Page 2

MODEL  745BNNT 

3. Set housing 

aside and drive 

nails partially 

into joist at the 

top of both key-

hole marks.

4. Hang housing from 

nails and pound 

nails tight. To en-

sure a noise-free 

mount, pound an-

other nail through 

the top hole of each 

mounting tab.

Existing Construction

2. In  attic,  position  mounting  brackets  against  joist. Trace 

outline of housing on ceiling material.

1.  Choose the location for your fan/light in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

3. Set housing aside and cut ceiling opening slightly larger 

than marked.

INSTALL THE HOUSING

1. Choose the location for your fan in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

2. Position mounting brackets against joist so that bottom  

edge of housing will be flush with finished ceiling.

Additional positioning feature for 5/8”, 1”, &

1-1/4” thick ceiling material:

Holes in corners of housing are labeled with various 

ceiling material thicknesses. Position housing so 

bottom edge of joist is visible through a matched 

set  of  holes. The  housing  is  now  in  the  proper 

position for that ceiling material thickness.

Additional  positioning  feature  for  1/2”  thick 

ceiling material:

Bend two tabs, on side of housing, 90

0

 outward. Lift 

housing until tabs contact underside of joist.

Mark the keyhole slot on both mounting brackets.

New Construction

5/8

1

1-1/4

TAB

HOLES

BOTTOM EDGE OF JOIST

- PLEASE NOTE -

THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 

6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION, 

MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN 

THE SAME MANNER. (Additional framing must be a 2x6 (mini-

mum height), at least 9-inches long.)

4. Place housing in opening so that its bottom edge is flush  

with finished ceiling. Nail to joist through keyhole on both 

sides. To ensure a noise-free installation, drive another nail 

through the top hole of each mounting bracket. 

5. Additional  mounting  holes  are  provided  for  installations 

where access from above is inconvenient or not possible. 

Nail or screw housing directly to joists or framing.

ADDITIONAL

MOUNTING

HOLES

Summary of Contents for 745BNNT

Page 1: ...needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standa...

Page 2: ...housing are labeled with various ceiling material thicknesses Position housing so bottom edge of joist is visible through a matched set of holes The housing is now in the proper position for that cei...

Page 3: ...r wall cap Check damper to make sure that it opens freely Tape all duct connections to make them secure and air tight 1 Wire unit following diagram above Run electrical cable as direct as possible to...

Page 4: ...nt improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to th...

Page 5: ...Aire American Society for Heating RefrigerationandAirConditioningEngineers ASHRAE y los c digos locales ditioning Engineers ASHRAE y las autoridades de los c digos locales 5 Cuando corte o perfore la...

Page 6: ...visible a trav s del conjunto de orificios que coinciden Ahora la cubierta se encuentra en la posici n adecuada para ese espesor del material del cielo raso Caracter stica adicional para la colocaci...

Page 7: ...os ni la parte superior de la unidad despu s de que la instalaci n est terminada DIAGRAMA EL CTRICO N E G R O C O M M V E N T A Z U L N E G R O B L A N C O L A M P B L N C T I E R R A V E N T N E G U...

Page 8: ...mente por otras compa as que no sean Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a...

Reviews: