ES-TC Timeclock

Designed to be compatible with the

Ecosmart system, this timeclock is 

supplied with a pre-plugged, 10 metre

length of communications cable. Note:

longer lengths are available if required.

The unit operates with Safe Extra Low

Voltage (SELV) with power supplied from

the fan unit via the communications cable.

The ES-TC timeclock will switch the 

system on and off at pre-determined

times set by the user. 

This digital timeclock will override the

user control for effective on/off 

operation.

The timeclock operates on Safe Extra

Low Voltage and is powered from the fan

control module. The connection is made

into any ‘NET’ socket on the fans integral

control module.

Parts check list: 

l

1 off ES-TC Timeclock.

l

1 off 10 metre length of plugged 

SELV cable.

Handling

Always handle the controls carefully to

avoid damage and distortion.

Installation

The installation must be carried out by

competent personnel in accordance with

the appropriate authority and conforming

to all statutory and governing regulations

i.e. IEE, CIBSE, CCHSE, HVCA etc.

The unit is suitable for indoor use only.

Mount on a secure, vibration free vertical

surface away from any direct source of

heat and areas where it would be 

subjected to waterspray. The maximum

permissible ambient temperature is 40

o

C.

a) Removing the mounting cradle from

the backing plate on the rear of the 

control.

Insert your thumb in a cable

entry hole and lift sharply. See figures 1

and 2. Offer the cradle to the selected

mounting position, mark and fix.

b)

Draw approx. 75mm of data cable

through the cradle and plug in to the rear

socket of the control, paying particular

attention to plug/socket colour code for

correct orientation.

c)

Clip the control into the cradle.

d) Removing the control module from

the backing plate.

Press firmly on either

side of the control, strain sharply across

to the right and lift the left hand side of

the control module out. See figure 3.

The matched frequency inverter will have

been pre programmed to suit the user

control prior to delivery. 

Install the inverter in accordance with 

the instructions provided with it.

Connect the other end of the data cable

to the inverter, remove the plug from the

data cable and terminate, following the

instructions provided with the inverter.

Unit dimensions & weights

Drill pattern & fixing detail

Data cable installation

A 4-core 10 metre length of SELV data

cable is used to connect devices. Longer

lengths are available if required. 

Do not run data cable in the same conduit

as the mains cables and ensure there is a

50mm separation between the data cable

and other cables. The maximum cable run

between any two devices is 300m when

it is installed in accordance with the

instructions.

ES-TC 
TIMECLOCK

Extra Low Voltage User Control

97 mm fixing ctrs

14

7

 C

o

v

e

r

 o

p

e

n

5

4

Cable entry

Cable 

entry

Drill 2 holes in wall 

surface for 6mm dia.

wallplugs (supplied).

163 mm overall

Cover

Figure 5.

Figure 4.

 

 

 

 

  

 

 

Remove mounting cradle from backing plate  

to affix to selected mounting position

Power

Statu

s

Front of Control being removed  

from backing plate

 

 

 

 

 

  

 

 

 

 

 

Place thumb in the cable entry  

hole on the back side of the  

cradle and pull sharply up

Figure 1. 

Figure 2.

Figure 3.

Nuaire Limited

Western Industrial Estate  Caerphilly  United Kingdom  CF83 1NA  

T: 029 2085 8400  F: 029 2085 8444  E: [email protected]  W: www.nuaire.co.uk

03. 07. 15. Leaflet Number 671162

A

C

B

The EMC Directive 

2004/108/EC     

The Low Voltage 

directive 

2006/95/EC