NuAire eco dri Installation Manual Download Page 2

Adjusting the Temperature Set Point

The occupier will normally require the heater to activate when

the loft temperature falls below a predetermined point.

We recommend that the temperature set point be set at 10

o

C. 

Electrical Connection

The heater is rated at 500 watts and should be connected to 

a suitably rated power supply via a switched fused spur 

(by others).

Remove the cover and connect mains to L/N/E as shown in 

figure 4.

Communication Connection

a) Drimaster 

link 

-  

should be fitted at J5. Figure 4.

b)  For  Drimaster 2000 and Drimaster 365 - 

wire sensor

cable to terminal J3 on heater. See figure 5.

c) Dri-Ecosmart and Sunwarm - 

connect heater net 

connector to any of the four net connections on the main 

unit control. See figure 4.

Maintenance

The unit does not require any maintenance. However, for 

optimum performance, it is advisable to remove any 

accumulated dust with a low power vacuum cleaner.

NOTE: Installation and Maintenance of the equipment must 

be as directed in the instructions provided with the unit.

Warranty

The 3 year warranty starts from the day of delivery and

includes parts and labour for the first year.

The remaining 2 years covers replacement parts only. 

This warranty is conditional on planned maintenance 

being undertaken.

Service Enquiries

Nuaire can assist you in all aspects of service. Our service

department will be happy to provide any assistance required,

initially by telephone and If necessary arrange for an engineer

to call.

Telephone 029 2085 8585

Fax 029 2085 8586

Installation and Maintenance

ECO Dri Heater

Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and 

dimensions of equipment and the right is reserved to make such changes without prior notice.

To Drimaster
2000 and
Drimaster 365

Figure 4. 

Figure 5.

2

Leaflet Number 671195 February 2011

Ensure the fan is running before operating the heater.

If the heater should trip out the power should be isolated for

several minutes to allow the unit to reset the thermal trip.