7. Pump Assembly

Before using the pump, disassemble and clean according to the instructions in 
sections 5 and 6.

Repeat steps 1-6 for the other side. 

Push the silicone cushion (1), onto the 

opening of the breast shield (2).

Screw the Breast Milk Container (8) 

onto the connection ring (5) on the 

assembled breast shield.

Silicone-gasket (3)

Place the silicone gasket (3) onto the 

breast shield connector (4) and screw the 

breast shield connector clockwise into the 

back of the breast shield (2).  

Push the backflow 

valve (6) into 

the connection 

ring (5) on the 

breast shield (2).

Push the membrane

(7) into the hole of the 

backflow valve (6).

1

2

3

4

5

6

7

Screw the connection ring (5) clockwise 

onto the base of the breast shield (2).

ASSEMBLY INSTRUCTIONS:

NOTE:

 Make sure all pieces are firmly in place to ensure good seals to create 

a vacuum needed to express breast milk.

BREAST SHIELD ASSEMBLY

03_62772_5112_A_DEBP_Booklet_REL_2-19-13_Added pages divisible by 4.indd   9

3/18/2013   2:26:55 PM

Summary of Contents for Expressive 62772

Page 1: ...Breast Pump Extractor de leche el ctrico doble Operating Instructions Instrucciones de operaci n Model 62772 Version 1 03_62772_5112_A_DEBP_Booklet_REL_2 19 13_Added pages divisible by 4 indd 1 3 18...

Page 2: ...03_62772_5112_A_DEBP_Booklet_REL_2 19 13_Added pages divisible by 4 indd 2 3 18 2013 2 26 53 PM...

Page 3: ...ncy of Expressing 12 8 3 Procedure 12 8 4 Milk Quantity 12 8 5 Let Down Reflex 12 9 Storing Feeding Milk 13 9 1 NUK Breast Milk Container 13 9 2 Tips for Handling Breast Milk 13 9 3 Feeding Expressed...

Page 4: ...ing or showering Do not place or store product where it can fall or be pulled into a tub or a sink Do not place in or drop pump unit into water or other liquid Do not reach for this electric breast pu...

Page 5: ...r nipples as this may cause irritation 3 1 Features The NUK Expressive Double Electric Breast Pump is a multi setting breast pump that is designed to mimic natural breastfeeding by offering various co...

Page 6: ...ng 6 Backflow valve 7 Membrane 8 Breast milk container 9 Silicone tubing 10 Tubing connector 11 Connector cap 12 Connector 13 Pump unit 14 Voltage adapter GEO361U 1225 15 Nipple 16 Collar 17 Seal disk...

Page 7: ...d prior to use Insufficient cleaning of the pump and or components can lead to contamination Follow the instructions to ensure proper cleaning NOTE Prior to first use sanitize the breast milk containe...

Page 8: ...ughly before next use 3 Wipe the pump unit 13 with a damp cloth This cleaning is sufficient because the pump unit does not come into direct contact with the breast milk CAUTION Never immerse the pump...

Page 9: ...ieldconnector 4 and screwthe breastshieldconnectorclockwiseintothe backofthebreastshield 2 Push thebackflow valve 6 into theconnection ring 5 onthe breastshield 2 Pushthemembrane 7 intotheholeofthe ba...

Page 10: ...ding to theinstructions in Section 6 1 beforecontinuing to pump 12 11 10 9 3 4 9 10 13 8 Instructions for Use Before using the pump disassemble and clean according to the instructions in sections 5 an...

Page 11: ...ff the pump or breaking suction using your finger CAUTION Do not let breast milk reach or contact the valve when expressing to avoid the risk of contamination or damaging the pump unit Hold the unit a...

Page 12: ...ollowing intervals have proven effective but times may vary according to the individual right 5 7 minutes left 5 7 minutes right 3 5 minutes left 3 5 minutes right 2 3 minutes left 2 3 minutes 8 4 Mil...

Page 13: ...e for storage in the refrigerator or freezer Once the container has been opened the maximum storage time is 12 hours at 39 F 4 C The milk may be thawed out in the container either in the refrigerator...

Page 14: ...rator 39 F or 4 C 5 days Store milk in the back of the main body of the refrigerator Freezer Store milk toward the back of the freezer where temperature is most constant Milk stored for longer duratio...

Page 15: ...with a bottle CARE Disassemble before cleaning Prior to first use sanitize by boiling in water for 5 minutes For day to day cleaning wash with hot water and mild detergent then rinse clean Dishwasher...

Page 16: ...nection ring 5 3 Connection Ring 5 to Breast Shield 2 4 Breast shield 2 to silicone gasket 3 shield connector 4 5 Silicone tubing 9 to tubing connector 10 6 Connector 12 to pump unit 13 Check all part...

Page 17: ...If the pump seems to not be working properly try moving it away from sources such as these This pump may also have problems if the air in your house is dry Please use a humidifier or vaporizer if you...

Page 18: ...ges caused by the breach of any express implied or statutory warranty or condition Except to the extent prohibited by applicable law any implied warranty or condition of merchantability or fitness for...

Page 19: ...r jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusion may not apply...

Page 20: ...edimiento 30 8 4 Cantidad de leche 30 8 5 Reflejo de bajada de leche 31 9 Conservaci n y uso de la leche para alimentar al beb 31 9 1 Envase para leche materna de NUK 31 9 2 Consejos para manipular la...

Page 21: ...productos el ctricos especialmente cuando haya ni os presentes se deben seguir las precauciones de seguridad b sicas Consulte los detalles a continuaci n PELIGRO Para reducir el riesgo de electrocuci...

Page 22: ...ompartir entre madres Cuando el extractor no est en uso aseg rese de que todas las piezas del extractor de leche el ctrico y los accesorios se guarden de manera segura lejos de los ni os Mantenga las...

Page 23: ...cho 3 2 Contraindicaciones En el caso de que se presenten determinados problemas en los pezones inflamaci n heridas abiertas el extractor de leche el ctrico doble Expressive de NUK no debe usarse o so...

Page 24: ...Bot n de velocidad lenta 21 Indicador de succi n 21a Bot n de succi n alta 21b Bot n de succi n baja 22 Bot n de memoria 5 Desarmado del extractor Para lo indicado a continuaci n consulte la secci n V...

Page 25: ...agua durante 5 minutos Tenga cuidado cuando retire los componentes del agua caliente PRECAUCI N Desconecte el adaptador de voltaje 14 del tomacorriente antes de realizar la limpieza 1 Desarme el extr...

Page 26: ...e el extractor y descon ctelo de la fuente de energ a el ctrica Retire y separe los tubos Lave en agua jabonosa tibia y luego enjuague Seque de inmediato y arme el extractor seg n las instrucciones de...

Page 27: ...e leche haci ndolo girar hacia la derecha en la parte posterior del embudo 2 Presione la membrana 7 en el agujero de la v lvula antirreflujo 6 1 2 3 4 5 6 7 Enrosque el anillo de conexi n 5 haci ndolo...

Page 28: ...ediato Limpiar el tubo de acuerdo con las instrucciones en la secci n 6 1 antes continuar para bombear 12 11 10 9 3 4 9 10 13 8 Instrucciones de uso Antes de usar el extractor des rmelo y l mpielo seg...

Page 29: ...s necesidades NOTA Para interrumpir la succi n coloque un dedo entre el pecho y la copa del extractor de leche PRECAUCI N Si por alg n motivo experimenta dolor en el pecho o en el pez n mientras se ex...

Page 30: ...que la ayude si experimenta dificultades para extraerse leche Puede extraerse leche de ambos pechos a la vez extracci n doble o de un solo pecho a la vez extracci n simple Los siguientes intervalos ti...

Page 31: ...tamente puede sellar el envase para leche materna lleno 8 con el collar n 16 y el disco sellador 17 tal como se muestra en la Secci n 4 17b o bien verter el contenido del envase 8 en la bolsa para lec...

Page 32: ...microondas ya que esto destruir valiosos nutrientes y es posible que produzca da os en el material del envase lo que podr a generar un riesgo de explosi n Un calentamiento desparejo tambi n puede gene...

Page 33: ...s intervalos mencionados es seguro pero algunos de los l pidos de la leche sufren una degradaci n que genera una menor calidad Compartimento congelador de un refrigerador 5 F or 15 C 2 semanas Compart...

Page 34: ...mine o corra con un biber n CUIDADOS Desarme el extractor antes de limpiarlo Antes de utilizar el producto por primera vez esteril celo hirvi ndolo en agua durante 5 minutos Para realizar la limpieza...

Page 35: ...5 en copa del extractor de leche 2 4 La copa del extractor de leche 2 en la junta de silicona 3 y en el conector de la copa 4 5 Los tubos de silicona 9 en el conector para tubos 10 6 El conector 12 e...

Page 36: ...art culos para el hogar que emiten ondas electromagn ticas como peque os aparatos y equipos de v deo o televisi n Si la bomba parece no estar funcionando correctamente pruebe si se aleja de fuentes ta...

Page 37: ...amiento no deseado Advertencia Los cambios o las modificaciones a esta unidad que no est n expresamente aprobados por la parte responsable del cumplimiento podr an invalidar la autoridad del usuario p...

Page 38: ...cipio fundamental o de otro tipo ni de cualquier reclamo presentado contra el comprador por cualquier otra parte Algunas provincias estados o jurisdicciones no permiten la exclusi n o limitaci n de da...

Page 39: ...03_62772_5112_A_DEBP_Booklet_REL_2 19 13_Added pages divisible by 4 indd 39 3 18 2013 2 26 59 PM...

Page 40: ...94005112 RevA www NUK USA com 1 888 NUK 1238 03_62772_5112_A_DEBP_Booklet_REL_2 19 13_Added pages divisible by 4 indd 40 3 18 2013 2 26 59 PM...

Reviews: