MoDEL GSVh1K
PERFoRMANCE SPECiFiCATioNS
iNSTALLATioN oPTioNS
Air-Flows (where applicable)
Fresh outdoor air intake (5” or 6”)
95 cfm with 5” ducts
105 cfm with 6” ducts
Stale indoor air drawn from the space
(8” duct)
270 cfm high speed
180 cfm low speed
Filter/Fresh air distributed to the
indoor space (8” duct)
270 cfm high speed
180 cfm low speed
installation (Typical Basement, Central Draw Point)
Fresh filtered air is distributed through the whole house. only
one outside connection is needed when using the Tandem™
transition and the AirDuo™ port*, simplifying the installation.
Filter Efficiency
Normal mode
99.97 @ 0.3 micron @ 180 cfm
Boost mode
99.82 @ 0.3 micron @ 270 cfm
Recirculation mode
99.97 @ 0.3 micron @ 180 cfm
unit Efficiency (Filtration)
Normal mode
> 87% @ 0.3 micron
Boost mode
> 85% @ 0.3 micron
Recirculation mode
> 87% @ 0.3 micron
*
Patent Pending
our exclusive Tandem™ transition never mixes stale
inside air (1) (coming from its duct unit (3)), and fresh air
from outside (2) (going through its unit duct (4)). Both
transition and AirSnap™ ports can be fitted with 5” and 6”
diameter insulated flexible ducts.
Also shown is our AirDuo™ exhaust/intake air vent, which
mounts on the exterior of the house. AirDuo™ is paintable
and uV-ray protected.
1
2
3
4
GENERAL SPECiFiCATioNS
•
For houses from up to 2,500 sq. ft.
•
HVI Rated of air flow: 105 cfm
•
Voltage: 120 VAC
•
Frequency: 60 hz
•
Power Consumed: 220 Watts (Watts in normal, boost
and recirculation modes)
•
Dimensions: 29.4” x 22.9” x 17.8”
•
Weight: 42 lbs
•
Shipping Weight: 57 lbs
•
Typical cross contamination: <3%
•
Warranty: 2 years on parts and labor
•
Materials (enclosure and insulation): ABS and EPS
•
Agency Compliances: UL, cUL, Certified HVI airflow,
and a
key component in the compliance to ASHRAE
62-1999
•
Wall control modes: Normal, Boost, and Recirculation