Test area at the tip of the cassette

Tip cover

Multifunction button for  
priming and releasing 

the finger pricker

Window showing number  
of available lancets

Lever for loading a new  
lancet

Release button for 
opening the cassette compartment cover

Test cassette 
with 50 tests

Rotatable cap for  
setting the penetration 
depth

Welcome to a brand new way of  

blood glucose monitoring!

This Getting Started Guide assists you in using your new Accu-Chek Mobile system quickly 

 

and easily and in experiencing a brand new way of blood glucose monitoring.

This guide provides detailed information about the following topics:

1. When your meter is new 
2. 

Preparing the finger pricker

3. Performing a blood glucose test
4. Loading a new lancet
5. 

What you need to know

This guide does not replace the comprehensive Reference Manual supplied with 
your Accu-Chek Mobile system. Please be sure to observe the safety information in 
the Reference Manual.

Accu-Chek

®

 Mobile

BLOOD GLUCOSE MONITORING SYSTEM

Getting Started 

Guide

Start using the system and experience  
a brand new way of blood glucose monitoring.

PlEASE READ CARE

fully 

BEfoRE uSinG.

05771978001(02)

 – 2010-11   M_V

ersion03_Rev0

Last upda

te:

 2010-06

1. When your meter is new

Open the tip cover completely 

 as far as 

it will go. Only then will you be able to open 
the cassette compartment and to insert the 
test cassette.

Remove the protective films 

D

 from the 

display. Pull the protective strip 

E

 back

-

wards out of the meter to activate the 
batteries. 

Push the release button 

B

 for the cassette 

compartment cover downwards.

Remove a new test cassette from the pack

-

aging and insert it 

. Close the cassette 

compartment cover and the tip cover.

C

©2010 Roche Diagnostics

ACCU-CHEK, ACCU-CHEK MOBILE and FASTCLIX  

are trademarks of Roche. 

M

  Roche Diagnostics GmbH 

Sandhofer Strasse 116  
68305 Mannheim, Germany  

www.accu-chek.com

5.

6.

 

1.

2.

3.

D

4.

Remove the cap 

.

Insert a new lancet drum 

 (white end 

first). You now have 6 new and sterile 

lancets at your disposal.

Place the cap 

 back on again.

Rotate the cap 

D

 of the finger pricker 

until the desired penetration depth is level 
with the indicator. Start with a medium 
penetration depth such as 3.

2. Preparing the finger pricker

The finger pricker is intended for personal use only! 

It may only be used by one person for obtaining blood. There is a risk of infections being transmitted if the finger pricker is 

used by other people, or if healthcare professionals use this finger pricker to obtain blood from more than one person. This finger pricker is therefore not suitable for professional 

use in healthcare facilities or institutions.

onR 1088  –  4all 3951 

V5/1 – gsg_05771978001_02_EnUk_280x420mm – Black

(2010) Herr Broß

 

V5/2 – gsg_05771978001_02_EnUk_280x420mm – Cyan

Prüfmittelnummer 307

 

V5/3 – gsg_05771978001_02_EnUk_280x420mm – Magenta

 

V5/4 – gsg_05771978001_02_EnUk_280x420mm – Yellow

 

V5/5 – gsg_05771978001_02_EnUk_280x420mm – PMS 158 C

Reviews: