EZ-IN
®
Series
BF Turbine Flowmeter Manual
10
7.
Return the meter to the line, using the body centering rings to align
the meter properly with the interior diameter of the flanges.
Carefully align the flange gaskets to help prevent gasket damage.
Use the spreader nuts, if necessary, to provide room to lower the
meter into the position between the flange gaskets.
8.
Reinstall the bolts that were removed from the flanges when the
meter was taken out of the line.
9.
Loosen the flange spreader nuts until they no longer are engaged.
10.
Tighten the nuts on the flange bolts until they form a seal on the
flange gasket.
11.
Fill the meter with fluid, following the precautions on Page 4.