MAINTENANCE
CLEANING
LIGHT UNIT
Electrically isolate the unit before commencing any
work. Remove the internal finisher by pulling down.
Wash in warm water. The lamp body may be
cleaned using a brush or damp cloth prior to
replacing the finisher.
FAN UNIT
Electrically isolate the unit before commencing any
work. To gain access to both sides of the
impeller/motor it will be necessary to temporarily
remove the unit from the installation. Lightly brush
away any internal build up of dust. Do not use any
solvents or immerse the unit in water. Check the
impeller rotates freely. We suggest the unit is
inspected/cleaned at once yearly in general use.
3 Year Warranty
The three year warranty starts from the date of
delivery and includes parts and labour for the first
year. The labour element is subject to full, free and
safe access to the equipment as recommended by
the CDM regulations.The remaining two years cov-
ers replacement parts only.
NOTE:
Installation & Maintenance of the equipment must
be as directed in the instructions provided with the
unit.
Service
In the event of a breakdown contact our Service
Department. We will be happy to give you more
information .
Telephone: 02920 858585
Facsimile: 02920 858586
NuAire Limited
Western Industrial Estate
Caerphilly, United Kingdom CF83 1XH
Telephone: 029 2088 5911 Facsimile: 029 2088 7033
Email: [email protected] www.nuaire.co.uk
05-10-253 Issue A
WIRING
WARNING!
Isolate electricity supply before
starting work.
●
The unit must be wired and installed in
accordance with IEE or local regulations by a
suitably qualified electrician. The fan must
only be connected using flexible supply cord.
●
The unit is double insulated and does not
require earth connection.
●
The unit must be connected to the double
pole isolating switch having a contact
separation of at least 3mm at each pole and
fitted with a 3A fuse.
●
The power supply unit must not be sited
within reach of a person using a bath or
shower nor within a shower cubicle/
enclosure.
●
The Power supply unit is supplied with flying
leads.The two red 12V leads should be
connected directly to the lamp terminals
within the lamp body (see 5 overleaf).
●
The mains cable from the Power supply
unit should be connected via an RCD
protection device
to a mains voltage
junction box or similar (supplied by others).
See wiring diagram.
●
Connect only one light unit per Power supply
unit.
IMPORTANT!
DO NOT OPERATE THE LIGHT
WITHOUT THE FAN RUNNING.
Specifications
Fan unit:
230V 1ph 50Hz. Watts 23W, IP44.
Light unit:
12V 1ph 50Hz. IP44
Cable size:
1.00mm
2
max. (flexible only).
Lamp:
12V dichroic rated at 20W
36
o
beam angle.
GE Lighting type M269
Lamp replacement
WARNING!
Isolate electricity supply before
starting work.
●
Remove the internal finisher by pulling down.
●
Remove the lamp lens and old lamp by pulling
down.
●
Fit lamp by pushing up into the lamp holder.
●
Push up lamp lens and internal finisher.
DIMENSIONS
Side
Ø118mm
87mm
Front
NEONAIRE
LIGHT UNIT
Ø180mm
41.5mm
NEONAIRE
FAN UNIT
FAN MOUNTING
122mm
26mm
56mm
71mm
Ø115.5mm
Surface cable entry
110mm
Front
Side
N
L
Switch
(not supplied)
Junction Box
(not supplied)
RCD Trip device
(not supplied)
Light
Power supply
unit
Neonaire
Light unit
230V Induct Fan
230V
12V
12V
50Hz
N
SL
1
2
L
Double pole
isolating switch
(not supplied)
230V
~ 50Hz
Mains
Supply
Fuse
(not supplied)
N
SL
L
3
4
Red
Br
o
w
n
Blue
Red
NOTE:
An RCD trip device must be
included in the mains 230V
supply to the power supply unit
if the unit is fitted in zone 1 as
defined in IEE regulations.