background image

3

1. P

REPARE

 

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. S

ELECT

 

INSTALLATION

 

TYPE

. . . . . . . . . . . . . . . . . . . . . . . . . 3 

3. B

UILD

 

FRAMEWORK

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4 I

NSTALL

 

UPPER

 

FLUE

 

MOUNTING

 

BRACKET

 

 

(

DUCTED

 

INSTALLATION

 

ONLY

) . . . . . . . . . . . . . . . . . . . . . . . . 4

5. I

NSTALL

 

PLENUM

 (

NON

-

DUCTED

 

INSTALLATION

 

ONLY

) . . . . . . . . . 4

6. R

EMOVE

 

GREASE

 

FILTER

(

S

) . . . . . . . . . . . . . . . . . . . . . . . . . 5

7. A

DJUST

 

THE

 

HOOD

 

MOUNTING

 

BRACKETS

. . . . . . . . . . . . . . . . 5

8. I

NSTALL

 

THE

 

HOOD

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

9. C

ONECT

 

WIRING

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

10. D

UCT

 

CONNECTION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

11. P

REPARE

 

THE

 

DECORATIVE

 

FLUE

. . . . . . . . . . . . . . . . . . . . . . 8

12. I

NSTALL

 

THE

 

DECORATIVE

 

FLUE

. . . . . . . . . . . . . . . . . . . . .  8-9

13. R

EINSTALL

 

GREASE

 

FILTER

(

S

)  . . . . . . . . . . . . . . . . . . . . . . . 9

14. O

PERATION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

15. C

ARE

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

16. R

EPLACEMENT

 

PARTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

17. W

ARRANTY

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

TABLE OF CONTENTS

1. PREPARE INSTALLATION

NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer.
Make sure that the following items are included:

- Hood
-  Decorative flue assembly (lower and upper flues)
-  Upper flue mounting bracket
-  Aluminum grease filter(s)
 

(1 for 24-in. width hood, 2 for 30-in. and 36-in. width hoods)

- Installation 

instructions

-  Parts bag:  6 M4 x 38 Phillips round head mounting screws, 

2 M4 x 12 Phillips round head screws, 
2 washers, 
3 wire connectors

 

Parts sold separately:

-  Ducts, elbows, wall and roof caps.
-  Optional flue extension for

 

ceilings of 9 ft. or more: models AEEW43SS (stainless 

steel) or AEEW43BLS (black stainless steel).

-  Non-duct kit model ARKEW43, mandatory for non-ducted installation.
NOTE: During installation, protect countertop and/or cooktop.

2.  SELECT INSTALLATION TYPE

2.1 N

ON

-D

UCTED

 I

NSTALLATION

 

The ARKEW43 non-duct kit is required for a non-ducted installation.

2.2 D

UCTED

 I

NSTALLATION

 

Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently. Long duct 
runs, elbows and transitions will reduce the performance of the hood. Use as few of 
them as possible. Larger ducting may be required for longer duct runs.
Install wall or roof cap. Connect 6” round metal ductwork to cap and work back 
towards the hood location. Use 2” metal foil duct tape to seal the joints.

2.3 A

LL

 I

NSTALLATIONS

 

The minimum hood distance above cooktop is 24”. A maximum of 30” above 

 

cooktop is recommended for best capture of cooking impurities.

 

Distances over 30” are at the installer and users discretion providing that ceiling 

 

height and decorative flue length allow it.

 

NOTE:  Ceilings of 9 ft. or more require flue extension model AEEW43SS (stainless

 

 

steel) or AEEW43BLS (black stainless steel).

6” R

OUND

DUCT

R

OOF

 

CAP

6” R

OUND

ELBOW

W

ALL

 

CAP

H

OOD

D

ECORATIVE

FLUE

HH0282A

24” 

MINIMUM

 

ABOVE

COOKING

 

SURFACE

    WARNING

!

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

HR0225A

(1) D

ECORATIVE

 

FLUE

     

ASSEMBLY

(1) U

PPER

 

FLUE

MOUNTING

 

BRACKET

(1 

OR

 2) G

REASE

 

FILTER

(

S

)

(6) M4 

X

 38 P

HILLIPS

 

ROUND

 

HEAD

 

SCREWS

 

(2) M4 

X

 12 P

HILLIPS

 

ROUND

 

HEAD

 

SCREWS

(2) W

ASHERS

(3) W

IRE

 

CONNECTORS

Summary of Contents for CHIMNEY EW43 Series

Page 1: ...Serial number 99046142C WWW BROAN COM WWW BROAN CA WW WW BR CHIMNEY RANGE HOOD EW43 Series INSTALLATION USE AND CARE MANUAL ...

Page 2: ...nly 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impeller keep drywall spray construction dust etc off power unit 4 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor conti...

Page 3: ... During installation protect countertop and or cooktop 2 SELECT INSTALLATION TYPE 2 1 NON DUCTED INSTALLATION The ARKEW43 non duct kit is required for a non ducted installation 2 2 DUCTED INSTALLATION Plan where and how the ductwork will be installed A straight short duct run will allow the hood to perform most efficiently Long duct runs elbows and transitions will reduce the performance of the ho...

Page 4: ...ps round head mounting screws in wall framing do not completely tighten the screws at this time 4 INSTALL UPPER FLUE MOUNTING BRACKET DUCTED INSTALLATION ONLY Center the upper flue mounting bracket with the center line previously drawn in step 3 and place it flush with the ceiling Use the upper flue mounting bracket as a template to mark the position of its screws Secure the upper flue bracket to ...

Page 5: ...nward Set filters aside NOTE There is only one filter on 24 in width hoods HD1155 8 INSTALL THE HOOD 1 Align the hood with the center line previously marked on the wall Gently lower the hood until its both mounting brackets securely engage the screws on the wall 2 Level the hood and completely tighten the screws on the wall 3 Secure the hood to the wall by inserting 2 M4 x 38 Phillips round head m...

Page 6: ...ckout from the junction box cover HR0226 Install a UL approved strain relief not included on the house power cable at 4 from the cable end Run the power cable in the junction box cover opening then use the strain relief to secure the house power cable to the junction box cover Connect power cable to range hood wiring using included wire connectors Connect BLACK to BLACK WHITE to WHITE and GREEN or...

Page 7: ... cap and 90 elbow over duct collar then install the 90 elbow over the adapter damper on the hood Use metal foil duct tape to seal the joints HJ0201 NON DUCTED INSTALLATION Remove and discard the damper flaps from the adapter on top of hood Measure the length of 6 round flexible duct included in the non duct kit required from the top of the hood to the plenum Slide the 6 round flexible metal duct o...

Page 8: ...oth lower and upper flues are included with the hood but for ceilings of 9 ft or more discard the provided lower and upper flues and use the optional flue extension part no AEEW43SS stainless steel or AEEW43BLS black stainless steel sold separately Remove the upper flue from inside the lower flue Remove protective plastic film covering the lower flue only 12 INSTALL THE DECORATIVE FLUE Carefully s...

Page 9: ...e filters align rear filter tabs with slots in the hood Pull down the metal latch tab push each filter into position and release Make sure filters are securely engaged after installation HD1161 HA0145 A B HO0293 NON DUCTED INSTALLATION Slide up the upper flue until it is aligned with the plenum Secure the upper flue to the plenum using 2 M4 x 12 Phillips round head screws Remove protective plastic...

Page 10: ...to clean the filter s Grease filter s are dishwasher safe Clean all metal filters in the dishwasher using a non phosphate detergent Discoloration of the filters may occur if using phosphate detergents or as a result of local water conditions but this will not affect filter performance This discoloration is not covered by the warranty To minimize or prevent discoloration hand wash filters using a m...

Page 11: ... WITH BRACKET 1 1 1 S97021441 DECORATIVE UPPER AND LOWER FLUES BLACK STAINLESS STEEL WITH BRACKET 1 1 2 S99527461 DAMPER ASSEMBLY 1 1 1 3 S99840026 JUNCTION BOX 1 1 1 4 S99271684 POWER CABLE 1 1 1 5 S97021443 POWER UNIT USER INTERFACE 1 1 1 6 S99010479 LED MODULE 1 1 1 7 S97021444 MOTOR AND BLOWER ASSEMBLY 1 1 1 8 S99010473 NON DUCT RECIRCULATION FILTERS SET OF 2 1 1 S99010474 NON DUCT RECIRCULATI...

Page 12: ...r freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves the right to utilize reconditioned refurbished repaired or remanufactured Products or parts in the warranty repair or rep...