Safety Instructions 

 

Carefully read the applicable items of the operating instructions and these safety suggestions 
before using this product. Use extra care to follow the warnings written on the product itself and in 
the operating instructions. Keep the operating instructions and safety suggestions for reference in 
the future.   
 
1.  Power Source. The product should only be connected to a power supply which is described 

either in the operating instructions or in markings on the product. 

 
2.  Power Cord Protection. AC power supply cords should be placed such that no one is likely to 

step on the cords and such that nothing will be placed on or against them. 

 
3.  Periods of Non-use.  If the product is not used for any significant period of time, the product's 

AC power supply cord should be unplugged from the AC outlet. 

 
4.  Foreign Objects and Liquids.  Take care not to allow liquids to spill or objects to fall into any 

openings of the product. 

 
5.  Water or Moisture.  The product should not be used near any water or in moisture. 
 
6.  Heat.  Do not place the product near heat sources such as stoves, heat registers, radiators or 

other heat producing equipment. 

 
7.  Ventilation.  When installing the product, make sure that the product has adequate 

ventilation. Improperly ventilating the product may cause overheating, which may damage the 
product. 

 
8.  Mounting.  The product should only be used with a rack which the manufacturer 

recommends.  The combination of the product and rack should be moved carefully.  Quick 
movements, excessive force or uneven surfaces may overturn the combination which may 
damage the product and rack combination. 

 
9.  Cleaning.  The product should only be cleaned as the manufacturer recommends. 
 
10. Service.  The user should only attempt the limited service or upkeep specifically described in 

the operating instructions for the user.  For any other service required, the product should be 
taken to an authorized service center as described in the operating instructions. 

 
11. Damage to the Product.  Qualified service personnel should service the unit in certain 

situations including without limitation when: 

a.  Liquid has spilled or objects have fallen into the product, 
b.  The product is exposed to water or excessive moisture, 
c.  The AC power supply plug or cord is damaged, 
d.  The product shows an inappropriate change in performance or does not operate 

normally, or 

e.  The enclosure of the product has been damaged. 

 
 
 
 
 
 
 
 
 

Summary of Contents for IDJ LIVE II

Page 1: ...ou are hereby notified that any review dissemination distribution or duplication of this document is strictly prohibited If you are not authorized please contact Numark and destroy all copies of this...

Page 2: ...Manual shall be solely your responsibility and Numark shall have no liability for any such repairs or service work All such service or repairs are performed at the sole risk of the person performing...

Page 3: ...E WITH ANY NUMARK DISTRIBUTOR OR AUTHORIZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR TO BE OR MAKE REPAIRS AS AN AUTHORIZED SERVICE CENTER ALL REPAIRS DONE BY ANY ENTITY OTHER THAN...

Page 4: ...s heat registers radiators or other heat producing equipment 7 Ventilation When installing the product make sure that the product has adequate ventilation Improperly ventilating the product may cause...

Page 5: ...playback pauses playback when pressed again SET CUE Sets Cue point CUE Jumps back to cue point VOLUME Controls audio level on the deck TREBLE Adjusts high end frequencies BASS Adjusts low end frequenc...

Page 6: ...REMOVAL OF BOTTOM CHASSIS Fig 1 A TAKE OUT THE 10 PCS SCREW FROM THE BOTTOM CHASSIS Fig 1 2 REMOVAL OF MAIN PCB ASS Y Fig 2 A TAKE OUT THE 8 PCS KNOB FROM THE CABINET B TAKE OUT THE 7 PCS SCREW FROM...

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ...Insert Card 1 2 OPNK14MAR07 Operation Manual V17 9 1 2 OPNKA9MAR01 Instruction Book 1 2 PE04020060000 Poly Bag 40 200mm 1 2 PE150350BO Poly Bag 150 350mm 1 2 PE230190402B07 Pe Bag 1 2 PE230370402B07...

Page 12: ...C50 119 2 CS105K1003X5R CCAP SMD 1uF 10V 10 0603 X5R 1 C115 2 CS180J5003NPO CCAP SMD 18pF 50V 5 0603 NPO 2 C25 29 2 CS470J5003NPO CCAP SMD 47pF 50V 5 0603 NPO 2 C26 39 2 CS475K1606X7R CCAP SMD 4 7uF...

Page 13: ...R25 36 39 46 47 49 50 52 2 SWDC11B2021431 Switch Rotational Encode 20Pul 1 ENC1 2 TCS106K160B Solid Tantalum Electrolytic 2 C48 49 2 TE622000501 5P CONNECTOR 1 J1 2 TE962542001 Terminal 20P 2 54mm 1 J...

Page 14: ...10V C21 4 7uF 10V D12 GRN R64 56 ohm R59 82 ohm D10 D13 GRN R65 56 ohm R58 82 ohm D11 R16 82 ohm D1 CW 1 2 3 P1 C1 0 1uF CW 1 2 3 P3 C3 0 1uF CW 1 2 3 P5 C7 0 1uF CW 1 2 3 P7 C9 0 1uF CW 1 2 3 P2 C2 0...

Page 15: ...2 3 Q6 MBT4403 1 2 3 Q7 MBT4403 R26 68k R27 10K 1 2 3 Q20 MBT4403 1 2 3 Q21 MBT4403 R28 68k R29 10K C26 47pF C39 47pF R13 560 ohm R15 330 ohm SEN3 RPI 352 R18 22K Q3 MBT4401 R11 10K R5 560 ohm R8 330...

Page 16: ......

Page 17: ......

Page 18: ......

Reviews: