Operating Manual and Inspection Book
POWER LIFT HL 2.30 NT / HL 2.35 NT / HL 2.40 NT
20100016 OPI
- 34 -
Version 1.1
6.1 Emergency discharge
There is the option of placing the lift into the lowest position with a simple operation.
An emergency discharge can only be done by personnel who are trained to
operate the lift. Follow the conditions to "Lower".
Emergency discharge procedure
• People may not stand in the hazardous area around the lift.
• Slowly pull the operating lever. The lowering process starts immediately. Lowering speed
can be varied by the lever position.
• Always observe the lowering process.
• Lower the lift to the lowest position.
• If required, firstly inform customer service.
• Only operate the lift if it is in seamless condition from a safety point of view again.
6.2 Moving onto an obstacle
If the lifting rails or lifting arms move onto an obstacle due to operator inattention, the lift stops
in place. To remove the object, raise the lift to a height where the object can be removed.
7
Maintenance and care of the lift
Before maintenance, do all preparation work so there is no danger to life or limb or object
damage during maintenance and repair work.
Legal principles: BSV (operating equipment regulation) + BGR500 (Operation of work
equipment).
Value is placed on long lifetimes and safety in the development and production of Nussbaum
products. To guarantee the safety of the operator, product reliability, low running costs, keep
the warranty and also the long-lifetime of the product, proper set up and operation is just as
important as regular maintenance and sufficient care.
Our platforms fulfil or exceed all safety standards of the countries we supply to. For example,
European regulations require a service by qualified experts every 12 months of work of the
platform. To guarantee the largest possible availability and functional capacity of the lift
system, ensure the list of any cleaning, care and maintenance work is done.
After first commissioning the lift is to be serviced at regular intervals of a maximum of one year
by an authorized person according to the following plan. For intensive operation and higher
degree of contamination shorten the service interval.
The complete function of the lift is to be observed during daily use. Customer service must be
informed of any malfunctions.