NuAire OPUS 30 Installation And Maintenance Manual Download Page 1

OPUS 30 and 60

Duct Mounted ('M' range)
Domestic Extract Fans 

Installation   

and Maintenance

NuAire Limited
Western Industrial Estate, Caerphilly,
Mid Glamorgan CF83 1XH
Telephone:  02920 885911
Facsimile: 02920 887033
Email: [email protected]
www.nuaire.co.uk

Leaflet 670445

DECEMBER 2001

Introduction

Nuaire’s OPUS 30 & 60 range of duct mounted domestic extract
fans are designed to extract small volumes of air through 100 mm
dia. pipes, with provision for adding a 50 mm dia. subsidiary unit
to extract air simultaneously from a second room.
Units are available with one or two fans and in two duty sizes
32l/s and 55l/s Inlet is through a 100 mm dia.pipe located on the
front of the unit.
Units can be fitted with a selection of controls which enable
them to be linked to light switches, either directly or through
run-on circuits.

Typical arrangements

Duct mounting - horizontal or vertical*

One room extraction

Two room extraction

Wall mounting

Coding

M

Basic unit with single fan

MS

Single fan unit incorporating a run-on circuit, 
adjustable between 5 and 30 mins.

2MAS

Twin unit incorporating both run-on and fan failure 
detection/change over circuits.

MX

Single fan unit providing continuous low duty running
with boost when room light is switched on. 
(Opus 30 only)

Installation

a)

It is assumed that a solid non reverberant mounting posi-
tion has been prepared inside the duct passage area and the 
necessary ductwork already installed with adequate clear-
ance on the inlet side to allow fitting of the flexible ducting 
supplied with the unit. It is also assumed that the electrical 
connections are in position and if a second room is to be 
ventilated, the ductwork for a subsidiary spigot has been 
made ready.

Contents

Page

Introduction...............................................................1

Arrangements and Codes..........................................1

Installation..................................................................2

Dimensions and Ancillaries.......................................3

Maintenance...............................................................3

Electrical Diagrams............................................. .......4

Certification ...............................................................5

Fig. 1 General view Opus 60M

False ceiling

Subsidiary
inlet

Mounting
bracket

Discharge must be 
uppermost

VERTICAL MOUNTING

Inlet grille

Access panel

Flexible
ducting

IMPORTANT WARNING

Installation and servicing MUST be carried out 

by electrically quaIified personnel. 

The unit MUST BE TOTALLY ISOLATED from the 

electrical supply before removing covers.  

NOTE internal  input socket will be exposed and 

MAY  BE  LIVE with the fan module removed.   

See ‘ISOLATION’ notes.