number :
R522GH234
input:
DC = 5V/1.6A
design and pr
oduction l
oc
ation:
The Netherlands
RESET
Cleaning your Scanner:
Proper care of the sensor head is needed to ensure a good performance of the device. Therefore, the bottom needs to be
kept clean at all times by using the cloth and the brush.
Cleaning your calibration cap:
The yellow side of the calibration cap cannot, in any way, handle water. Additionally, the yellow part is made out of fibre
material which can’t be brushed. Scan the yellow side only with a clean scanner and wipe it gently with a soft cloth if it is
a bit dirty.
The white part of the calibration cap needs to be clean and dry. The white side can be cleaned with a moist towel with a
drop of an abrasive cleaning product. The material of the white side absorbs water, therefore drying takes several hours.
The cap can be dried on the heater.
7. Cleaning
More information
Check for additional information, instructions and manuals at your portal via www.agrocares.com
and check www.nutriopt.com/onsiteadviser for more information about your NutriOpt license.