background image

ZN110HL  Installation Guide

Page 2

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and 

Air Conditioning Engineers (ASHRAE), and the local code 

authorities.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Do not use this fan with any solid-state speed control device.
8.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

9.  This unit must be grounded.

Typical Installation

CAUTION

1

.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  This product is designed for installation in flat ceilings. Sensor 

will not function reliably if product is not installed in flat ceiling. 

DO NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced  

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further 

information and requirements.

45°

45°

•  Installation is the same for:

•  Fits in 2" x 8" ceiling construction.
•  Infinitely adjust the fan position 

between joists from 14" to 24"  
on center.

*Purchase

separately.

INSULATION*

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

ROUND

DUCT*

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

NOT FOR USE IN A COOKING AREA

 Do not install above or inside this area

Floor

Cooking
Equipment

Joists    I-Joists          Trusses

Summary of Contents for ZN110HL sheet

Page 1: ...with homeowner Register your product online at www nutone com register Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Con...

Page 2: ...n cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Do not use this fan with any solid state spe...

Page 3: ...er with a Phillips bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 6 round metal ducting recommended for best performance Use of other ductin...

Page 4: ...ucting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing I...

Page 5: ...ate Knockout Plate mounts to outside of Housing and may be oriented as desired Connect wires Fan Light LIGHT WHT MANUAL ON GRD WHT BLK GRD WHT BLK RED 120 VAC LINE IN MULTI FUNCTION WALL SWITCHES SENS...

Page 6: ...inish Ceiling 7 Install Grille 8 Install Bulbs See Page 12 for Operations Cleaning and Maintenance and Troubleshooting Mask protects unit during construction Remove before installing Grille Night Ligh...

Page 7: ...aged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Remove CFL Bulbs from protective packaging Punch out Mask from...

Page 8: ...1 1 2 3 3 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Re...

Page 9: ...tep 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting and Duct Connector 8 Secure Moun...

Page 10: ...operate the light Attach cable clamps to Knockout Plate Knockout Plate mounts to inside of Housing and may be oriented as desired LIGHT WHT BLU NIGHT LIGHT RED MASTER NIGHT LIGHT GRD WHT BLK GRD 120...

Page 11: ...e Blower Assembly 13 Install Grille 14 Install Bulbs If ceiling repairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before in...

Page 12: ...justable Airflow Rate Using a small flat blade screwdriver carefully rotate the CFM adjustment until the arrow points to the desired airflow rate To Set the User Adjustable Time Delay Using a small fl...

Page 13: ...e d damage caused by faulty installation or installation or use contrary to recommendations or instructions e any Fan that has been moved from its original point of installation f damage caused by env...

Page 14: ...ZN110HL Installation Guide Page 14 99044861A...

Page 15: ...la casa Registre su producto en l nea en www nutone com register F cil instalaci n en construcciones nuevas y en aplicaciones de conversi n ndice Advertencias y precauciones 16 Instalaci n t pica 16...

Page 16: ...e la pared o del cielo raso tenga cuidado de no da ar el cableado el ctrico ni otros servicios ocultos 6 Los ventiladores con conductos siempre se deben conectar hacia el exterior 7 No use este ventil...

Page 17: ...stornillador de cabeza plana Alicates Desforrador de cables Cortador de cables Materiales necesarios Se recomienda utilizar conductos met licos redondos de 6 pulg 15 2 cm para obtener un desempe o pti...

Page 18: ...l a ambos lados del marco de montaje para fijar la cubierta en su lugar No doble la cubierta Tornillos de la bolsa de piezas Las bridas superior e inferior se instalan por fuera de la cubierta Introdu...

Page 19: ...uede orientarse en la direcci n que se desee Conecte los cables Ventilador L mpara L MPARA BLANCO ENCENDIDO MANUAL TIERRA BLANCO NEGRO TIERRA BLANCO NEGRO ROJO INTERRUPTORES DE PARED MULTIFUNCIONALES...

Page 20: ...la 8 Instale las bombillas Consulte la p gina 26 para obtener informaci n sobre el funcionamiento limpieza mantenimiento y resoluci n de problemas La cubierta protege la unidad durante la construcci n...

Page 21: ...Sierra para panel de yeso Martillo de u as o pata de cabra Navaja utilitaria Materiales necesarios Cinta para sellar las conexiones de los conductos Los conductos r gidos existentes requerir n la adi...

Page 22: ...el conjunto del ventilador 6 Retire el panel de cableado 7 Inserte el marco de montaje Ambos lados Ponga a un lado el conjunto del ventilador Ponga a un lado el panel de cableado Ponga a un lado el t...

Page 23: ...que lo inserta en el marco de montaje Tire de los conductos existentes hacia el interior de la cubierta 10 Acople el conector de conductos y los conductos 8 Sujete el marco de montaje 9 Encaje la cub...

Page 24: ...de agujero ciego La placa de agujero ciego se monta en el interior de la cubierta y puede orientarse en la direcci n que se desee L MPARA BLANCO AZUL L MPARA DE NOCHE ROJO L MPARA DE NOCHE TIERRA BLA...

Page 25: ...ombillas Si es necesario realizar reparaciones en el cielo raso coloque el protector en la cubierta despu s de haber fijado el conjunto del ventilador Consulte el paso 6 sobre la instalaci n en una co...

Page 26: ...o est situado en la esquina de la cubierta del ventilador detr s de la rejilla C mo ajustar el ndice de flujo de aire ajustable por el usuario Utilizando un destornillador peque o de cabeza plana gire...

Page 27: ...n o uso contrario a las recomendaciones o instrucciones e todo Ventilador que se haya trasladado del punto original de instalaci n f da o provocado por elementos naturales o ambientales g da o durant...

Page 28: ...Gu a de instalaci n del ventilador ZN110HL P gina 28 99044861A...