
MAINTENANCE
CLEANING
LIGHT UNIT
Electrically isolate the unit before com-
mencing any work.
Remove the internal finisher
by pulling down. Wash in warm water. The lamp
body may be cleaned using a brush or damp cloth
prior to replacing the finisher.
FAN UNIT
Electrically isolate the unit before com-
mencing any work.
Dust, fluff etc. if allowed, will build up on the motor
and / or impellers, shortening the life of the unit
and, in severe cases, lead to overheating of the
motors. It is therefore strongly recommended that
all units are fitted with inlet filters to prevent con-
tamination of motor/fan assembly. The unit should
also be inspected and cleaned at least once every
six months.
Procedure
At all times take care not to damage, distort or dis-
turb the balance of the impellers.
Separate the two halves of the unit by undoing the
screws on the black half of the unit and disengage
the two off location tags.
Remove the electronic module.
Spring aside the two clips and remove the fan mod-
ule. Visually inspect all parts, replace any damaged
items.
Using a soft brush or dry cloth remove any dust
and dirt from the fan mobile. Stubborn dirt may be
removed by careful use of a soft scraper.
Re-fit fan and electronic control module. Ensure
that the control module is fully engaged with sock-
et. Before refitting cover switch on the unit
momentarily at the isolator and check that the
green running light is illuminated before replacing
black cover and securing with the screws.
Note:
For maintenance purposes, only the black cover must
be removed.
3 Year Warranty
The three year warranty starts from the date of
delivery and includes parts and labour for the first
year. The labour element is subject to full, free and
safe access to the equipment as recommended by
the CDM regulations. The remaining two years
covers replacement parts only.
NOTE:
Installation & Maintenance of the equipment must
be as directed in the instructions provided with the
unit.
Service
In the event of a breakdown contact our Service
Department. We will be happy to give you more
information.
Telephone: 02920 858585
Facsimile: 02920 8585
NuAire Limited
Western Industrial Estate
Caerphilly, United Kingdom CF83 1XH
Telephone: 029 2088 5911 Facsimile: 029 2088 7033
Email: [email protected] www.nuaire.co.uk
05-10-2540. Issue A
WIRING
WARNING!
Isolate electricity supply before
starting work.
●
The unit must be wired and installed in
accordance with IEE or local regulations by a
suitably qualified electrician. The fan must
only be connected using flexible supply cord.
●
The unit must be connected to the double
pole isolating switch having a contact
separation of at least 3mm at each pole and
fitted with a 3A fuse.
●
The power supply unit must not be sited
within reach of a person using a bath or
shower nor within a shower cubicle/
enclosure.
●
The Power supply unit is supplied with flying
leads.The two red 12V leads should be
connected directly to the lamp terminals
within the lamp body (see 5 overleaf).
●
The mains cable from the Power supply
unit should be connected via an RCD
protection device
to a mains voltage
junction box or similar (supplied by others).
See wiring diagram.
●
Connect only one light unit per Power supply
unit.
Specifications
Fan unit:
230V 1ph 50Hz. Watts 23W, IP44.
Light unit:
12V 1ph 50Hz. IP44
Cable size:
1.00mm
2
max. (flexible only).
Lamp:
12V dichroic rated at 20W
36
o
beam angle.
GE Lighting type M269
Lamp replacement
WARNING!
Isolate electricity supply before
starting work.
●
Remove the internal finisher by pulling down.
●
Remove the lamp lens and old lamp by pulling
down.
●
Fit lamp by pushing up into the lamp holder.
●
Push up lamp lens and internal finisher.
DIMENSIONS
Side
Ø118mm
87mm
Front
NEONAIRE
LIGHT UNIT
Ø180mm
41.5mm
GENIE/TOPS
FAN UNIT
90o BEND
Side
Ø119mm
115mm
59mm
55.5mm
200
150 ctrs
98mm
OD
125
130 ctrs
175
55
Front View
Side View
N
L
Switch
(not supplied)
Junction Box
(not supplied)
RCD Trip device
(not supplied)
Light
Power supply
unit
Neonaire
Light unit
230V
Induct
Fan
230V
12V
12V
50Hz
N
SL
1
2
L
Double pole
isolating switch
(not supplied)
230V
~ 50Hz
Mains
Supply
Fuse
(not supplied)
2
L
N
1
3
4
Red
Br
o
w
n
Blue
Red
3
NOTE:
An RCD trip device must be
included in the mains 230V
supply to the power supply unit
if the unit is fitted in zone 1 as
defined in IEE regulations.