NuTone CV-352 Installation Manual Download Page 7

DIMENSIONAL CHART

MODEL

DIMENSION

CV-352

A

27"

B

7

3

4

"

C

6

1

2

"

D

13

5

8

"

7

POWER UNIT INSTALLATION

MOUNTING

See Figure 18.

1. Locate the power unit within six feet of a grounded electrical

outlet.

2. Drill 

3

16

" diameter pilot holes for the two (2) mounting screws in a

wall stud or strong support. See Figure 19. 

3. Tighten mounting screws. Leave approximately 

1

8

" to 

3

16

"

clearance between head of screw and wall.

4. Hang power unit onto mounting bolts. Make sure top keyhole

slot and lower slot in mounting bracket are engaged behind
mounting screws. Pull down to secure.

5. Remove dirt canister from power unit.
6. Install soil bag and securely replace dirt canister.

NOTE: Cyclonic model does not use a soil bag.

TUBING CONNECTIONS

1. Using rubber couplings and hose clamps, connect intake and

exhaust tubing to the power unit.

2. Connect intake tubing to lower intake tube on power unit.
3. Connect exhaust tubing to upper exhaust tube on the power unit.
4. Make sure all tubing connections are air tight.
5. The exhaust should not be vented into a wall, a ceiling or a

concealed space in the house. The exhaust line should be
terminated outside the home, using Model 393 Wall Cap or a
roof vent.

WIRING

See Figure 20.

Grounding Instructions – 

This appliance must be grounded. If

it should malfunction or breakdown, grounding provides a path of
least resistance for electric current to reduce the risk of electric
shock. This  appliance is equipped with a cord having an
equipment-grounding conductor and grounding plug. The plug
must be plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and ordinances.

Danger –

Improper connection of the equipment-grounding

conductor can result in a risk of electric shock. Check with a
qualified electrician or service person if you are in doubt as whether
the outlet is properly grounded. Do not modify the plug provided
with the appliance – if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.

This appliance is for use on a nominal 120-volt circuit and has a

grounding plug. Make sure that the appliance is connected to an
outlet having the same configuration as the plug. No adapter
should be used with this appliance.
1. Connect low voltage wire (18 gauge, 2-conductor, Model 376) to

two low voltage wires located on outside of the power unit.

2. The power unit is equipped with a six foot grounded cord. Plug

cord into 120 volt grounded receptacle.

12"

18"

“D”

“B” TOP

MOUNT

BOLT

“A”

OVERALL

HEIGHT

18" MINIMUM

ABOVE FLOOR

12" MINIMUM TO CEILING

FRONT VIEW

INTAKE

EXHAUST

“C”

INTAKE

EXHAUST

TOP VIEW

MINIMUM WALL CLEARANCE DIMENSIONS

FIGURE 18

TOP OF POWER UNIT

TOP

KEYHOLE SLOT

MOUNTING

BRACKET

LOWER

SLOT

11

1

/

2

"

FIGURE 19

INLET

INLET

INLET

NOTE: POWER UNIT
CONTROL LEADS ARE
TO BE CONNECTED TO
INLET LEADS WITH
SUITABLE WIRE
CONNECTORS.

WIRING

120vAC ELECTRICAL

OUTLET

MODEL 376 (18/2) WIRE

TO

OTHER
INLETS

INLET

LEADS

POWER

UNIT

POWER UNIT

CONTROL LEADS

POWER CORD

FIGURE 20

Summary of Contents for CV-352

Page 1: ...In 4 Installing the Tubing 4 Installation Hints 4 Tubing Installation 5 Wall Inlet Installation 6 Model 360 Wall Inlet 6 Model 330 Wall Inlet 6 Power Unit Installation 7 Dimensional Chart 7 Mounting 7...

Page 2: ...in the basement conveniently located for shop use and messy cleaning jobs The intake tubing runs up the basement wall and connects to the main trunk line which runs along the unfinished basement ceil...

Page 3: ...unit should be exhausted to the outside The exhaust should not be vented into a wall a ceiling or a concealed space in the house The exhaust line should be terminated outside the home using Model 393...

Page 4: ...nlet bracket See Figure 5A Spacer may be made from plywood masonite etc Contact cement may be used to hold spacer in place during assembly MODEL 329 SIDE MOUNTING FACE MOUNTING MODEL 361 23 8 113 16 F...

Page 5: ...eck for proper length 6 Refer to Figure 10 Apply cement Model 379 to outside of tubing Coat tubing approximately 1 back Take care to keep cement from inside of tube 7 Refer to Figure 11 Insert tubing...

Page 6: ...e back through hole in inlet bracket and make sure seal is secure between mounting bracket and flanged fitting 6 Refer to Figure 15 Place inlet into mounting bracket and secure NOTE When wall inlets a...

Page 7: ...ctric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounde...

Page 8: ...ften find a hollow space behind these appliances If this space lines up with an obstruction free interior wall above or a closet this might be a key to your installation In a ranch style home this key...

Page 9: ...e from mounting bracket Pull low voltage wire through hole in bracket and insert bracket into cutout Secure bracket to flanged fitting with four screws provided Be sure seal is secure between flange f...

Page 10: ...of inlet must be located at least 21 2 from wall to allow cover to be opened when hose is inserted 2 Determine direction of tubing and attach appropriate flanged fitting to mounting bracket with four...

Page 11: ...anual on off operation Check each wall inlet to be sure contacts activate power unit when hose is inserted A short piece of wire can be used to short contacts in wall inlet together to activate power...

Page 12: ...O REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF...

Reviews: