background image

Operating Switches 

Index page...

Whilst the brush motor is running press the water flow On / Off Button for fluid control (Fig.C), the clean water On / Off  tap must 

be open. 

Ideally set the tap to 450  this enables the cleaning solution to last the same time as a fully-charged battery.

When the Triggers are released the brush motor and the cleaning solution pump will switch off, the vacuum motor will continue 

for 10 seconds.

Press the mode select button to operate the brush only (Fig.D).

The start sequence is required in this mode.

The water flow On / Off button will operate in this mode.

Press the mode select  button again to get vacuum only.

The On / Off Switch and triggers are not required in this mode. (Fig.E)

Press the mode select button to switch this mode off and return to default mode.

The panel if unused will automatically turn off after 60 seconds.

C

D

E

The brush motor will cut out and the brush load light will flash if the brush motor has been overloaded (Fig.F).

Releasing the handle triggers will allow the machine to reset.

Brush Overload

F

IMPORTANT

If the brush motor keeps overloading consider using a different type of brush.

Heavy brush load decreases the available battery run time.

!

!

Fitting Brush - Floor Tool, Filling Machine, Fill Gauge, Moving

Water Flow Adjustment, Raising the Floor Tool

Operating Switches

Draining Top Tank, Draining Bottom Tank, Clean Water Filter

Clean Separator

Changing the Floor Tool Blades

Charging (Cont)

Removing Battery, Fuse, Charging

Summary of Contents for FloorCare TGB 1840

Page 1: ...ining Top Tank Draining Bottom Tank Clean Water Filter Clean Separator Changing the Floor Tool Blades Charging Cont Make sure you read and fully understand your 1840 manual before using the machine PR...

Page 2: ...clean water tank Fitting the Floor Tool Make sure the inspection cap is in place on the fluid pipe Swing the floor tool carrier to the side of the machine Secure to the carrier using the two knobs fi...

Page 3: ...near the base of the handle to raise the floor tool and lock in position On Water Flow Adjustment and Raising the Floor Tool Index page Operating Switches To activate the control panel press the Mode...

Page 4: ...The On Off Switch and triggers are not required in this mode Fig E Press the mode select button to switch this mode off and return to default mode The panel if unused will automatically turn off afte...

Page 5: ...ank if leaving your machine for a extended period The cap has a rubber seal and might require a spanner to remove Regular Maintenance Located under the clean water inlet is the clean water filter Clea...

Page 6: ...the machine Fig 1 2 Remove fixing band holding separator in place Fig 3 Lift off the separator The separator has a sealing rubber which should be examined at every clean down Fig 4 Rinse using clean...

Page 7: ...Fig 1 Refitting the Floor Tool Blades 1 2 3 4 5 Floor Tool Overview 1 Retaining knobs x 4 2 Front blade slotted 3 Blade carrier 4 Rear blade 5 Floor tool main body NOTE The blades are designed to be...

Page 8: ...t you disconnect the battery from the machine If the machine will be standing unused for a period of 30 days or more then batteries must be fully charged Note Batteries should be recharged every three...

Page 9: ...es are discharged the battery charge level meter lights will go out from top to bottom If the battery charge level is allowed to discharge to the point that only one red light remains illuminated the...

Reviews: