NuAire SLIMAIRE Installation Manual Download Page 2

2

20. 03. 20. Document Number  671421

Nuaire | 

Western Industrial Estate 

Caerphilly 

CF83 1NA 

|

 

nuaire.co.uk

SLIMAIRE / NA XPC

Installation Manual

1.2 Important Information

This manual contains important information on the safe and 
appropriate assembly, transport, commissioning, operation, 
maintenance, disassembly and simple troubleshooting of the product.

While the product has been manufactured according to the accepted 
rules of current technology, there is still a danger of personal injury or 
damage to equipment if the following general safety instructions and 
the warnings contained in these instructions are not complied with.

Read these instructions completely and thoroughly before 
working with the product.

Keep these instructions in a location where they are accessible 
to all users at all times.

Always include the operating instructions when you pass the 
product on to third parties.

1.3 Personal Protective Equipment

The following minimum Personal Protective Equipment (PPE) is 
recommended when interacting with Nuaire product:

Protective Steel Toed Shoes - 

when handling heavy objects.

 

Full Finger Gloves (Marigold PU800 or equivalent) - 

when 

handling sheet metal components. 

Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent) 

- when conducting light work on the unit requiring tactile 
dexterity. 

Safety Glasses

 - when conducting any cleaning/cutting operation 

or exchanging filters. 

Reusable Half Mask Respirators 

- when replacing filters which 

have been in contact with normal room or environmental air.

Nuaire would always recommend a site specific risk assessment by a 
competent person to determine if any additional PPE is required. 

2.0 INTRODUCTION

These IPX4-Splashproof fans have been specifically designed to 
ventilate small rooms such as toilets, bathrooms, cloakrooms and 
kitchens etc. and can be installed on wall, ceiling or panel.

The units extract directly to outside or through a short length of 
ducting.

3.0  MECHANICAL INSTALLATION

Installation must be completed by competent persons, in accordance 
with good industry practice and should conform to all governing and 
statutory bodies i.e. IEE, CIBSE, etc.

This product should not be used in an ambient temperature higher than 
40°C (104°F) and should not be exposed to atmospheric agents (rain, 
sun, snow, etc.). The product or any part of it should not be placed in 
water or other liquids.

Unit Codes

Operation Type

Weight 

(Kg)

NA100XPC / 
SLIMAIREX100PC

4” Axial continuous low duty with 
boost facility via pull cord / remote 
switch operation.

1.5

NA100XPC-12 / 
SLIMAIRE100XPC-12

12V version of 4” Axial continuous 
low duty with boost facility via pull 
cord / remote switch operation.

0.5

NA150XPC / 
SLIMAIREX150PC

6” Axial continuous low duty with 
boost facility via pull cord / remote 
switch operation.

1.5

3.1 Component Key

1. Front Fixing Screw

2. Front Grille

3. Front Cover

4. Motor Fan Assembly

7

8

6mm dia.

6

5

4

3

2

1

Unit Components

5. Wall Fixing Screws

6. Wall Plug

7. Cable Clamp Screws

8. Cable Clamp

9. Cable Grommet

3.2 Surface Mounting

Remove the fan from the box, taking care to dispose of the packing 
material properly. Check the location of existing wiring for ease of 
connection. For optimum performance site the fan a minimum of 2.3m 
above ground level. 

In the wall or ceiling, cut a hole as follows:

SLIMAIRE / NA 100X fans - 100mm Ø (taking care to allow any 
necessary space for ducting).

SLIMAIRE / NA 150X fans - 150mm Ø - for through wall 
installation.

SLIMAIRE / NA 150X fans - 156mm Ø - for installation using a wall 
liner or telescopic ducting.

For any other wall or ceiling installation check sizes before cutting the 
hole. 

It is the installer's responsibility to use the appropriate core 

cutter to obtain the correct hole diameter.

Dismantle the fan:

Remove the front cover (3) by unscrewing front fixing screw (1).

Using the motor fan assembly (4) of the fan as a template, mark 
the hole drilling positions to fix the fan to the wall or ceiling N.B 
use the holes already knocked out in the top right and bottom left 
corners of the back of the motor fan assembly.

Drill the 6mm dia holes.

Using the wall plugs and long screws provided, fix the motor fan 
assembly (4) to the wall/ceiling.

Before fixing the fan to the wall, 

decide whether to have the cable 

entering the fan through the knocked-out hole on the top of the 
motor fan assembly (4) or whether through the back of the motor fan 
assembly (4).  In the first case the included cable clamp will need to be 
used.  In the second option the cable entry hole will need to be knocked 
out.

Connect to electricity supply via a double pole switch of a suitable size, 
with contact openings of at least 3mm.

Fix back the front cover (3) of the fan.

For window installation (with optional window kit) see instructions on 
page 2.