background image

 

14 

 

 

 
 

f.

 

Click the Advanced Button Under the Optic Tab. 

 

 

 
 
 

Summary of Contents for 3XB

Page 1: ...Nutfield Technology Inc 1 Wall St Suite 113 Hudson NH 03087 USA 91 0017 Rev E 3XB 3 Axis User Manual...

Page 2: ...2 This Page Intentionally Left Blank...

Page 3: ...quirements 17 Environmental 17 Size and Weight 17 11 Outline Drawing 18 12 Service and Support 19 13 Return Procedure 19 14 Contact Information 19 15 Warranty 20 Appendix A CorCalcII Information 21 A...

Page 4: ...s document as well as information included herein without notice Refer to your License Agreement for restrictions on use duplication or disclosure Government users and prime contractors are also gover...

Page 5: ...gh analysis of system safety Key information for this purpose is contained in this manual You must thoroughly familiarize yourself with all this information before proceeding The first consideration i...

Page 6: ...onformance with CFR regulations 1040 10 f 6 which reads as follows A beam attenuator is required on Class II IIIa IIIb and IV laser systems The beam attenuator is a mechanical or electrical device suc...

Page 7: ...possible you should use the available laser s lowest power setting and remote beam sensing techniques Using optical instruments with this product increases eye hazard 5 Safety Precautions During Usage...

Page 8: ...es in front of the X Y scan mirrors in a post objective scanning configuration The expander lens moves linearly along the axis of the beam to correct for focus in real time as a function of an X Y pos...

Page 9: ...acking material and the protective plastic bag d Remove the cover from the 3XB by removing eight 1 5mm button head socket cap screws e The Linear Translator s lens carriage is secured during shipment...

Page 10: ...E CORCALCII TABLES FOUND IN THE APPENDIX NOTE TO GET THE SPECIFIED SPOT SIZE A BEAM EXPANDER MAY BE REQUIRED TO UP COLUMNATE OR DOWN COLUMNATE THE INPUT LASER BEAM 25 PIN XY2 100 INTERFACE 9 PIN POWER...

Page 11: ...and Requested field Typically the Y Radius needs to be 20 larger that the Requested Field value d Click the Validate Value Button If the Requested Field Y Radius ration is acceptable the Outputs valu...

Page 12: ...3 Axis systems are typically shipped with Surfboard or Pipeline laser scan controller hardware The following instructions are for both styles of hardware NOTE 3 Axis systems are designed for specific...

Page 13: ...Input connector 8 6 Start the WaveRunner application a Using the supplied USB cable connect the Scan Controller to the PC b Open the WaveRunner application by Clicking on the WaveRunner icon c When as...

Page 14: ...14 f Click the Advanced Button Under the Optic Tab...

Page 15: ...nfirm its output 8 7 Focus Adjustment a Confirm the Y Radius is set properly Reference the Outline Drawing in Section 11 b In the WaveRunner application draw a small 1cm x 1cm entity in the middle of...

Page 16: ...nob back and forth to achieve the brightest plume of light at the work surface This method of focusing will achieve the most ideal focus taking all system tolerances into consideration The system shou...

Page 17: ...C X DAC CHANNEL X DAC CHANNEL Y DAC CHANNEL Y DAC CHANNEL Z DAC CHANNEL Z DAC CHANNEL STATUS RETURN STATUS RETURN don t connect don t connect don t connect don t connect don t connect don t connect NC...

Page 18: ...r system can run Then select a power supply appropriate for your application Select a high quality power supply with good clean DC outputs Power supplies with excessive ripple or noise will cause scan...

Page 19: ...19 11 0 Outline Drawing...

Page 20: ...ou contact NTI at the address below 13 0 Product Return Procedure If a product is to be returned to the factory please go to our web site http www nutfieldtech com nutfield service asp and fill out th...

Page 21: ...TI representatives attempting to repair or service the product 2 Connecting the product to incompatible equipment 3 Personnel other than NTI representatives modifying the product 4 Scratches and chips...

Page 22: ...22 Appendix A CorCalcII Information A 1 10mm Aperture 266nm NOTE 6 0mm Entrance Beam Required...

Page 23: ...23 A 2 10mm Aperture 355nm NOTE 1 31mm Entrance Beam Required...

Page 24: ...24 A 3 15mm Aperture 532nm NOTE 4 0mm Entrance Beam Required...

Page 25: ...25 A 4 30mm Mirror Aperture 1064nm NOTE 8 10mm Entrance Beam Required...

Page 26: ...26 A 5 30mm Aperture 10 6um NOTE 11 55mm Entrance Beam Required...

Page 27: ...27 A 6 45mm Aperture 10 6um NOTE 14mm Entrance Beam Required...

Page 28: ...28 A 7 30mm Aperture Dual Wavelength 1 of 2 532nm NOTE 6 1mm Entrance Beam Required...

Page 29: ...29 30mm Aperture Dual Wavelength 2 of 2 1064nm NOTE 6 1mm Entrance Beam Required...

Page 30: ...30 A 8 30mm Aperture 355nm NOTE 3 5mm Entrance Beam Required...

Page 31: ...31 A 9 30mm Aperture 532nm NOTE 6 0mm Entrance Beam Required...

Page 32: ...line Controller PC WaveRunner Software XY Z Scan head Laser 15 volt Power Supply 24 volt Power Supply AC AC Shutter or Mounting Plate Shutter uses 15 24 VDC to open USB XY2 100 Data Laser Beam or Fibe...

Reviews: