4.3 Automatic Mode

Use automatic mode if you want the thermostat to follow
a programmed schedule.  At the start of a programmed
period, the temperature will change according to the
schedule you programmed.

To use the automatic mode, press the 

Mode

 button until

the clock icon   appears on the screen. The current
period number will appear. 

Pre-programmed schedule

The following schedule has been programmed at the factory using
the 5 +2 day programming method. One program is used for Monday
to Friday and another program is used for Saturday and Sunday. To
program a new schedule, see section 3.2.

Temporary Bypass

If you modify the temperature (using the 

 buttons) when the ther-

mostat is in automatic mode, the thermostat temporarily bypasses
the current programmed temperature. Your floor will remain at this
temperature for the next two hours. (The clock icon   will flash dur-
ing this time.)  You can cancel the bypass by pressing the 

Mode

 but-

ton.

4.4 Manual Mode

In manual mode, the programmed schedule is not
followed. Use this mode if you wish to set the
temperature manually.

To use the manual mode, press the 

Mode

 button until

the hand icon   appears on the screen and set the
temperature using the 

 buttons.

Your floor will remain at this temperature until the
manual mode is turned off.  To turn manual mode off,
press the 

Mode

 button until the clock icon   appears.

4.5 Off Mode / Vacation Mode

Use the Off mode to cut power to the floor heating
system. This mode is useful in the summer or when
heating is not required for an extended period of time.

To place the thermostat in Off mode, press the 

Mode

button until the message 

OFF

 appears on the screen.

After 5 seconds, the message will disappear and
current time and day will appear.

4.6 Configuring the Thermostat as a Power Regulator

The thermostat can be configured as a power regulator with no tem-
perature feedback (see section 5.1). This feature is useful in any of
the following conditions:

The temperature sensor is not connected to the thermostat.

You wish to control the heating power without accounting for the 
floor temperature.

The temperature sensor is defective.

The thermostat will display the percentage of heating power instead
of displaying the temperature.

NOTE

: When the heating power is displayed instead of the tempera-

ture, 

°F

 or 

°C

 does not appear on the screen.

When configured as a power regulator, the numeric value on the
screen represents the 

percentage

 of the maximum output 

not the

actual temperature

. To set the power, use the 

 buttons.

4.7 Error Codes

The following error codes can appear at the top of the display.

LO

: The measured temperature is below 32°F (0°C).

HI

: The measured temperature is above 140°F (60°C).

E1

: The temperature sensor is defective or not connected.

E2

: The temperature sensor is shorted.

5.1 Configuration settings

To access the configuration settings, simultaneously press and
hold the 

Pgm

 and 

Day

 buttons for 1 second.

To jump from one setting to the next, press the 

Mode

 button.

The configuration settings will appear in the order shown below
(from left to right).

To toggle between the selections, use the 

 buttons.

To exit the configuration settings, press the 

 button.

Periods

Temperature

Start Times

MO

TU

WE

TH

FR

SA

SU

P1

88°F (31°C)

6:00 a.m.

P2

74°F (23.5°C)

9:00 a.m.

--

P3

88°F (31°C)

5:00 p.m.

--

P4

74°F (23.5°C)

11:00 p.m.

r

Configuration

5.

Time 

display

Temperature 

display

Programming 

method

Backlight 

On

Power 

regulator

Early Start

Configuration settings

Selections

NOTE:

The default settings are inside the gray cells.

Time display

12 h

24 h

Temperature display

°F

°C

Programming method 

a

a. This setting specifies the schedule programming method (see 

section 3.2). 

5+2 days

7 days

Backlight On 

b

b. When this setting is set to Y, the screen is permanently backlit. 

When set to N, the backlight is activated for 12 seconds when a 
button is pressed. 

N

Y

Power regulator 

c

c. Enable this setting (Y) to configure the thermostat as a power 

regulator (see section 4.6).

N

Y

Early Start 

d

d. Early Start can be used in Automatic mode only. When this func-

tion is enabled, the thermostat calculates the optimal time to start 
heating in order to obtain the desired temperature by the set time. 
The thermostat re-assesses the start time daily based on the pre-
vious day’s results.