background image

1

Owner’s Manual

Blood Glucose M

eter

Model: BG4117

Summary of Contents for BG4117 smooze itis

Page 1: ...1 Owner s Manual Blood Glucose Meter Model BG4117...

Page 2: ...2...

Page 3: ...lly Regular monitoring of your blood glucose levels can help you and your doctor gain better control of your diabetes Due to its compact size and easy operation you can use the Blood Glucose Meter to...

Page 4: ...is for reference only 7 Before using this device to test blood glucose read all instructions thoroughly and practice the test Carry out all the quality control checks as directed 8 Keep the device and...

Page 5: ...LOOD SAMPLE 18 Preparing the Puncture Site 18 Alternative Site Testing 20 Performing a Blood Glucose Test 21 METER MEMORY 24 Reviewing test results 24 Reviewing Blood Glucose Day Average Results 25 Do...

Page 6: ...or continue to get results which are higher or lower than usual follow the treatment advice of your healthcare professional Use only fresh whole blood samples to test your blood glucose Using other s...

Page 7: ...use is limited to capillary whole blood testing It should not be used for the diagnosis of diabetes or testing on newborns Professionals may test with capillary and venous blood sample home use is li...

Page 8: ...by pushing this button up Test Slot Insert test strip here to turn the meter on for testing SET Button Enter and con rm the meter settings Data Port Download test results with a cable connection Main...

Page 9: ...lood drop symbol Test result Ketone warning Error Message Memory symbol Control solution mode 1 2 3 5 4 6 7 8 Measuring mode Date Time Day average Reminder alarm Face Low High symbol Measurement unit...

Page 10: ...nto the meter Push it in firmly until it will go no further Absorbent Hole Apply a drop of blood here The blood will be automatically absorbed ATTENTION The front side of test strip should face up whe...

Page 11: ...correct month appears Press SET With the day flashing press M button until the correct day appears Press SET 2 Setting the time format Press and release M button to select the desired time format 12h...

Page 12: ...ss M button to add one minute Hold M button longer to add faster Press SET to confirm and go to the next alarm setting 3 Setting the time With the hour flashing press M button until the correct hour a...

Page 13: ...lly turn on You can press M button to silence the alarm and insert a test strip to begin testing If you do not press M button the meter will beep for 2 minutes then switch off If you do not want to te...

Page 14: ...and Gen THE FOUR MEASURING MODES The meter provides you with four modes for measuring General AC PC and QC MODES General displays as Gen AC PC QC USE WHEN any time of day without regard to time since...

Page 15: ...eeded for a blood glucose test beforehand Do a control solution test when you first receive the meter at least once a week to routinely check the meter and test strips you begin using a new vial of te...

Page 16: ...ger a control solution test WARNING When doing the control solution test you have to mark it so that the test result will NOT be stored in the memory Failure to do so will mix up the blood glucose tes...

Page 17: ...0 the control solution test result will appear on the display Compare this result with the range printed on the test strip vial and it should fall within this range If not please read the instruction...

Page 18: ...nce on the glucose value obtained Blood from a site that has not been rubbed exhibits a measurably different glucose concentration than blood from the finger When the puncture site was rubbed prior to...

Page 19: ...cap for AST Pull the cocking control back until it clicks When lancing the forearm upper arm or hand avoid lancing the areas with obvious veins because of excessive bleeding NOTE Choose a different s...

Page 20: ...sites Thus when testing blood glucose during or immediately after a meal physical exercise or any other event take a blood sample from your finger only We strongly recommend that you perform AST ONLY...

Page 21: ...ood sample Use the pre set lancing device to puncture the desired site After penetration discard the first drop of blood with a clean cotton swab Gently squeeze the punctured area to obtain another dr...

Page 22: ...ount down NEVER try to add more blood to the test strip after the drop of blood has moved away Discard the used test strip and retest with a new one If you have trouble filling the confirmation window...

Page 23: ...meter counts down to 0 This blood glucose result will automatically be stored in the memory 100 mg dL 5 6 mmol L 6 Eject the used test strip and remove the lancet To eject the test strip point the str...

Page 24: ...ewing Test Results 1 Press and release M will appear on the display Press M again and the first reading you see is the last blood glucose result along with date time and the measurement mode 300 mg dL...

Page 25: ...g mode in the order of Gen AC then PC 3 Exit the meter memory Keep pressing the M button and the meter will turn off after displaying the last test result NOTE Any time you wish to exit the memory kee...

Page 26: ...Health Care Software System please visit the nu beca s website www nu beca com 2 Connecting to a personal computer Connect the cable to a USB port on your computer With the meter switched off connect...

Page 27: ...ccurate but it is time to change the batteries The appears with E b Error and low The power is not enough to do a test Please change the batteries immediately Replacing the Battery To replace the batt...

Page 28: ...dust or other contaminants please wash and dry your hands thoroughly before use Cleaning To clean the meter exterior wipe it with a cloth moistened with tap water or a mild cleaning agent then dry the...

Page 29: ...fer to the test strip package insert Important Control Solution Information Use only our control solutions with your meter Do not use the control solution beyond the expiry date or 3 months after firs...

Page 30: ...empt to repair yourself and never try to disassemble the meter under any circumstances Result Readings MESSAGE WHAT IT MEANS 20 mg dL 1 1 mmol L 20 69 mg dL 1 1 3 8 mmol L 240 mg dL 13 3 mmol L 600 mg...

Page 31: ...iately Appears when a used test strip is inserted Repeat with a new test strip Appears when ambient temperature is below system operation range System operation range is 10 C to 40 C 50 F to 104 F Rep...

Page 32: ...32 MESSAGE WHAT IT MEANS WHAT TO DO Problem with the meter Repeat the test with a new test strip If the meter still does not work please contact the customer service for assistance...

Page 33: ...e of blood sample Repeat the test with a new test strip Repeat the test with a new test strip Apply sample only when flashing appears on the display Please contact customer services 3 If the control s...

Page 34: ...mal plasma glucose range for people without diabetes mg dL 100 mg dL 5 6 mmol L 140 mg dL 7 8 mmol L SYMBOL INFORMATION SYMBOL REFERENT REFERENT In vitro diagnostic medical device Do not reuse Consult...

Page 35: ...ction Auto reaction time count down Auto switch off after 3 minutes without action Temperature Warning Operating Condition 10 C to 40 C 50 F to 104 F below 85 R H non condensing Storage Transportation...

Page 36: ...43...

Page 37: ...44...

Page 38: ...45...

Page 39: ...46...

Page 40: ...e use is limited to capillary whole blood testing Storage and Handling IMPORTANT Do not use the test strips if they have expired Test strips expire 3 months after first opening Write the first opening...

Page 41: ...low please contact your healthcare professional Questionable or inconsistent results Please consult your doctor to determine a target range that works best for you STEP 1 Insert the test strip fully...

Page 42: ...mponents Glucose dehydrogenase E Coli 8 Electron shuttle 55 Enzyme protector 8 Non reactive ingredients 29 Additional Information for Healthcare Professionals Always wear gloves and follow your facili...