NuAire MRXBOXAB-ECO-LP2-C Installation And Maintenance Manual Download Page 6

6

nuaire.co.uk 

029 2085 8400

20. 08. 19. Document Number  671887

I

nstallation and Maintenance

MRXBOXAB-ECO-LP2-C Remote Commissioning MVHR 

6.0 DIMENSIONS (mm) OPPOSITE HAND CONFIGURATION

7.0 DUCTING ARRANGEMENTS, OPPOSITE HAND CONFIGURATION

688 Hole Centres

View from top (A)

700

View from control side

900 

37

1

857

885 hole centres 

121

End view

200

67

(B)

(A)

600 

Spigot 2.

View from underside with cover removed (B)

Air

Supply 

Spigot 3.

Extract 

Air

Spigot 4.

Air

Exhaust 

Spigot 1.

Air

250

Intake 

Heat 

exchanger

Bypass 

chamber

Supply

fan

Extract

fan

21.5mm condensate pipe

Drip tray 

Wire

frame

filter

Wire

frame

filter

Bypass 

4.

damper 

1.

2.

3.

735 (Filter access distance)

Removable

access

filter

Removable

access

filter

69

97

342

Access 
Requirements

Supply air to 

lounge via

in ceilings.

Air Valve  

Extract air from 

kitchen via 

in ceilings.

Air Valve  

Supply air to 

bedrooms via

in ceilings.

MVHR-DRAIN 

Air Valve  

condensate drain,

running to SVP.

mounted unit.

Nuaire ceiling void 

Extract air from 

bathroom via 

in ceilings.

Air Valve  

Exhaust air from 

kitchen/bathroom to 

outside via air brick.

Supply and extract 

ducts from external 

air bricks to the unit 

needs to be insulated.

Top of ceiling void.

Minimum distance as 

specified in Building 

Regulations. 

Intake air from 

outside via air brick.

Figure 9. Dimensions & Access Requirements (Opposite Hand Unit)

Figure 10. Typical Ducted Arrangement for a Void Mounted Unit (Opposite Hand) Using Rectangular Ducting and Ceiling Air Valves

Summary of Contents for MRXBOXAB-ECO-LP2-C

Page 1: ...mum contact separation of 3mm in accordance with latest edition of the wiring regulations This unit must be earthed Ducting must be securely fixed with screws to the spigot to prevent access to live p...

Page 2: ...all statutory governing regulations Beware of sharp edges on unit when handling ensure appropriate PPE is used All mains wiring must be in accordance with the current I E E Regulations or the appropri...

Page 3: ...epth on the pipe and check that the pipe section to be jointed is free of any surface damage which may affect the joint seal 3 Unscrew the cap from the MVHR DRAIN outlet and slide the cap and rubber s...

Page 4: ...rate from Table 1 For sanitary accommodation only as an alternative the purge ventilation provisions given in ADF 2010 can be used where security is not an issue In this case minimum high extract rat...

Page 5: ...2 3 735 Filter access distance Removable access filter Removable access filter 69 97 342 Access Requirements Supply air to lounge via in ceilings Air Valve Extract air from kitchen via in ceilings Ai...

Page 6: ...3 735 Filter access distance Removable access filter Removable access filter 69 97 342 Access Requirements Supply air to lounge via in ceilings Air Valve Extract air from kitchen via in ceilings Air V...

Page 7: ...oses only as the connections above are factory fitted Connection to Remote Fail Indicator Ref MRXBOX95 RFI optional Fuse 2A MAINS 230V 50Hz light Room Light switch Double Pole N L 3 Pole isolator Kitc...

Page 8: ...N The status of the unit is indicated by a series of LED s on the control box cover The variants are listed below 10 1 Integral automatic HX bypass AB units only Intake and extract temperatures are mo...

Page 9: ...only for the remaining 4 years This warranty is conditional on planned maintenance being undertaken This warranty is void if the equipment is modified without authorisation is incorrectly applied misu...

Reviews: