NuTone VX1040CC Operating Instructions Manual Download Page 4

page 4

Trouble

1.

Loss or
decrease of
vacuum occurs.

2

. Power unit does

not start, or
shuts off during
normal operation
with no LED
showing red or
illuminated.

Possible Cause

1a.

Debris pail is completely full.

1b.

Obstruction in the hose. A blockage in the hose 
can be determined by inserting the hose into any 
wall inlet and, while power unit is running, check 
each additional inlet for normal suction by holding
the palm of your hand over the open inlet. If normal 
suction is felt at all other inlets, insert the hose 
into a second inlet. If the blockage still exists it is 
located in the hose. However, if the blockage 
does not occur when the hose is changed, the 
blockage is probably located in the tubing system
leading to the original inlet.

1c.

Obstruction in the tubing system inside 
the walls.

1d.

Wall inlet cover not properly sealed.

1e.

Exhaust tubing or vent clogged.

2a.

Defective inlet. Check other wall inlets.

2b.

Thermoprotector has been activated OR there is 
a tripped circuit breaker on the unit.

2c.

Blown fuse or tripped circuit breaker on house 
electrical panel.

2d.

Defective hose.

2e.

Microprocessor lockup. 

NOTE

:

This apply only to NuTone VX550CC 
& VX1040CC.

2f.

Low line voltage.

Possible Remedy

1a.

Empty debris pail as described on page 3.

1b.

Insert handle end of hose into utility valve at 
power unit. Turn unit on. This will reverse normal 
air flow through the hose and dislodge any clogs.

1c.

Insert hose end into any inlet with power unit 
running, place the palm of your hand over the  
opposite end of the hose. When you can feel the 
suction increase, hold your hand over the hose 
end for a few seconds and then quickly remove 
your hand. This procedure repeated several 
times should clear the obstruction. If the blockage
is not cleared, contact your nearest Service Center.

1d

.Check all wall inlet covers to be sure they are 

closed and sealed tightly.

1e.

Inspect and remove any blockages.

2a

. Replace defective wall inlet.

2b.

Turn unit off for 20 minutes then plug unit back in.
If unit does not start, look for the tripped circuit 
breaker behind the unit, a white button has 
popped up, push it back to reset it. If circuit 
breaker trips again, unplug your unit and contact 
your local Service Center.

2c

. Replace fuse or reset circuit breaker on house 

electrical panel.

2d.

Replace hose as required.

2e.

1) Push 

Reset

button while unit is engaged OR

2) Unplug unit completely for 60 seconds.

2f.

Contact your local Service Center.

TROUBLESHOOTING GUIDE

Read before calling Service Center.

Summary of Contents for VX1040CC

Page 1: ...042320 rev F For Power Unit NuTone models VX475CC VX550CC VX1040CC AB0002 HOMEOWNER S OPERATING INSTRUCTIONS CENTRAL VACUUM POWER UNIT Broan NuTone Canada Mississauga Ontario www nutone ca 877 896 111...

Page 2: ...cted by a specialized technician once a year OPERATION The power unit is located away from the everyday living areas of your home usually in the garage basement or utility room Through a network of st...

Page 3: ...articles from escaping to the outside of the power unit The filter cleans itself by moving up when the power unit starts and dropping down when the unit is turned off The filter can be removed by mean...

Page 4: ...NuTone VX550CC VX1040CC 2f Low line voltage Possible Remedy 1a Empty debris pail as described on page 3 1b Insert handle end of hose into utility valve at power unit Turn unit on This will reverse nor...

Page 5: ...3a A complete check of all wall inlets and power unit low voltage control lead connections Contact your authorized Service Center 4a Empty debris pail as described in page 3 5a Contact your local Serv...

Page 6: ...15R receptacle or a dedicated 20 amp branch circuit with a NEMA 5 20R for NuTone models VX475CC VX550CC For NuTone model VX1040CC a nominal 240VAC dedicated 20 amp branch circuit with NEMA 6 20R recep...

Page 7: ...crews X 10941195 TS2 Motherboard Daughterboard S A incl screws X 5 10941235 VS motor with motor harness fuse with fuse harness circuit breaker X 10941236 TS1 motor with motor harness fuse with fuse ha...

Page 8: ...ada or an authorized representative faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the period as specified for...

Reviews: