![Nulite New Energy BKDX30-95I/1/S Manual Download Page 24](http://html1.mh-extra.com/html/nulite/new-energy-bkdx30-95i-1-s/new-energy-bkdx30-95i-1-s_manual_1716727024.webp)
23
c
、
The refilling refrigerant quantity subject to the ambient temperature. If you do not meet the required
filling quantity and cannot filling longer, you can turn on the machine, then starting filling
continuously from low pressure side, in the meantime must prevent damage from liquid
refrigerant.
2. Refill the Refrigerant
Connecting the refrigerant bottle at the refrigerant injection needle valve of low pressure side and
connecting the pressure gauge at the low pressure side. Then turn on the machine, filling the refrigerant
into the system slowly and inspect the high and low pressure.
▲Warning: When doing leakage hunting and air tight test, only high pressure nitrogen and
refrigerant is allowed to use, filling oxygen, acetylene or other flammable or toxic gases is strictly
forbidden.
Malfunction analyze and clearing
:
Phenomenon
Reason
Check
Clear
Machine does
not work
Power cut/outage
Measure the voltage
of circuitry
Wait for power resume
The operation
panel has
display, but
machine can not
turn on, key
failure
Operation panel
lines not connected
Check the circuitry
connect
Operation panel
damaged
Substitution method
Replace operation panel
disturbed
Check the source of
interference
Clear the source of
interference
If the line
lengthened by the
non-shielded cable
Replace the line(use
shielded cable)
Low voltage
Check the circuitry
voltage
Replace the line or
increase voltage stabilizer
PCB damaged
Substitution method
Replace PCB
Machine does
not
work
operation panel
no display
Transformer
damaged
Measure with
multi-meter
Replace transformer
Operation panel
lines not connected
well
Check the circuitry
Welding with soldering
iron
Operation panel
damaged
Substitution method
Replace operation panel
PCB damaged
Substitution method
Replace PCB
Summary of Contents for New Energy BKDX30-95I/1/S
Page 4: ...3 BKDX50 200I 1 S BKDX60 220I 1 S BKDX80 280I 1 S...
Page 6: ...5 3 3 BKDX80 280I 1 S 1521 5 1556 5 587 592 620 104 2 964 6 G1 5 G1 5 62 1507 591 8 1052...
Page 11: ...10 2 Connection diagram 1 BKDX30 95I 1 S 2 BKDX50 200I 1 S BKDX60 220I 1 S BKDX80 280I 1 S...
Page 13: ...12 4 Circuit diagram 1 BKDX30 95I 1 S 220V 2 BKDX50 200I 1 S BKDX60 220I 1 S 220V...