INSTALLATION
OPTION #1 - UNDER CABINET ACCESS TO PIPING FROM BELOW
Refer to Figure 2
1. Select a location under cabinet for VacPan™ (6) so that new fittings can be connected to existing pipe. Drill small
reference hole under location of VacPan™ to determine position in basement or crawl space.
2. Using a hole saw, cut access hole (3) in floor under cabinet. Position access hole (3) so that final fittings (7) can be
installed by reaching through access hole (3).
3. Cut 6
3
/
4
" long slot along kick (4) of cabinet.
4. Make terminal connections (5).
5. Slide VacPan™ (6) into slot and secure using #6 painted wood screws provided.
6. Reach through access hole (3) and make final fitting connections (7).
IF ACCESS CANNOT BE MADE FROM BELOW
1. Rough-in pipe (8) through floor,
provide 1/2" play in pipe.
2. Provide slack in low voltage lines for future connection.
3. Once cabinets are installed, cut access hole (13) and cover with
cover plate
(14). Reach through and make final
connections as per previous installation.
FIGURE 2
COVER ACCESS PLATE
(IF REQUIRED ACCESS CANNOT
BE MADE FROM BELOW)
KICKSPACE
FINAL FITTING
CONNECTIONS
VACPAN™
SUBFLOOR
JOIST SPACE
ALLOW
1
/
2
" FLEX IN PIPE
TERMINAL
CONNECTIONS
HATCHED AREA
REPRESENTS “ROUGH-IN”
PIPING
ACCESS HOLE IN SUBFLOORING
UNDER CABINET
TO CENTRAL VAC
IF CEILING IS INSTALLED - PROVIDE COVER PLATE IN
BOTTOM OF CABINET TO MAKE FITTING CONNECTIONS.
(IF CEILING IS NOT INSTALLED, FINAL FITTING
CONNECTIONS CAN BE MADE THROUGH ACCESS HOLE IN
SUBFLOOR.
CABINET
7
4
6
5
3
8
13