MOUNTING THE HOUSING

Note: When installing in existing construction, refer to page 3

Mounting Using Mounting Tabs

Refer to Figure 2.

1.   Locate fan housing next to ceiling joist.

2.   Use wood screws (not provided) to loosely attach housing to ceiling joist 

through keyhole slots in mounting tabs.

3.   Adjust housing so that it will be flush with finished ceiling. For the grille to fit 

properly, the housing’s rim must not extend beyond finished ceiling surface.

4.   When housing is properly adjusted, tighten screws in slots.

Mounting Using Hanger Bars

Refer to Figure 3.

1.   Insert hanger bars in slots provded in housing.

2.   Locate fan housing between joists so that the bottom of the housing is even 

with the planned finished ceiling.

3.   Use screws or nails (not provided) to secure hanger bars to ceiling joists.

INSTALLING DUCTWORK

1.   

Refer to Figure 1. 

Place duct collar over flanges at discharge opening of fan. 

Secure collar by snapping tabs into slots in flanges.

2.   Run 4” round duct from fan’s discharge opening to the outside and terminate.

WIRING

All wiring must comply with local codes and unit must be properly 

grounded.

1.   Run 120vAC house wiring (with ground) from wall switches to fan location.

2.   Insert and secure an approved box connector into wiring entrance hole.

3.   Pull wires through box connector and into junction box. Tighten box connector.

4.   

Refer to Figures 4A and 4B.

 If a single switch will be used to control both the 

fan and the light, make wiring connections as shown in Figure 4A. If a double 

switch will be used for separate control of the fan and light, make connections 

as shown in Figure 4B.

5.   Connect the green (or bare) ground wire to the green ground lead. 

FIGURE 3

FIGURE 2

FIGURE 4A

Duct Collar

FAN

RECEPTACLE

LIGHT

RECEPTACLE

Flanges

Wiring 

Knockouts

Mounting 

Tabs

Bottom 

Rim

FIGURE 4B

SWITCH

GROUND

SCREW

120 VAC

WHITE

B

L

K

B

L

K

WHITE

WHITE

BLK

FAN

RECEPTACLE

LIGHT

RECEPTACLE

FAN

SWITCH

GROUND

SCREW

120 VAC

WHITE

B

L

A

C

K

B

L

A

C

K

WHITE

WHITE

LIGHT

SWITCH

Summary of Contents for 8663RFT

Page 1: ...s must always be vented to the outdoors E If this unit is to be installed over a tub or shower it must be marked as appropriate for the application F NEVER place a switch where it can be reached from...

Page 2: ...ng of fan Secure collar by snapping tabs into slots in flanges 2 Run 4 round duct from fan s discharge opening to the outside and terminate WIRING All wiring must comply with local codes and unit must...

Page 3: ...xisting wiring plumbing etc and that the wiring and ducting can be run to the desired location It will be neces sary to use flexible duct when installing the unit from below 1 The fan must be mounted...

Page 4: ...e C Lorsque vous coupez ou percez dans un mur ou un plafond n ab mez pas le c blage lectrique ou tout autre installation encastr e D Les ventilateurs avec gaine doivent toujours avoir une une vacuatio...

Page 5: ...ttes dans les fentes des collerettes 2 Voir Figure 3 Faire passer une gaine ronde de 4 po de l ouverture d vacuation du ventilateur l ext rieur et proc der aux finitions 3 Raccorder la gaine au collie...

Page 6: ...us pour fixer les barreaux de montage aux solives du plafond 4 Proc dez l installation des conduits d a ration et du c blage comme d crit ci dessus INSTALLATION PARTIR DE LA ZONE SE TROUVANT EN DESSOU...

Page 7: ...do desde la ba era o ducha G Para instalaci n en techos inclindos a una pendiente de 12 12 H La canalizaci n debe se alar para arriba PARA OBTENER MEJORES RESULTADOS Cuando instale la l mpara ventilad...

Page 8: ...as de las bridas 2 Pase el conducto redondo de 4 desde la abertura de descarga del ventilador al exterior y termine CABLEADO Todo el cableado debe cumplir con los c digos locales y la unidad debe esta...

Page 9: ...existente plomer a etc y que tanto los con ductos como el cableado puedan traerse hasta el lugar desado Ser necesario usar conductos flexibles cuando la unidad se instala desde abajo 1 El ventilador s...

Page 10: ...E TOUT PRODUIT OU PI CE D FECTUEUX CONSTITUE LE SEUL REM DE DE L ACHETEUR EN VERTU DE CETTE GARANTIE Broan NuTone NE PEUT TRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS CONS CUTIFS OU SP CIAUX ATTRIBUAB...

Page 11: ...Ground Clip 5 100603000 Blower Wheel 6 101049000 Reflector 7 85936000 Lampholder Bracket 8 97016879 Lampholder Ballast Plug Assembly 9 30652000 Duct Adapter Assembly 10 44388000 Hanger Bar 1 11 970179...

Page 12: ...99044360A...

Reviews: