NuTone 82W Installation Instructions Download Page 1

1.  For bathroom applications the Control should be placed at a level to detect 

humidity. Placing the Control directly above a heater or near drafts is not 

recommended.

2.  It is recommended that in large spaces the Broan-NuTone Premium Humidity 

Sensing Wall Control be placed within close proximity to the shower/tub/

sink (main source of the humidity/steam) to most effectively measure/detect 
excess humidity.

INSTALLATION

1. Turn power (circuit breaker) OFF.
2. Remove existing switch cover and switch from wall box.
3. Disconnect and label switch wires.
4. Connect Black (HOT), White (Neutral - Required) and Black or Red (Load) 
wires to Humidity Wall Control Switch.
5. Install Humidity Control in wall box, and secure with the two attached screws.
6. Install wall plate (not provided) on Humidity Control, and secure with the two 
captive screws.
7. Turn power (circuit breaker) ON. Note: When power is applied, the Model 82W 
requires approx. 30 seconds to boot up and be ready to function.
8. Remove lower switch cover and adjust initial control mode potentiometers.

LOWER COVER REMOVAL AND INSTALL

Installation Instructions

INCLUDED

Switch
Instruction Sheet

Note: Wall plate not included – Use Broan Part No. S97012925 (or equivalent)

CONTROL SPECIFICATIONS

•  cULus listed
•  120 VAC 60 Hz Line Power
•  9A Max. Total Load (Fan + Lamp)
•  When used in combination with fan/light fixtures that are switched together, 
  the device is rated for the following lamps: 600W Incandescent, 150W    
  LED, 150W CFL, or 400VA Inductive Ballasted Fluorescent Lamps
•  Typical wire sizes: 12AWG (MAX) or 14AWG solid or stranded copper wire
•  Operating temperature: 0-50°C (32-122°F)

SAFETY

Before installing control, switch power off at service panel and lock the service 
disconnecting means to prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel.

Installation work and electrical wiring must be done by a qualified person(s) in 
accordance with all applicable codes and standards.

1.  Use copper wire only.
2.  CAUTION: Risk of Electric Shock - More than one disconnect switch may be 

required to de-energize the equipment before servicing.

3.  WARNING: This device shall not be used in combination with a wall switch 

controlling a receptacle.

4.  Install only in a UL Listed junction box sized 50.8 x 76.2 x 76.2 mm (2.0 x 3.0 x 

3.0 in.) or larger, minimum volume 295 CM

3

 (18.0 in

3

).

5.  Requires a neutral wire for operation.
6.  Note: When power is applied, the Model 82W requires approx. 30 seconds to 

boot up and be ready to function.

 

A

   Removal:

•  Grasp sides of lower cover and 

pull straight outward. 

 

B

   Install:

•  Align tabs on cover with holes 

in metal panel and push 
straight inward

B

A

 

A

   Démontage : 

•  Agrippez les côtés du capot 

inférieur et tirez en ligne droite.  

 

B

   Installation :

•  Alignez les ergots du capot 

sur les trous du panneau 
métallique et poussez vers 
l’intérieur.

B

A

B

A

A

ON/OFF Switch and LED (Fan ON/OFF Indicator)
Ground Wire
Potentiometer Adjustable Dial Settings - Remove lower cover on control face

B

C

C

(Factory default settings shown.)

Model 82W 

Premium Humidity Sensing Wall 
Control

WIRE INSTALLATION & WIRING DIAGRAM

INSTALLATION DES FILS ET SCHÉMA DE CÂBLAGE

CONTROL MODE SETTINGS (POTENTIOMETER ADJUSTMENTS) 

AUTO SENSE / RH% / CYCLE Potentiometer:

•  AUTO SENSE Mode:

  The control has an automatic sensing mode 

(AUTO SENSE

) that senses 

increasing changes in humidity level (i.e. Sense on Rise). Once the threshold 
is met, the bath fan will activate within 2 minutes with the device located within 
8 feet from the humidity source (e.g. shower head or faucet). Fan activation 
may take longer if the Control is located further than 8 feet from the humidity 
source. The fan will remain ON based on the user adjustable 

TIME

 function 

(See TIME Potentiometer description).

 TIME:

 User adjustable from 10-60 minutes per hour, in 10 minute increments

  AUTO SENSE / RH% / CYCLE:

 AUTO SENSE

 SENSITIVITY:

 Active; user adjustable from LO to HI

  Control Function:

  SENSE ON RISE is ACTIVE
  SENSITIVITY is ACTIVE

•  CYCLE (Air Cycling) Mode:

  The control provides a pre-set ventilation ON TIME for meeting continuous 

ventilation codes. After the initial ON time is set by manually turning the fan ON, 
the control will provide continuous activation cycles every hour. Also, Sense on 
Rise is active in the CYCLE mode, so if the control is in the “Fan OFF” portion 
of the cycle and it senses a rise in humidity it will bypass the remainder of the 
OFF cycle and start a new ON cycle with a time duration equal to the TIME 
potentiometer setting.

  To calculate the applicable TIME potentiometer setting, use the following formula: 

TIME potentiometer setting = (required CFM

1

 ÷ fan CFM) x 60 

 

1

 

from ASHRAE 62.2 formula/table (based on square footage and number of 

bedrooms)

 TIME:

 User adjustable from 10-60 minutes per hour, in 10 minute increments

  AUTO SENSE / RH% / CYCLE:

 CYCLE

 SENSITIVITY:

 Active; user adjustable from LO to HI

  Control Function:

  SENSE ON RISE is ACTIVE
  SENSITIVITY is ACTIVE

•  RH% (Humidistat) Mode:

  The control has a 

RH%

 mode with a user adjustable threshold relative 

humidity level. The RH% setting can be adjusted from 20 to 80% RH in 10% 
RH increments. Once the threshold is met, or if SENSE ON RISE detects an 
increase in humidity, the connected fan should activate within 2 minutes with 
the device located within 8 feet from the humidity source (e.g. shower head or 
faucet). Fan activation may take longer if the Control is located further than 
8 feet from the humidity source. The fan will remain ON based on the user 
adjustable

 TIME

 function.

 TIME:

 User adjustable from 10-60 minutes per hour, in 10 minute increments

  AUTO SENSE / RH% / CYCLE:

 RH%; user adjustable from 20-80% in 10% RH 

increments.

 SENSITIVITY:

 Inactive

  Control Function:

 

  SENSE ON RISE is ACTIVE
  SENSITIVITY is INACTIVE.
  When room humidity reaches 

RH%

 potentiometer setting:

- Fan (and LED) will turn ON.
- When timer times out, Fan (and LED) will turn OFF until another event 
occurs, or is still occurring (i.e. ambient humidity is still at or above RH% 
setpoint, ambient humidity reaches the RH% setpoint again or Sense on 
Rise detects a rise in humidity level).

TIME Potentiometer:

The TIME potentiometer is used to set the fan run time every time the fan 
turns ON. It can be adjusted to run between 10 and 60 minutes, in 10 minute 
increments. In CYCLE mode the TIME selection is the portion of each hour that 
the fan will run, and the countdown begins when CYCLE mode is selected and 
the fan turns ON. In MANUAL mode the TIME countdown begins when the fan is 
turned ON using the ON/OFF switch. In AUTO SENSE and RH% modes the TIME 
countdown begins when the relative humidity stops rising.

SENSITIVITY Potentiometer:

The SENSITIVITY potentiometer is used to adjust the controls’ sensitivity to am-
bient humidified air and to the size of the room. In a low humidity environment 
and/or large room, it may be necessary to adjust the SENSITIVITY potentiometer 
to a higher setting (MED to HI) to increase the control sensitivity for humidity 
detection. In a high humidity environment and/or small room, it may be necessary 
to adjust the SENSITIVITY potentiometer to a lower setting (LO to MED) to reduce 
the control sensitivity for humidity detection and to prevent undesired activations.

MANUAL OPERATION MODE

 

Note: Regardless of all other settings, the front panel blue LED 

 

will always be ON when fan is ON, and OFF when fan is OFF.

The control has a manual operation mode with the ability to turn the fan ON or 
OFF at the user’s discretion. Press and release the lower control switch to turn 
the fan ON or OFF.

In addition to manually turning the fan OFF, the manual mode also utilizes the 
automatic OFF function with user adjustable fan ON time duration, as described 
previously in the TIME Potentiometer section. With this feature the user can man-
ually turn the fan ON and not be concerned about manually turning the fan back 
OFF, because the TIME function will turn the fan OFF automatically.

The manual mode will override the AUTO SENSE / RH% / CYCLE modes when-
ever they are active. This mode setting will turn OFF all user adjustable set points, 
with the exception of the 

TIME

 setting, until the switch is manually turned OFF 

or the switch turns OFF automatically due to the TIME countdown, at which time 
the unit will return to the previous modes setting(s) following a 5-minute delay.

In other words, if the fan is turned ON manually, and then turned OFF manually (or 
due to the TIME countdown completing its cycle), and if the previous setting was 

RH%

, then following a 5-minute delay the control will return to the 

RH%

 setting 

and turn the fan ON if the 

RH

 set point is reached, surpassed, or if the Control 

senses the appropriate rate of rise of humidity.

If the previous setting was 

AUTO

, the control will turn the fan ON (after the 5-min-

ute delay) if the control senses the appropriate rate of rise of humidity.

TIME:

 User adjustable from 10-60 minutes per hour, in 10 minute increments

AUTO SENSE / RH% / CYCLE:

 Inactive

SENSITIVITY:

 Inactive

Control Function:

Regardless of the MODE the unit is in, pressing the front panel switch overrides 
that mode to immediately turn the Fan ON if it was OFF, or OFF if it was ON.

 

 

               Limited Warranty 

Warranty Period and Exclusions:

 Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser 

of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship 

for a period of one (1) year from the date of original purchase. 

The limited warranty period for any replacement parts provided by the Company and for any Products repaired or 

replaced under this limited warranty shall be the remainder of the original warranty period. 

This warranty does not cover repellent cartridges or repellent cartridge refills that may be purchased separately and 

installed with the Product. This warranty also does not cover (a) normal maintenance and service, (b) normal wear 

and tear, (c) any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, 

improper or insufficient maintenance, storage or repair (other than repair by the Company), (d) damage caused by 

faulty installation, or installation or use contrary to recommendations or instructions, (e) damage caused by exposure to 

salt air (f) damage in transit, (g) natural wear of finish, (h) Products in commercial or nonresidential use, or (i) damage 

caused by fire, flood or other act of God. This warranty covers only Products sold to original consumers in the United 

States by the Company or U.S. distributors authorized by the Company. 

This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser. 

No Other Warranties:

 This Limited Warranty contains the Company’s sole obligation and your sole remedy for 

defective products. The foregoing warranties are exclusive and in lieu of any other warranties, express or implied. 

THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES, AND DISCLAIMS 

AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

 To the extent that applicable law prohibits 

the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the period specified for 

the express warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the above 

limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and 

shall not be construed as an express warranty. 

Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and 

valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective only 

to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining 

provisions of the Limited Warranty. 

Remedy:

 During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, 

or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered by and 

in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product 

or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation and shipping, 

insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send 

the Product or part to the Company, as instructed by the Company, you must properly pack the Product or part—the 

Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, 

repaired or remanufactured Products or parts in the warranty repair or replacement process. Such Products and parts 

will be comparable in function and performance to an original Product or part and warranted for the remainder of the 

original warranty period. 

Exclusion of Damages:

 

THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR 

REPLACE, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS 

LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL 

NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF 

OR IN CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE. 

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation 

or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, 

which vary from state to state. 
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility 

and does not include the cost of field service travel and living expenses. 
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited 

warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend or revive 

the warranty. 
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, 

except for those incurred with the Company’s prior written permission. 

How to Obtain Warranty Service:

 To qualify for warranty service, you must (a) notify the Company at the address or 

telephone number stated below within seven (7) days of discovering the covered defect, (b) give the model number and 

part identification and (c) describe the nature of any defect in the Product or part. At the time of requesting warranty 

service, you must present evidence of the original purchase date. If you cannot provide a copy of the original written 

limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will 

control. The most current limited written warranties for the Company’s products can be found at www.broan.com . 
Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.broan.com 800-637-1453

1.  Pour les applications de salles de bain, la commande doit être installée à un certain 

niveau pour détecter l’humidité. Il n’est pas recommandé d’installer la commande 

directement au-dessus d’un appareil de chauffage ou près d’un tirage.

2.  Dans les grands espaces, il est recommandé d’installer la super commande 

murale de détection d’humidité Broan-NuTone à proximité de la douche/de la 

baignoire/de l’évier (principale source d’humidité/de vapeur) afin de mesurer/

détecter l’humidité de la manière la plus efficace possible. 

INSTALLATION

1.  Coupez l’alimentation (disjoncteur).

2. Déposez le couvercle de l’interrupteur et l’interrupteur de la boîte murale.

3. Déconnectez et étiquetez les fils de l’interrupteur.

4. Connectez les fils noir (CHAUD), blanc (NEUTRE - requis) et noir ou rouge 

(CHARGE) à l’interrupteur de la commande murale de détection d’humidité.

5. Installez la commande de détection d’humidité dans la boîte murale et fixez-les à 

l’aide des deux vis fournies.

6. Installez la plaque murale (non fournie) sur la commande de détection d’humidité 

et fixez-les à l’aide des deux vis imperdables.

7. Rétablissez le courant (au disjoncteur). Remarque : Lorsque le courant est 

rétabli, le Modèle 82W prend environ 30 secondes pour se réinitialiser et être prêt à 

fonctionner.

8. Retirez le couvercle inférieur de l’interrupteur et effectuez les premiers réglages 

du mode de contrôle du potentiomètre.

RETRAIT ET INSTALLATION DU COUVERCLE INFÉRIEUR

Instructions d’installation

INCLUS

Interrupteur
Fiche d’instructions

Remarque : Plaque murale non incluse, utilisez la pièce Broan N°S97012925 
(ou l’équivalent)

SPÉCIFICATIONS DE LA COMMANDE

•  Homologuée cULus
•  Puissance de ligne 120 VCA 60 Hz
•  9A cax. charge totale (venti ampoule)
•  

Lorsqu’il est utilisé conjointement avec un ventilateur/des luminaires branchés 
ensemble, cet appareil est conçu pour les lampes suivantes : une ampoule 
à incandescence de 600 W, DEL de 150 W, CFL de 150 W, des lampes 
fluorescentes à ballast inductif de 400 VA

•  Calibre type des fils : fil de cuivre massif ou tressé 12AWG (max.) ou 14AWG
•  Température de fonctionnement : 0-50°C (32-122°F)

SÉCURITÉ

Avant d’installer la commande, coupez l’alimentation électrique sur le panneau 
de service et verrouillez les dispositifs de sectionnement pour empêcher la 
remise sous tension accidentelle. Lorsque vous ne pouvez pas verrouiller les 
dispositifs de sectionnement, serrez à fond un dispositif d’avertissement bien 
visible, comme une étiquette sur le panneau de service.

Les travaux d’installation et le câblage électrique doivent être effectués par 
une personne qualifiée conformément aux codes et normes applicables.

1.  Utilisez uniquement du fil de cuivre.
2.  MISE EN GARDE : risque de choc électrique. Il peut s’avérer nécessaire d’utiliser 

plus d’un sectionneur pour mettre l’équipement hors tension avant d’effectuer les 
travaux d’entretien.

3.  AVERTISSEMENT : cet appareil ne doit pas être utilisé en association avec un 

interrupteur mural qui contrôle une prise.

4.  Installez uniquement une boîte de jonction homologuée UL aux dimensions 

suivantes 50,8 x 76,2 x 76,2 mm (2,0 x 3,0 x 3,0 po.) ou supérieures et d’un 
volume minimum de 295 CM

3

 (18,0 po

3

).

5.  Nécessite un câble neutre pour l’opération.
6.  Remarque : Lorsque le courant est rétabli, le Modèle 82W prend environ 

30 secondes pour se réinitialiser et être prêt à fonctionner.

B

A

A

Interrupteur MARCHE/ARRÊT et DEL (voyant MARCHE/ARRÊT du ventilateur)
Conducteur de terre
Paramètres réglables du cadran du potentiomètre – retirez le couvercle inférieur 
sur la face de la commande

B

C

C

(Réglages par défaut en usine affichés.)

Modèle 82W 

Super commande murale de 
détection d’humidité

RÉGLAGES DU MODE DE CONTRÔLE (RÉGLAGES DU POTENTIOMÈTRE) 

POTENTIOMÈTRE DE DÉTECTION AUTOMATIQUE/RH%/DE CYCLE :

•  Mode DÉTECTION AUTOMATIQUE :
 

La commande dispose d’un mode de détection automatique  

(DÉTECTION 

AUTOMATIQUE

) qui détecte les changements croissants du niveau d’humidité 

(c-à-d. détection en cas d’augmentation). Une fois le seuil atteint, le ventilateur 

de bain s’active dans un délai de 2 minutes, si la commande est située à 8 

pieds de la source d’humidité (p.ex. pomme ou robinet de douche) L’activation 

du ventilateur peut durer plus longtemps si la commande est située à plus de 

8 pieds de la source d’humidité. Le ventilateur reste ALLUMÉ en fonction de la 

TEMPORISATION 

réglée par l’utilisateur (voir description du potentiomètre de 

TEMPORISATION)

.

  TEMPORISATION :

 Réglable entre 10 et 60 minutes par heure, par incréments de  

10 minutes

  DÉTECTION AUTOMATIQUE/ RH%/CYCLE :

 DÉTECTION AUTOMATIQUE

 SENSIBILITÉ :

 Activée ; réglable entre les paramètres BAS et HAUT

  Fonction de la commande :

  DÉTECTION EN CAS D’AUGMENTATION EST ACTIVÉE

  SENSIBILITÉ EST ACTIVÉE

•  Mode CYCLE (circulation de l’air) :

 

  Pour répondre aux codes de ventilation continue, la commande fournit une 

DURÉE de fonctionnement préréglée de la ventilation. Après le réglage initial de 

la durée de fonctionnement qui s’effectue manuellement en mettant le ventilateur 

en marche, la commande fournit des cycles d’activation continus toutes les 

heures. En outre, la détection en cas d’augmentation est activée en mode CYCLE; 

par conséquent, si la commande se trouve dans la partie « VENTILATEUR À 

L’ARRÊT » du cycle et elle détecte une augmentation de l’humidité, la commande 

va ignorer le restant du cycle ARRÊT et démarrer un nouveau cycle MARCHE 

avec une durée égale au réglage du potentiomètre de temporisation.

  Pour calculer la DURÉE applicable du potentiomètre de temporisation, utilisez 

la formule suivante : DURÉE réglée sur le potentiomètre = (PCM

1

 requis ÷ PCM 

ventilateur) x 60

 

1

 

D’après la formule/table 62.2 de l’ASHRAE (selon la superficie en pieds carrés 

et le nombre de chambres)

  TEMPORISATION :

 Réglable entre 10 et 60 minutes par heure, par incréments 

de 10 minutes

  DÉTECTION AUTOMATIQUE/ RH%/CYCLE :

 CYCLE

 SENSIBILITÉ : 

Activée; réglable entre les paramètres BAS et HAUT

  Fonction de la commande :

  DÉTECTION EN CAS D’AUGMENTATION EST ACTIVÉE

  SENSIBILITÉ EST ACTIVÉE

•  Mode RH% (humidostat) :

  La commande dispose d’un mode 

RH%

 et d’un seuil réglable du niveau 

d’humidité relative. Il est possible de régler le paramètre RH% entre 20 et 

80  % RH en incréments de 10 % d’humidité relative. Une fois le seuil atteint 

ou si la DÉTECTION EN CAS D’AUGMENTATION détecte une augmentation 

de l’humidité, le ventilateur raccordé s’active dans un délai de 2 minutes si la 

commande est située à 8 pieds de la source d’humidité (p. ex. pomme ou robinet 

de douche). L’activation du ventilateur peut durer plus longtemps si la commande 

est située à plus de 8 pieds de la source d’humidité. Le ventilateur reste allumé 

en fonction de la 

 TEMPORISATION

 réglée par l’utilisateur.

  TEMPORISATION :

 Réglable entre 10 et 60 minutes par heure, par incréments 

de 10 minutes

  DÉTECTION AUTOMATIQUE/ RH%/CYCLE :

 RH% ; réglable entre 20-80 % en 

incréments de 10 % d’humidité relative.

 SENSIBILITÉ : 

Désactivée

  Fonction de la commande : 

  DÉTECTION EN CAS D’AUGMENTATION EST ACTIVÉE

  La SENSIBILITÉ est DÉSACTIVÉE.
 

Lorsque l’humidité ambiante atteint le paramètre 

RH%

 du potentiomètre :

- Le ventilateur (et le voyant DEL) sont allumés

- Lorsque le temporisateur expire, le ventilateur (et le voyant DEL) 

s’éteignent jusqu’à la prochaine occurrence (c.à.d. si l’humidité ambiante 

est toujours égale ou supérieure au point de consigne RH%, l’humidité 

ambiante atteint à nouveau le point de consigne RH% ou si Détection en 

cas d’augmentation capte une élévation du niveau d’humidité)

HEURE

DÉTECTION  

AUTOMATIQUE

CYCLE  

(MIN/HR)

SENSIBILITÉ 

MOY

Wire terminals accept up to #12 AWG MAX solid and stranded wire.
1.  Remove combination Screw/Washer from terminal.
2.  Wrap stripped end of Wire around Screw thread - under Washer.
3.  Re-install Screw/Washer - making sure Wire remains under Washer. Tighten 

terminal screws to 1.8 - 2.2 N-m (15.9 - 19.5 in.lb.).

4.  Note: Screw/Washer 

are not designed for 
straight insertion of 
stripped wire. Use 
only wire formed 
into a “J” loop and 
wrapped around 
Screw thread for 
proper mechanical 
and electrical 
connection.

Les bornes de connexion acceptent des fils de cuivre massif ou tressé d’un 
calibre de 12 AWG au maximum. 
1.  Enlevez l’ensemble de vis et rondelle de la borne. 
2.  Enroulez le fil dénudé autour de la vis, sous la rondelle. 
3.  Reposez l’ensemble de vis et rondelle, en vous assurant que le fil reste 

bien sous la rondelle. Serrez les vis des 
bornes à un couple de 1,8 à 2,2 N-m 
(15,9 à 19,5 po-lb). 

4.  Remarque : Les 

ensembles de 
vis et rondelle ne 
sont pas conçus 
pour insérer le fil 
dénudé en ligne 
droite. N’utilisez 
que des fils dont 
l’extrémité en 
forme de « J » est 
placée sur les filets 
des vis pour de 
bonnes connexions 
mécaniques et 
électriques.

Wire

3/4” (1.9 cm)

Washer

Screw

Wire under Washer

& Screw Head

Cable

3/4 po. (1.9cm)

Rondelle

Vis

Fil sous la rondelle 

et la tête de vis

NOIR

BLAN

C

TERRE

VENTILATEUR

B O Î T E   D E   D I S T R I B U T I O N

1 2 0  V A C

A L I G N E R

BLANC

TERRE

NOIR

NOIR

NOIR

VENTILATEUR

(CHARGE)

CHAUD

(LIGNE)

NEUTRE

TERRE

BLANC

VERT

COMMANDE 
D’HUMIDITÉ

MISE À LA 

TERRE D’UNE 

FICHE À DEUX 

FILS

MISE À LA 

TERRE D’UNE 

FICHE À DEUX 

FILS

BLK

WH

T

GRD

F A N

S W I T C H   B O X

1 2 0  V A C

L I N E  I N

W H T

G R D

2 - W I R E

P L U S 

G R O U N D

B L K

B L K

B L K

FAN

(LOAD)

HOT

(LINE)

NEUT

GRD

W H T

G R N

HUMIDITY

CONTROL

2 - W I R E

P L U S 

G R O U N D

Reviews: