background image

4

WIRING DIAGRAMS

1101653A

Tape mask into housing. 

Mask protects unit during 

construction. Remove 

before attaching grille.
Install ceiling material. Cut 

out around housing.

Install housing mask.

1

7

Attach grille.

1

8

If grille spring becomes 

dislodged from grille - snap it 

back into place as shown.

Connect wiring.

1

6

Screw from 

Parts Bag

Attach cable clamp to 

Knockout Plate. Knockout 

Plate mounts to outside of 

Housing and may be oriented 

as desired.

Connect wires

3

4

1

2

Connect power cable to wiring 

plate (from parts bag) using UL 

approved connector. Connect 

house wiring to fan wiring. Refer 

to wiring diagrams for connection 

details. Use screw (from parts 

bag) to secure wiring plate to fan 

housing. Re-install wiring panel 

and secure with screw from parts bag.

3

4

1

2

1

3

2

1

3

2

ON / OFF SWITCH

(PURCHASE SEPARATELY)

ON / OFF

SWITCH

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

BLK

WHT

UNIT

ORG

BLK

WHT

GRD

WHT

BLK

WHT

BRN

HUMIDITY
CONTROL

FAN

RED

RED

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

WHT

UNIT

BLK

WHT

GRD

WHT

BLK

WHT

HUMIDITY
CONTROL

FAN

RED

BLK

ORG

BRN

2-FUNCTION CONTROL

(PURCHASE SEPARATELY)

COM

(1)

HUMIDITY
CONTROL

(AUTO/OFF)

(2)

FAN

(ON/OFF)

WIRING OPTION #1

•  When switch is ON, fan will operate automatically, 

based on room humidity conditions.

•  Turn fan ON immediately for the set timer period (to 

control odors), by cycling switch.

WIRING OPTION #2

•  When first switch (1) is ON, fan will operate automatically based on 

room humidity conditions.

•  Turn fan ON 

immediately 

(to control 

odors) by 

using sec-

ond switch 

(2).

Plug in sensor

Summary of Contents for QT DC Series

Page 1: ... sensor is mounted in the control housing The sensor will operate most reliably when cleaned occasionally as follows 1 Disconnect power at service entrance 2 Remove the grille Use a dry dustcloth clean toothbrush or lightly vacuumtocleansensorandgrille DONOTUSEABRASIVECLOTH STEEL WOOL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor READ AND SAVE THESE ...

Page 2: ...not install above or inside this area 45o 45o NOT FOR USE IN A COOKING AREA Housing mounted to I joists Use I joist spacer block provided Housing mounted anywhere between I joists using hanger bars Housing mounted to joists Housing mounted anywhere between joists using hanger bars Housing mounted to truss Housing mounted anywhere between trusses using hanger bars TYPICAL INSTALLATIONS ROOF CAP wit...

Page 3: ... secure blower to housing Screws from parts bag 1 3a Mount housing to joist SPACER use for mounting to I Joist I JOIST Hold housing in place so that bottom edge of housing will be flush with finished surface of ceiling For 1 2 thick ceiling material position bottom of each mounting flange flush with the bottom of joist The housing mounts with four 4 screws or nails Screw or nail housing to joist t...

Page 4: ...arts bag to secure wiring plate to fan housing Re install wiring panel and secure with screw from parts bag 3 4 1 2 1 3 2 1 3 2 ON OFF SWITCH PURCHASE SEPARATELY ON OFF SWITCH 120 VAC LINE IN SWITCH BOX WHT GRD BLK WHT UNIT ORG BLK WHT GRD WHT BLK WHT BRN HUMIDITY CONTROL FAN RED RED 120 VAC LINE IN SWITCH BOX WHT GRD WHT UNIT BLK WHT GRD WHT BLK WHT HUMIDITY CONTROL FAN RED BLK ORG BRN 2 FUNCTION...

Reviews: