NURIS MAG 550 RWS Operational Manual Download Page 8

08/2022 Rev. 1.3 

 

2.CONNECTION GUIDE 

 

WARNING:

 The installation and first operation of the machine should 

be done by authorized technical personnel. 

2.1. POWER CONNECTION 

 

Figure 2.1. Power Connection 

 

Welder  power  supply  works  with  three  phase  380  Volt 
50Hz utility power. The energy input cable is located at 
the rear of the welder power supply. The yellow-green 
cable (Figure 2.1-PE) should be connected to protective 
earth.  The  remaining  cables  are  the  three  phase 
connections  (Figure  2.1-a).  The  phase  order  is  not 
important, thus, connect the three phase cables to the 
phase supply of the utility. 

2.2. WELDING POWER SUPPLY TO WIRE FEEDER CONNECTION 

 

 

Figure 3.1. Welding power 

supply rear view

 

The welding power supply provides (Figure 3.1) water cooling 
heat  exchange  and  pressure  pump  (Figure  3.1-c),  welding 
current (Figure 3.1-d) and supply current  to the wire feeder 
(Figure  3.1-d).  The  connection  between  these  two  units  is 
made by provided extension cable with welding cable, trigger 
cable,  pressured  water  inlet  and  outlet  hoses  packed  in  a 
flexible hose. 

 

WARNING

: The power supply power must be connected to utility power 

supply through suitable fuse with correct power rating and delay. 

Summary of Contents for MAG 550 RWS

Page 1: ...08 2022 Rev 1 3 OPERATIONAL MANUAL MIG MAG 550 RWS EN...

Page 2: ...ed by Nuri Teknoloji A Reproduction of all or any part of this document is prohibited without the written permission of Nuri Teknoloji A Information and images in this document are subject to change w...

Page 3: ...elding Wire 4 2 5 1 Placing the Wire Spool 4 2 5 2 Wire Feeding System 5 3 Storage and Installation 6 3 1 Storage and Operation Environment 6 3 2 Transportation 6 3 3 Installation 7 4 Operation 7 Tips...

Page 4: ...r filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing Use suitable clothing made from durable flame resistant material to protect you skin and th...

Page 5: ...for calibration and measurement Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may req...

Page 6: ...Open Circuit Voltage V 46 100 Duty A 350 60 Duty A 500 Current Setting A 4x10 Stages Welding wire feed rate m min 2 0 20 0 Welding Wire Diameter Mm 0 80 1 00 1 20 Protection Class IP IP23S Weight kg P...

Page 7: ...Power Supply Power transformer and DC rectifier group that provides the voltage and current required for welding The user parts are a On Off Switch b Welding fine voltage selection switch c Welding c...

Page 8: ...he phase order is not important thus connect the three phase cables to the phase supply of the utility 2 2 WELDING POWER SUPPLY TO WIRE FEEDER CONNECTION Figure 3 1 Welding power supply rear view The...

Page 9: ...gas supply connector Figure 3 1 a Figure 3 2 a Finally connect the torch welding current cable Figure 3 1 d Figure 3 2 d and fix it firmly 2 3 TORCH CONNECTION Connect the torch to the connector Figu...

Page 10: ...es It can damage the machine 2 5 INSTALLING THE WELDING WIRE Before installing the welding wire wear gloves to prevent corrosion of the wire and injury to your hand 2 5 1 PLACING THE WIRE SPOOL The wi...

Page 11: ...ugh the wire channel and brought to the entrance of the wire feeding Figure 5 1 Wire Feed Mechanism The reel screws in Figure 5 2 c are unscrewed and removed After the screws are unscrewed the fixing...

Page 12: ...n the contact nozzle may be encountered If the pressure is low the wire will be loose and the wire feeding will not be homogeneous When adjusting the pressure it is done from loose to tight 3 STORAGE...

Page 13: ...ossible Cables should not be around the operator and scattered around The gas cylinder should be away from the welding area should not get hot and should not be affected by welding sparks The machine...

Page 14: ...n The device does not require maintenance in the specified conditions but some points should be considered for its high efficiency and long lasting operation The periods specified below are the period...

Page 15: ...cleaned with compressed dry air If the machine is used in very dirty environments this process should be done in periods shorter than six months 5 2 NON PERIODIC MAINTENANCE Special care should be gi...

Page 16: ...ong groove was used in the wire feed spool The wire is not placed correctly in the spool groove Suitable welding wire is not used Irregular wire feed The contact part is deformed The wire feed spools...

Page 17: ...Wire feed speed is lower than welding speed Wire diameter is not suitable for the job Porous welding The gas level is too low or too high Splashed droplets accumulate in the gas nozzle and cause insu...

Page 18: ...ANKARA T RK YE Phone 90 312 267 58 60 Web www nuris com tr 8 SERVICE Please refer to www nuris com tr for the most update list of local representatives and authorized technical service lists If there...

Page 19: ...08 2022 Rev 1 3 13 NOTES...

Page 20: ...08 2022 Rev 1 3 14 Nuri Teknoloji A Ahi Evran OSB Mah Bab r ah Cad No 2 06935 Sincan Ankara T rkiye info nuris com tr 90 312 267 58 60 90 312 267 58 59 www nuris com tr...

Page 21: ...MIG MAG 550 User Manual KULLANIM KILAVUZU MIG MAG 550 RWS TR...

Page 22: ...taraf ndan sakl d r Nuri Teknoloji A nin yaz l izni olmadan bu dok man n tamam n n veya herhangi bir b l m n n o alt lmas yasakt r Bu dok man n i inde yer alan bilgi ver g rseller Nuri Teknoloji A ta...

Page 23: ...z Ba lant lar 4 2 5 Kaynak Tel n n ba lant s 4 2 5 1 Tel Sepetinin Yerle tirilmesi 4 2 5 2 Tel S rme Sistemi 5 3 Depolama ve Kurulum 6 3 1 Depolama ve al ma Ortam 6 3 2 Ta ma 6 3 3 Yerle tirme 7 4 Kul...

Page 24: ...lup insan g z ne kal c zarar verir Kaynak yaparken mutlaka ki isel koruyucu donan m kaynak g zl kullan lmal d r Kaynak ark ndan kan nlar insan derisinde yan klara yol a abilir Kaynak yaparken mutlaka...

Page 25: ...ndan kontrol edilmelidir Cihaz n yak n ndan ge en telefon kablolar ve kontrol kablolar Radyo ya da televizyon al c vericileri Bilgisayar ya da bilgisayar tabanl end striyel kontrol sistemleri Emniyet...

Page 26: ...Rejimleri 25 C 60 100 500 A 350 A Ak m Ayar A 4x10 Kademe Kaynak Teli Besleme H z m dk 2 0 20 0 Kaynak Teli ap mm 0 80 1 00 1 20 Koruma S n f IP IP23S A rl k Kg G nitesi 177 Tel Besleme nitesi 23 Mak...

Page 27: ...tesi ve g kayna nitesi ekil 1 MIG MAG 550W RWS n y z G Kayna nitesi Kaynak i in gerekli gerilim ve ak m sa layan g trafosu ve DC do rultucu grubu Kullan c par alar a A ma kapama anahtar b Kaynak ince...

Page 28: ...k lmaks z n ebekenin faz beslemesine ba lan r ekil 2 G Ba lant lar 2 2 G KAYNA I N TES N N TEL BESLEME N TES NE BA LANTILARI ekil 3 1 G nitesinin arka k sm G kayna nitesi ekil 3 1 su so utmal s de i i...

Page 29: ...litleyin Gaz hortumu konekt r n ba lay n ekil 3 1 a ekil 3 2 a Son olarak g ba lant s n ekil 3 1 d ekil 3 2 d ba lay n ve sa lam bir ekilde sabitleyin 2 3 TOR BA LANTISI Tor konekt r n ekil 1 l ba lay...

Page 30: ...ba ka ama lar i in kullanmay n z nk makinada hasara sebebiyet verebilir 2 5 KAYNAK TEL N N BA LANTISI Kaynak teli tak lmadan nce telin korozyona u ramamas n ve elinizde meydana gelebilecek yaralanmala...

Page 31: ...l besleme nitesinin giri ine getirilir ekil 5 1 Tel S rme Mekanizmas ekil 5 2 c deki makara vidalar evrilerek kar l r Vidalar a ld ktan sonra tel s rme makaras n n sabitleme kapa otomatik olarak d er...

Page 32: ...a labilir Tel ayar n n gev ek olma durumunda ise tel s rme homojen ekilde ger ekle meyecektir Bask ayar yap l rken gev ekten s k ya do ru yap l r 3 DEPOLAMA VE KURULUM 3 1 DEPOLAMA VE ALI MA ORTAMI Ma...

Page 33: ...n ayn taraf nda ve operat rden m mk n oldu unca uzakta olmal d r Kablolar operat r n evresinde ve da n k ekilde olmamal d r Gaz t p kaynak yap lan alandan uzakta olmal s nmamal ve kaynak k v lc mlar n...

Page 34: ...taya kabilecek teknik sorunlar reticinin verdi i garantinin kapsam d nda kalabilir Makine sahip oldu u teknik zellikleri ile bu k lavuzda belirtilenlere uygun olarak kullan ld nda nemli bir bak m i le...

Page 35: ...kapaklar a larak buradaki t m enerji ba lant u lar s k t r lmal d r Makinenin kaporta ve di er k s mlar nda ula labilir b t n c vata ve somunlar kontrol edilmeli gev ek olanlar s k lmal d r Makinenin...

Page 36: ...meme t kal d r Kullan lan tel ap na g re tel s rme makaras nda yanl kanal kullan lm t r Tel makara kanal na oturmam t r Uygun kaynak teli kullan lmam t r D zensiz tel s r yor Kontak meme deforme olmu...

Page 37: ...c klar gaz kalkan nozul i inde birikip yetersiz gaz ak na neden olmaktad r Kaynak ortam ndaki hava ak m koruyucu gaz etkisiz k lmaktad r Torcun ucu ile kaynak yap lan malzeme aras ndaki uzakl k fazlad...

Page 38: ...SAN T C A Ankara Organize Sanayi B lgesi Ahi Evran OSB Mah Bab r ah Cad No 2 06935 Sincan ANKARA T RK YE Tel 90 312 267 58 60 Web www nuris com tr 8 TEKN K SERV S Nuri Teknoloji teknik servis a na ula...

Page 39: ...08 2022 Rev 1 0 13 NOTLAR...

Page 40: ...08 2022 Rev 1 0 14 www nuris com tr Nuri Teknoloji A Ahi Evran OSB Mah Bab r ah Cad No 2 06935 Sincan Ankara T rkiye info nuris com tr 90 312 267 58 60 90 312 267 58 59...