NuTone Premier NP60000 Series Installation Instructions Manual Download Page 4

HL0075

- 4 -

RMP SERIES BACKSPLASH

(Stainless steel wall covering

with warming shelves. Optional)

Model 415

(7” round adjustable elbow)

Model 427 

(4 

1

/

2

” x 18 

1

/

2

” 

to 10” round, 

6” high - lateral

Model 423 

(4 

1

/

2

” x 18 

1

/

2

” to

10” round - vertical

Model 424 

(4 

1

/

2

” x 18 

1

/

2

” to

10” round - horiz.

front/rear

Model 454 

(4 

1

/

2

” x 18 

1

/

2

” 

to 10” round -

horiz. /right

Model 453 

(4 

1

/

2

” x 18 

1

/

2

” 

to 10” round -

horiz. /left

NP60000

SERIES HOOD

(Canopy with

blower controls

& lighting.

Required for all

installations.)

OPTIONAL 
SOFFIT CHIMNEY
RMN SERIES

NP60000 SERIES

RANGE HOOD SYSTEM -

INTERIOR BLOWERS

Model 437

(High capacity roof cap)

Model 441

(10’’ round wall cap)

Model 634 or 644

(roof cap)

Model 647

(7” round wall cap)

Model 407

(7” round duct—2 ft. sections)

Model 410 

(10” round duct—2 ft. sections)

MODEL RM325H 
BLOWER/ROUGH-IN KIT 

(600 cfm interior blower &
rough-in plate)

MODEL RM326H 
BLOWER/ROUGH-IN KIT 

(1200 cfm interior blower
& rough-in plate)

Model 418

(10” round adjustable elbow)

OPTIONAL 
BAFFLE FILTERS
RBF SERIES

Summary of Contents for Premier NP60000 Series

Page 1: ...LY INSTALLER LEAVE THIS MANUAL TO HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 11 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 www nutone com V7450 rev A HB0026 INSTALLATIO...

Page 2: ...lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIATELY EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may...

Page 3: ...subject to misuse negligence accident improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The duration of any impl...

Page 4: ...P60000 SERIES HOOD Canopy with blower controls lighting Required for all installations OPTIONAL SOFFIT CHIMNEY RMN SERIES NP60000 SERIES RANGE HOOD SYSTEM INTERIOR BLOWERS Model 437 High capacity roof...

Page 5: ...Model 335 1200 cfm or 336 1500 cfm exterior blower Model 441 10 Round wall cap Model 437 High capacity roof cap Model 441 10 round wall cap Model 421 10 round vert in line damper Recommended for use w...

Page 6: ...roper sized ductwork elbows and roof or wall cap for the type of blower you are installing Use 2 duct tape to seal duct joints 7 178 mm ROUND DUCT ROOF CAP 7 178 mm ROUND ELBOW 24 TO 30 609 to 762 mm...

Page 7: ...lbows dampers wall and roof caps Refer to pages 4 and 5 for a complete list of venting options and model numbers Using a Phillips 2 or a Robertson 2 screwdriver unscrew the hood from the bottom of cra...

Page 8: ...s provided CAUTION Due to the weight of this hood ensure that the wood strip is attached to all of the available studs 2 studs minimum for a 30 hood more as wood width increases not into the drywall a...

Page 9: ...cover from rough in plate and set aside Connect BLACK to BLACK WHITE to WHITE and GREEN or bare wire under GREEN ground screw Reinstall wiring cover HD0063 1 1 1 1 2 3 4 1 Locknuts 3 Rough in plate on...

Page 10: ...ng finger sized cup pull on the upper end of filter and slide it under the front inner retaining piece Replacement filters are available from your dealer See label inside hood for size and part number...

Page 11: ...with warm water and mild detergent only When discoloration occcurs use a good enamel polish such as automotive polish DO NOT use rough abrasive cleaner or porcelain cleaner HD0069 16 OPERATION Always...

Page 12: ...NUT 8 32 2 2 2 2 2 2 2 2 13 V02512 SCREW 8 32 X 1 2 QUADREX 2 2 2 2 2 2 2 2 14 V01869 MACHINE SCREW 8 32 X 1 4 2 2 2 2 2 2 2 2 15 V01582 LOCK NUT 6 32 2 2 2 2 2 2 2 2 SQUARE PERF GRILLE FILTER 9 5 X 1...

Reviews: