background image

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

R o u g h - I n
Speaker Frame

MODEL: IR-3

For use with NuTone Speakers

L O C AT I O N

1. Locate speaker frame at a convenient operating height:

approximately 4

1

2

' above the floor.

2. For mounting purposes, locate speaker next to a wall

s t u d s .

3. To avoid feedback, do not locate any speaker and/or

Master Station housing back to back or in a common 
all between rooms.

M O U N T I N G

To accommodate the speaker panel, allow a minimum

clearance – on all sides of rough-in frame – of 2". 
Wall depth required: 1

3

4

".

IMPORTANT: The Rough-In Housing must be mounted

in vertical position.

NEW CONSTRUCTION

1. 

Refer to Figure 1.

In a plaster installation, place the

housing's 

3

4

" plaster flange TOWARDS the finished side 

of the wall.

2. 

Refer to Figure 2.

In a drywall installation, place the

housing's plaster flange AWAY from the finished side 
of the wall.

EXISTING CONSTRUCTION

1. Be certain area behind the wall where frame will be located

is free of obstructions.

2. Use the frame as a template for marking the required

cutout. Place the frame's plaster flange against the wall 
at the desired location. Make a line around the inside 
edge of the frame.

3. Make the cutout. Carefully cut along the inside 

of the marked line.

4. Insert frame into cutout and mark location of four 

mounting holes.

5. Remove frame and drill four pilot holes.
6. Reinsert frame into cutout and secure with screws

p r o v i d e d .

W I R I N G

1. The wiring and rough-in should be installed when the

intercom system is roughed-in. Leave sufficient wire 
(at least 1 foot) for connection to speaker.

2. Run wire from speaker location to master unit location. 

Use wire specified for the system being installed; refer 
to installation instructions provided with the Master Station.

IMPORTANT: Use only NuTone specified wire. See

Master Station installation instructions for complete
system installation.

FIGURE 1

FIGURE 2

PLASTER
FLANGE

IR-3
ROUGH-IN
FRAME

PLASTER
FLANGE

IR-3
ROUGH-IN
FRAME