18

Use the Memory Function

T

O

 read the measurement value

     

Press the “MEM”  button to view the latest measurement value

     with the measuring date.
     Press the “MEM” button to view the oldest measurement value
     with the measuring date.
     Long press the button and the value quickly changes.

The unit stores the blood pressure and pulse rate in the memory 

after completing a measurement every time. It can automatically 

store 180 sets of measurement values for 2 users (2*90). The 

oldest record is deleted to save the latest measurement value 

when any one user more than 90 sets.

The unit also calculates an average reading based on the values

of the latest 3 times measurement taken.

Please select the user before reading the memory.

To read the average value

     

Press the “MEM” button. The average value symbol will display.

.............................................

the average value of the latest 

3 times measurement taken

Turn to next

The 1st latest 

measurement value

The 2nd latest 

measurement value

The 90th latest 

measurement value

Backward

Forward

To delete the memory value

In the memory reading mode, press the “SET” button for 4-6 seconds,
 the unit will display “           ”

.

Press the “MEM” button and confirm “         ” or “         ”.

If you are sure all the data of corresponding user can be deleted,  press 
the  “START/STOP”  button, all the corresponding user’s data will be 
deleted and the unit will turn off.

19

Use the Memory Function

.........................................

Note: if you have set “          ”, but do not press a button for 2 minutes, 

         the product  will shut off automatically, but the corresponding user’s 

         blood pressure data will not be deleted. The delete operation must 

         be confirmed by user.

BA2115

BA2115

BA2115

Summary of Contents for BA2115

Page 1: ...Model No BA2115 A01 BA2115...

Page 2: ...ols Use 2 Important Safety Notes 3 K now Your Unit 4 5 IHB Introduction 6 Before Taking A Measurement 7 Quick Reference Guide 8 Battery lnstallation Replacement 9 Adjusting Settings 1 To set year 10 2...

Page 3: ...sing measured results may be dangerous Follow the instructions of your healthcare provider Operate the unit only as intended Don t use for any other purpose The unit is intended to use in measuring bl...

Page 4: ...to Air Socket Metal Arm Cuff Warning 1 Do not use rechargeable batteries 2 When using optional AC adapter the AC adapter must comply with the requirements of standard IEC60601 1 3 Optional AC adapter...

Page 5: ...d bathing for 30 minutes before taking a measurement 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or right wrist Always measur...

Page 6: ...ve polarities match the polarities of the battery compartment as indicated Remove the battery cover from the battery compartment Replace the battery cover Press the START STOP button All symbols appea...

Page 7: ...inue with next step Then set the day the time system conversion the hour and the minute by using the same way Continue with step 3 2 To set date and time 10 Press the MEM botton to increase one year P...

Page 8: ...START STOP button to save the current setting and turn off 5 To set user mmHg display kPa display Adjusting Settings 12 Adjusting Settings 13 Press the SET button and the mark of a user will appear wh...

Page 9: ...ug is inserted properly in the main unit 1 15 Proper Use of the Arm Cuff 8 Relax your arm keep the palm upward and the fingers curving naturally then turn on the unit and start to measure Wrap the cuf...

Page 10: ...rts to inflate automatically Press the START STOP button 1 In order to accelerate the measurement time for the systolic pressure more than 180 mmHg press and hold the memory button until the unit infl...

Page 11: ...before reading the memory To read the average value Press the MEM button The average value symbol will display the average value of the latest 3 times measurement taken Turn to next The 1st latest mea...

Page 12: ...ower value represents the blood pressure produced by relaxation of the heart muscle Blood Circulation 21 About Blood Pressure Note When a person s systolic and diastolic pressures fall into different...

Page 13: ...arm and body and keep quiet Error Indicators 22 The following symbol will appear on the display when measuring abnormally 23 Care and Maintenance Do not clean the body and cuff with naphtha thinner or...

Page 14: ...overvoltage II pollution degree 2 The risk of patient and user can be lowered to acceptable level The unit might not meet its performance specification if stored or used outside the following specifie...

Page 15: ...lood Pressure Monitor is intended for use in the electromagnetic environment specified below The customer or the user of Digital Blood Pressure Monitor should assure that it is used in such an environ...

Page 16: ...e does not cover damage incurred by use of the unit not in accordance with the instructions accidental damage or being tampered with or serviced by unauthorized service agents 29 28 EMC Table Recommen...

Reviews: