6
Welding
In the next screen display, you will be prompted to enter the welding details contained in
the fitting bar code can be entered, by using the keys
and then ENTER
to
confirm.
After completing data entry, the display unit will show the following screen:
After checking the entered data once again, press either ENTER
to confirm or
ESCAPE
to delete the action and return to the previous screen display.
If the fitting connection has not been carried out yet, you will be prompted to carry out
fitting connection in the next screen display.
After connecting the fitting press ENTER
to continue.
The next screen shows a message reminding the operator that, before welding, all the
required preparatory actions must have been completed (scraping and cleaning).
You will also be reminded that, in order to ensure good welding, an alignment clamps
must be used. Press ENTER
to continue or ESCAPE
to return to the previous
screen display.
A summary of the information entered so far will be displayed at this point as shown here
below:
Rated diameter of fitting
to weld
Welding time in
seconds
Welding voltage
in Volts
D = ________
Time = ________
Voltage = ________
ENT= Proceed ESC= Back
Using pipe aligner ?
Y
ENT
No
ESC
Connect fitting
Connect fitting
Press
ENT
Ftng = _________
Type of
Fitting
Fitting
rated
diameter in mm
Fitting
descript.
Fitting symbol
Weld voltage
in Volt
Rated welding time
in seconds
Type= I (COUPLER)
Diam. =
U welding =
t welding =
and in inches
Scraping/Cleaning ?
Y
ENT
No
ESC