106
OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL - HYMAX S 3000-S3500-S4000_V1.2_DE-EN-FR-ES-IT
6 Behaviour in cases of error
Defective operational readiness of the lift may be
due to a simple error. Check the system for the list-
ed sources of error.
If the error cannot be removed after an inspection
to the named causes, then inform customer service
or your dealer.
Independent repairs to the lift, espe-
cially on the safety devices, as well
as inspections and repairs to electri-
cal systems are prohibited. Work on
electrical systems may only be done
by electricians.
Problem: Lift can neither be raised nor lowered
possible causes:
Repair:
No power supply pres-
ent
Check power supply
The main switch is not
switched on, or is de-
fective
Check main switch
Defective reverse
switch
Have the reversing switch
checked
Defective fuse
Check fuses
Power line interrupted
Check power lines
Motor has overheated
Let motor cool (cooling
time dependent on am-
bient temperature)
Plug connections not
plugged in or are loose
on the motors
Check the plug connec-
tions on the motors
The platform is not in the
control window
Do a manual equaliza-
tion (see Section 6.4)
Polyflex belt is loose or
defective
Stop the lift and secure
against unauthorised
use. Exchange the poly
-
flex belt and align it. (see
Section 7.3)
Motor defective
Do an emergency dis-
charge (see Section 6.1)
The lift is located in the
lowest position Safety
devices (capture hooks)
are activated
The lift is no longer in the
control range and has
switched off
Lift nut defective
Contact customer ser-
vice
Problem: The lift cannot be raised
possible causes:
Repair:
Only 2 phases active
Do an on-site check with
a qualified electrician
Polyflex belt is loose /
torn
Check / exchange and
align (see Section 7.3)
Lift nut broken, safety
equipment (capture
hook) active, lifting rails
are no longer in their
control range and the
lift has switched off
Stop the lift and secure
against unauthorised
use, contact customer
service
Up Off is active
The lift can only be low-
ered
Problem: The lift cannot be lowered
possible causes:
Repair:
Down Off is active
The lift can only be raised
The lifting arm has
moved onto an obsta-
cle and is out of the
control window
Do a manual equaliza-
tion
Summary of Contents for ATT HYMAX S 3000
Page 17: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 87...
Page 18: ...88 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Page 20: ...90 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Page 21: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 91...
Page 23: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 93...
Page 26: ...96 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Page 27: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 97...
Page 28: ...98 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...
Page 29: ...OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT 99...
Page 30: ...100 OPI_SMART LIFT 2 30 SL 2 35 SL 2 40 SL HYMAX S 3000 S3500 S4000_V1 2_DE EN FR ES IT...