NuTone ALLURE WS3 Series Instruction Manual Download Page 2

Page 2

ALLURE

®

 WS3 SERIES

RANGE HOOD  

CABINET

BOTTOM

CABINET FRONT

HORIZONTAL DUCT

ACCESS HOLE

5¼"

5¼"

7½"

1/8

"

¾"

13

15/16

"

(30" hood)

16

15/16

"

(36" hood)

13

15/16

"

(30" hood)

HOOD

MOUNTING

SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in wall)

3¾"

16

15/16

"

(36" hood)

CENTER

LINE

WOOD SHIMS

(recessed-bottom

cabinets only)

19

15/16

"

(42" hood)

19

15/16

"

(42" hood)

SOFFIT

24" - 30" ABOVE
COOKING SURFACE

CABINET

3¼" X 10" DUCT
(For horizontal discharge)

WALL CAP

ROOF CAP

3¼" X 10"

(For vertical 

discharge)

HOUSE WIRING
(Top or Back of hood)

HOOD

HOOD

PREPARE HOOD LOCATION

PREPARE THE  HOOD

Remove tape holding 

Filters

 in place. Pull down on filter 

tabs or finger holes and lift filters out. Set filters aside.

FILTERS

Determine whether hood will discharge vertically (3¼” x 10”), 
or horizontally (3¼” x 10” only). For vertical or horizontal dis-
charge, run ductwork between the hood location and a roof 
cap or wall cap. For best results, use a minimum number of 
transitons and elbows.

Use diagrams, below, for proper placement of ductwork and 
electrical cutout in cabinet or wall. For a non-ducted installa-
tion, DO NOT cut a duct access hole.

Run house wiring between service panel and hood location.

VERTICAL DUCT

ACCESS HOLE

1¼"

1½"

10½"

5¼"

5¼"

CENTER

LINE

HOOD MOUNTING SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in cabinet bottom)

WOOD SHIMS

(recessed-bottom

cabinets only)

CABINET FRONT

CABINET BOTTOM

13

15/16

"

(30" hood)

16

15/16

"

(36" hood)

7½"

5"

2"

19

15/16

"

(42" hood)

13

15/16

"

(30" hood)

16

15/16

"

(36" hood)

19

15/16

"

(42" hood)

3¼” X 10” 

VERTICAL DUCTING

3¼” X 10” 

HORIZONTAL DUCTING

2 Remove 

Teflon

®

-coated bottom cover from hood.

  Set 

cover and mounting screws aside.

TEFLON

®

-

COATED 

BOTTOM 

COVER

(Held in 

place with 

2 screws)

Teflon

®

 is a registered trademark of DuPont.

3 Remove 

Damper/Duct Connector 

from inside the hood. 

Set connector aside - with mounting screws and parts bag.

DAMPER/

DUCT

CONNECTOR

Summary of Contents for ALLURE WS3 Series

Page 1: ...e cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting l...

Page 2: ...ork between the hood location and a roof cap or wall cap For best results use a minimum number of transitons and elbows 2 Use diagrams below for proper placement of ductwork and electrical cutout in c...

Page 3: ...SCREWS LIGHT PANEL 2 8 SCREWS 6 Remove Air Chute held in place with one 1 screw NOTE Be care ful not to discon nect any wires AIR CHUTE 8 Rotate baffle Reinsert baffle into air chute as shown so that...

Page 4: ...Discharge TOP RECTANGULAR DUCT KNOCKOUT Remove for 3 x 10 Vertical 12 Horizontal Discharge Only Remove the Plate in front of the horizontal discharge knockout Cut the Ties lift plate out and discard...

Page 5: ...4 Install 2 PAR20 50 W Maximum Halogen Bulbs or 2 R16 40 W Maximum Incandescent Bulbs Purchase bulbs separately CAUTION Bulbs may be hot Refer to bulb packaging for further information CONNECT WIRING...

Page 6: ...d au tomatically adjust the fan to the appropriate setting 1 If the fan is on the Heat Sentry system will increase the fan setting when the temperature is elevated If the temperature continues to rise...

Page 7: ...R111630 Lamp Socket Assembly 23 R7201731 Light Panel 30 in White R7201751 Light Panel 36 in White R7201771 Light Panel 42 in White R7201734 Light Panel 30 in Black R7201754 Light Panel 36 in Black R7...

Page 8: ...mplied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply...

Reviews: