NuTone inVent AE110SL Installation And Use & Care Instructions Download Page 15

INSTR

UCCIONES DE INST

ALACIÓN,

 USO 

Y CUIDADO

 

PAR

TES DE SERVICIO

15

PIEZAS DE SERVICIO  

DEL MODELOS AE80SL, AE110SL  

1

2

3

5

7

6

8

4

DIAGRAMAS DE CABLEADO

Key No.

Part No.

Description

1

97019514 Cubierta

2

97019561
97020122

Conector de conducto - 4 pulg. (10 cm) (AE80SL)
Conector de conducto - 4 pulg. (10 cm) (AE110SL)

3

97020537 Conjunto del panel de cableado

4

97020538 Conjunto del panel de control de humedad 

5

97019785
97019786

Conjunto del soplador (AE80SL)
Conjunto del soplador (AE110SL)

6

99271529 Módulo LED

7

99140214 Ressort de parilla (2 nec.)

8

97019920 Conjunto de grille (incluye no. clave 6 y 7)

97019743 Bolsa de piezas (no mostrada)

OPCIÓN DE CONEXIÓN # 1

•  Cuando primer interruptor (1) está en ON, el 

ventilador funcionará automáticamente, en base a 

las condiciones de humedad ambiente.

•  Encienda el ventilador inmediatamente periodo 

de tiempo establecido (para controlar los olores), 

completando un ciclo primer interruptor.

•  Use segundo interruptor (2) para encender la luz 

de encendido / apagado.

•  Con la conexión opcional muestra, ventilador 

siempre estará en ON cuando la luz está encen-

dida.

NEG

CONTROL

DE

HUMEDAD

ÉCLAIRAGE

VENT. 

GRIS

MAR

NEG

ROJO 

NEG

NEG

BLC

BLC

BLC

BLC

BLC

TIERRA

TIERRA 

(2)

LÁMPARA

(ENCENDIDO/

APAGADO) 

(1)

VENTILADOR

(AUTO/

APAGADO) 

LÍNEA DE

ENTRADA

DE 120 VCA

COM

CONTROL DE 2 FUNCIONES 

(SE COMPRA POR SEPARADO)

BLC

TIERRA

INTERRUPTOR

UNIDAD

(Opcional)

OPCIÓN DE CONEXIÓN # 2

•  Cuando primer interruptor (1) está en ON, ventila-

dor funcionará automáticamente en función de las 

condiciones de humedad ambiente.

•  Encienda el ventilador inmediatamente (para contro-

lar los olores) mediante el uso de segundo interrup-

tor (2).

•  Utilice tercer interruptor (3) para encender la luz de 

encendido / apagado.

CONTROL DE 3-FUNCIONES

(SE COMPRA POR SEPARADO)

(3)

LÁMPARA

(ENCENDIDO/

APAGADO)

COM

(2)

VENTILADOR

(ENCENDIDO/

APAGADO)

(1)

VENTILADOR

AUTO

(AUTO/

APAGADO)

LÍNEA

DE

ENTRADA

120

VCA

INTERRUPTOR

BLC

TIERRA

NEG

NEG

BLC

UNIDAD

GRIS

NEG

BLC

TIERRA

NEG

ROJO

LÁMPARA

BLC

BLC

NEG

BLC

BRN

CONTROL

DE HUMIDAD

VENT.

BLC

Summary of Contents for inVent AE110SL

Page 1: ...y Sensing Fan Light Ventilador L mpara con sensor de humedad AE80SL AE110SL Model numbers N meros de modelo INSTALLATION AND USE CARE INSTRUCTIONS INSTRUCCIONES PARA INSTALACI N USO Y CUIDADO English...

Page 2: ...PA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring...

Page 3: ...ch back ON and fan will turn ON 50 60 80 70 10 5 60 15 40 20 30 50 HUMIDITY MINUTES HUMIDITY ADJUSTMENT HUMIDITY has been factory set at 80 for most shower applications If fan is not responding to cha...

Page 4: ...ing POWER CABLE Purchase separately OR Keep duct runs short 4 IN ROUND DUCT ALL INSTALLATIONS Start here IMPORTANT The ducting from this fan to the outside of the building has a strong effect on the a...

Page 5: ...ector to fan housing Push connector through opening from inside of housing Engage tabs and secure with screw from parts bag 4 Mount housing to ceiling structure TABS Make sure bottom of housing will b...

Page 6: ...Make sure that the wiring inside of the housing does not interfere with re installation of the blower 8 Install housing mask Place mask into housing opening to prevent drywall spray and construction d...

Page 7: ...connector Push connector ducting back through opening Engage tabs and secure with screw from parts bag 1 2 3 Install blower Finish ceiling then install grille See Steps 7 8 9 on Page 6 Step 8 is only...

Page 8: ...5 97019785 97019786 Blower Assembly AE80SL Blower Assembly AE110SL 6 99271529 LED Module 7 99140214 Grille Spring 2 req 8 97019920 Grille Assembly includes key no 6 7 97019743 Parts Bag not shown BLK...

Page 9: ...FPA la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades normativas...

Page 10: ...vez que se energice el ventilador de esta manera se mantendr prendido durante el periodo establecido en el temporizador Para energizar manualmente el ventilador 1 Si el interruptor de alimentaci n ya...

Page 11: ...del ventilador CABLE EL CTRICO Se compra por separado O Mantenga cortos los tramos de conductos CONDUCTO REDONDO DE 4 PULG 10 CM TODAS LAS INSTALACIONES Comience aqu IMPORTANTE Los conductos desde es...

Page 12: ...a trav s de la abertura desde el interior de la cubierta Enganche las leng etas y f jelas con los tornillos de la bolsa de piezas 4 Monte la cubierta en la estructura del cielo raso Aseg rese de que l...

Page 13: ...jetas de montaje planas contra la cubierta CONVERSI N PRECAUCI N Aseg rese de que el cableado dentro de la cubierta no interfiera con la reinstalaci n del soplador 8 Instale la tapa de la cubierta Col...

Page 14: ...r conducto de vuelta a trav s de la abertura Enganche las leng etas y f jelas con los tornillos de la bolsa de piezas 1 2 3 Instale el soplador Termine el cielo raso y a continuaci n instale la rejill...

Page 15: ...n ciclo primer interruptor Use segundo interruptor 2 para encender la luz de encendido apagado Con la conexi n opcional muestra ventilador siempre estar en ON cuando la luz est encen dida NEG CONTROL...

Page 16: ...e presentar una copia de la garant a limitada original por escrito entonces regir n los t rminos de la garant a limitada por escrito m s actualizada de la compa a para su producto en particular Las ga...

Reviews: