15/46
Chart 3
Permissible Mounting Tolerances
Chart 4
* These cumulative tolerances include mounting tolerances and guideway errors during operation�
The mounting tolerances are only valid for one degree of freedom at a time�
4
TECHNICAL DATA
4.1
Mechanical Data
4.1.1 Encoder LIKgo
Parameter
LIK
go
Dimensions of scan head (in mm)
28 x 13 x 7�5
Weight of scan head (w/o cable)
10 g
Traversing speed
depending on auxiliary electronic unit
see Speed Chart
Coorinates for LIKgo scanning heads
Working distance
(air gap between sensor and scale)
1�4 mm
Mounting tolerances / Position deviations*
ΔZ = ±0.2 mm
ΔY = ±0.4 mm
φZ = ±0.2° (±12‘)
φY = ±1.0° (±60‘)
φX = ±1.0° (±60‘)